ERMA SSI 9005 User manual

SSI 9005
Digital Panel Meter
for Absolute Encoders with Synchron-Serial-Interface
Instruction Manual

Warranty
For delivered products our "Allgemeine Lieferungs- und Zahlungsbedingungen" are effective. In no event
we or our suppliers shall be liable for any other damages whatsoever (including, without limitation, dama-
ges for loss of business profits, business interruption or other pecuniary loss) arising out of or inability to
use this product.
All our products are warranted against defective material and workmanship for a period of two (2) years
from date of delivery. If it is necessary to return the product, the sender is responsible for shipping charges,
freight, insurance and proper packaging to prevent breakage in transit. The warranty does not apply to de-
fects resulting from action of the buyer, such as mishandling, improper interfacing, operation outside of de-
sign limits, improper repair or unauthorized modification.
Trademarks
All trademarks that are named or portrayed in the text are registered trademarks of its owner.

CONTENTS
1. Description ...........................5
2. Safety instructions .......................6
2.1. Symbol explanation ....................6
3. Mounting ............................7
3.1. Place of operation .....................7
3.2. Mounting of signal converter................7
4. Electrical connections .....................8
4.1. General instructions ....................8
4.2. Hints against noisy environment..............8
4.3. Connection and pin assignment ..............9
4.4. Connection of absolute encoder..............10
4.5. Connection of digital user inputs .............10
4.6. Connection of alarm outputs (relay) ............10
4.7. Connection of analog output................11
4.8. Connection of RS 485 interface ..............11
4.9. Connection of power supply voltage............11
4.9.1. Supply voltage 18 ... 36 V DC ...........11
5. Startup procedure .......................12
6. Pushbuttons- and LED-functions ...............13
6.1. Function of buttons and LEDs ...............13
7. Modes ..............................14
7.1. Operation level.......................14
7.2. Access-code level .....................15
7.3. Programming level.....................16
8. Procedure of programming ..................17
8.1. Changing or controlling parameters ............17
8.2. Overview of the programming levels ...........18
8.3. Programming level for configuration P-00 .........19
8.3.1. Scaling the display range .............21
8.4. Programming level of alarms P-02 ............22
ERMA-Electronic GmbH 3

8.4.1. Alarm output functions...............23
8.4.2. Alarm high setpoint ................24
8.4.3. Alarm low setpoint .................24
8.5. Programming level for analog output P-03 ........25
8.5.1. Scaling of the analog output............25
8.5.2. Analog output at failure Indication ........26
8.5.3. Analog output at overflow resp. underflow ....26
8.6. Programming level of serial interface P-04 ........27
8.6.1. Transmission-Mode ................27
8.7. Programming quick reference ...............28
9. Software functions .......................30
9.1. Master/Slave-Mode ....................30
9.2. Zero point adjustment ...................30
9.2.1. Zero point adjustment by pressing button .....30
9.2.2. Zero point adjustment by offset value .......31
9.3. Incremental measurement .................32
9.4. Direction of rotation ....................32
9.5. MIN/MAX value detection .................32
9.6. Hold function ........................33
9.7. Removing bits of the encoder value ............33
9.8. Display test ........................35
9.9. Main reset .........................35
10. Error codes ...........................35
10.1. Encoder not connected “Err01" ..............35
10.2. Waiting for data input “Err02" ...............35
10.3. External clock frequency too high “ERR03" ........35
11. Technical Specifications ....................36
11.1. Electrical datas.......................36
11.2. Mechanical datas .....................37
11.3. Environmental conditions .................37
12. Ordering Information ......................37
13. Notes ..............................38
4ERMA-Electronic GmbH

1. Description
The digital converter Model SSI 9005 is an instrument to convert datas of absolute
encoders with Synchronous-Serial-Interface (SSI) in an analog output signal. Si-
multaneous, it can carried out an alarm point controlling.
Standard hardware
•isolated analog output 0 - 10 V, 2 - 10 V, 0 - 20 mA, 4 - 20 mA
•two relay alarm outputs
•two programmable digital input channels
•three programmable pushbuttons
Standard software
•Encoder adjustments
•Adjustable for encoder with 9-32 bits
•Bit programming for fir-tree data format
•Scaling factor
•Zero point adjustment
•Direction of rotation
•Offset value
•Incremental measurement
•Display test and display hold (Latch)
•MIN/MAX value detection
•Auto-Reset for MIN/MAX value
•Set point editing during normal measurement
Following options are available
•RS485 interface
ERMA-Electronic GmbH 5
1. Description
Stand : 19.09.2006
All details are subject to change

2. Safety instructions
This instrument is produced in accordance with Class II of IEC 348 and VDE 0411.
When delivered the instrument has been tested to meet all functions described. Befo-
re installing the instrument please read the mounting and servicing instructions.
We have no liability or responsibility to customer or any other person or entity with re-
spect to any liability, loss or damage caused or alleged to be caused directly or
indirectly by equipment or software sold or furnished by us. Read the installation in-
struction carefully. No liability will be assumed for any damage caused by improper
installation.
Inspect the instrument module carton for obvious damage. Be shure there are no
shipping and handing damages on the module before processing. Do not apply po-
wer to the instrument if it has been damaged.
ERMA’s warranty does not apply to defects resulting from action of the buyer, such as
mishandling, improper interfacing, operation outside of design limits, improper repair
or unauthorized modifications.
2.1. Symbol explanation
Caution: Will be used at dangerous for life and health !
Attention: Will cause damage
Instruction: If not noticed, trouble may occur
Tip: Useful hints for better operation
6ERMA-Electronic GmbH
2. Safety instructions
Caution Attention Instruction Tip

3. Mounting
3.1. Place of operation
Attention must be payed to the protection against humidity, dust and high temperatu-
res at the place of operation.
3.2. Mounting of signal converter
•through simple snap up at 35 mm rail (DIN EN 50022)
ERMA-Electronic GmbH 7
3. Mounting
105
70
110
PP
LED3LED3
LED2LED2
LED1LED1
ERMA-METER

4. Electrical connections
4.1. General instructions
•It is forbidden to plug or unplug connectors with voltage applied
•Attach input and output wires to the connectors only without voltages
applied
•Cords must be provided with sleeves
•Attention must be paid that the power supply voltage applied will
agree with voltage noticed at the name plate.
•The instrument has no power-on switch, so it will be in operation as
soon as the power is connected.
4.2. Hints against noisy environment
All inputs and outputs are protected against noisy environment and high voltage
spikes. Nevertheless the location should be selected to ensure that no capacitive or
inductive interference can have an effect on the instrument or the connection lines.
It is advisable:
•To use shielded cables.
•The wiring of shields and ground (0V) should be star-shaped.
•The distance to interference sources should be as long as possible. If
necessary, protective screen or metal enclosures must be provided.
•Coils of relays must be supplied with filters.
•Parallel wiring of input signals and AC power lines should be avoi-
ded.
8ERMA-Electronic GmbH
4. Electrical connections

4.3. Connection and pin assignment
All inputs and outputs are connectors, designed as plug-in screw terminals.
Pin assignment:
1Power supply DC (+) 14 SSI-Signalinput, Clock (+)
2 Power supply DC (-) 15 SSI-Signalinput, Clock (-)
3Ground connection 16 SSI-Signalinput, Data (+)
4Analog output 0/2-10 V (+) 17 SSI-Signalinput, Data (-)
5Analog output 0/4-20 mA (+) 18 SSI-Signalinput, GND (0 V)
6Analog output, GND (-) 19 Ground connection
7Option RS485, A (+) 20 - n.c.
8 Option RS485, B (-) 23 n.c.
9Option RS485, GND 24 Digital user input 1
10/11 Alarm (relay) output 1 25 Digital user input 2
12/13 Alarm (relay) output 2 26 Digital GND
ERMA-Electronic GmbH 9
4. Electrical connections
PP
LED3LED3
LED2LED2
LED1LED1
ERMA-METER
1122557788996644331111 1212
1010 1313
1414
15152626 2525 2424 2323 2222 2121 2020 1919 1818 1717 1616
analog output alarm 1 alarm 2
+-
signal input
digital
inputs
RS 485
n.c.

4.4. Connection of absolute encoder
4.5. Connection of digital user inputs
Digital input 1
•active => Connecting Screw Terminal 24 to 26
•Connecting to Ground, low active
Digital input 2
•active => Connecting Screw Terminal 25 to 26
•Connecting to Ground, low-active
4.6. Connection of alarm outputs (relay)
10 ERMA-Electronic GmbH
4. Electrical connections
alarm 1 alarm 2
Encoder
Clock -
Clock +
Data+
Data-
(GND)
Table of contents