Table of Contents
1 BRIEF Introduction........................................................................................................................... - 1 -
1.1 Measuring parameters .............................................................................................................. - 1 -
1.2 Features and functions.............................................................................................................. - 1 -
1.3 Features of measuring parameters............................................................................................. - 2 -
2 Technical Specifications ................................................................................................................... - 2 -
2.1 Parameter specifications ........................................................................................................... - 2 -
2.2 Other specifications .................................................................................................................. - 4 -
3 Instrument Desctiption.................................................................................................................... - 4 -
3.1 LCD display ............................................................................................................................... - 4 -
3.2 Keypad functions ...................................................................................................................... - 5 -
3.3 Meter sockets ........................................................................................................................... - 6 -
3.4 Display mode and other functions ............................................................................................. - 6 -
3.5 Other functions......................................................................................................................... - 7 -
4 pH Measurement ............................................................................................................................ - 8 -
4.1 pH electrode information .......................................................................................................... - 8 -
4.2 Calibration solution and calibration mode.................................................................................. - 8 -
4.3 pH measurement ...................................................................................................................... - 9 -
4.4 pH test.................................................................................................................................... - 10 -
4.5 Information regarding pH calibration and measurement .......................................................... - 10 -
4.6 Customized calibration (take 1.60pH & 6.50pH as example)...................................................... - 11 -
4.7 Notes regarding customized calibration ................................................................................... - 11 -
4.8 Self-diagnosis information....................................................................................................... - 11 -
4.9 Maintenance of the pH Electrode ............................................................................................ - 12 -
5 mV and ORP Measurement............................................................................................................ - 13 -
5.1 mV measurement ................................................................................................................... - 14 -
5.2 ORP measurement.................................................................................................................. - 14 -
6 Conductivity Measurement............................................................................................................ - 15 -
6.1 Conductivity electrode information ......................................................................................... - 15 -
6.2 Information about conductivity calibration.............................................................................. - 16 -
6.3 Conductivity calibration (take 1413 μS/cm as an example) ....................................................... - 17 -