3
Specifications
3
Weight: 3lbs (1.4kg)
Temperature Sensors: 3 Integrated Analog Sensors (for external probe)
Temperature Thresholds: 4 per sensor
Multi-purpose User Analogs: 3
Analog Input Range: -90 to +90 VDC (or 4-20mA)
Analog Thresholds: 4 per analog channel
BatteryCell Inputs: 24
Analog Input Range: 2V cell: 0 - 3VDC
12Vcell: 0 - 17VDC
48Vcell: 0 - 58VDC
Analog Thresholds: 4 battery cell
Note: Cell inputs require the correct battery harness installed that is appropriate for the cell voltage you
are monitoring. Damage could occur without the external harness and could void your warranty.
Contact DPS Telecom support team if you require assistance regarding the battery harness options.
Protocols: SNMPv1, SNMPv2c, DCPx, TELNET, HTTP, Email
Dimensions: 1.7" H x 8.1" W x 7.1" D
(4.4 cm x 20.6 cm x 18.2 cm)
Mounting: 19" or 23" rack or wall mount
Power Input: -48VDC
Current Draw: 50mA@ -48VDC
Fuse: 1/2 Amp GMT Fuse
Interfaces: 1 RJ45 10BaseT Ethernet port
1 DB9 front-panel craft port
3 - 1/8 Stereo connector for external temperature probes
RS232 Serial Port
12 - 4-pin analog connectors for battery cell input
Visual Interface: 10 Front Panel LEDs
4 Back Panel LED
Operating Temperature: 32°–140° F (0°–60° C)
Operating Humidity: 0%–95% non-condensing
RoHS: 5/6