Desoutter MULTI Quick start guide

Printed Matter No. 6159929540_EN
Issue No. 03
Date 03/2023
MULTI - Modular Spindle Solution
Installation and Upgrade Manual
WARNING
Read all safety warnings and instructions
Failure to follow the safety warnings and instructions may result in
electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference
www.desouttertools.com

6159929540 / v.03 2 / 64 03/2023
Table of Contents
Introduction............................................................................................................................................4
About Installation and Upgrade manual ..........................................................................................4
Warranty..........................................................................................................................................4
Quick Start .............................................................................................................................................5
Read before installing......................................................................................................................5
System description ..........................................................................................................................5
Overview ..............................................................................................................................5
Technical data......................................................................................................................8
Installation restrictions .......................................................................................................................10
Checking the line voltage ..............................................................................................................10
Connecting to factory power network ............................................................................................10
Permanently connected equipment...............................................................................................11
Overall dimensions........................................................................................................................11
Hardware installation ..........................................................................................................................13
Installing the system......................................................................................................................13
Recommended installation order .......................................................................................13
Mounting the aluminum profiles .........................................................................................13
Opening M-POWERBOX ...................................................................................................15
Mounting M-POWERBOX ..................................................................................................15
Connecting the power input ...............................................................................................15
Closing M-POWERBOX.....................................................................................................18
Connecting the power distribution cable to the mains........................................................18
Mounting M-MODURACK ..................................................................................................18
Managing multiple racks ....................................................................................................20
Mounting M-SAFETYBOX..................................................................................................21
Mounting M-DRIVE ............................................................................................................21
Mounting M-PROTECTRACK ............................................................................................21
Mounting CONNECT..........................................................................................................22
Installing cord fixtured tools................................................................................................23
Connecting the system..................................................................................................................25
M-SAFETYBOX - bottom panel .........................................................................................25
Connecting the Emergency stop ........................................................................................25
Connecting CONNECT to M-SAFETYBOX .......................................................................26
Connecting cord fixtured tools............................................................................................27
Connecting a computer to CONNECT ...............................................................................29
Powering on ..................................................................................................................................29
Powering off M-POWERBOX.............................................................................................29
Powering on the distribution circuit-breaker .......................................................................29
Powering on M-POWERBOX and CONNECT ...................................................................30
Reporting LEDs at powering on .........................................................................................30
Software installation ...........................................................................................................................31
Read before installing software .....................................................................................................31
Location of Desoutter programs.........................................................................................31
Computer minimum requirements......................................................................................31

03/2023 3 / 64 6159929540 / v.03
Installing CVI CONFIG ..................................................................................................................31
Test and validate installation .............................................................................................................32
Testing and validating ...................................................................................................................32
Setting up MULTI in CVI CONFIG .....................................................................................32
Setting up the tools ............................................................................................................34
Configuring a Pset..............................................................................................................34
Updating CONNECT ..........................................................................................................35
Testing a Pset with CVI MONITOR....................................................................................35
Activating the Emergency stop system ..............................................................................36
Hardware upgrade ...............................................................................................................................37
Upgrading CONNECT ...................................................................................................................37
Checking the existing system firmware..............................................................................37
Checking the firmware version with CVIMONITOR ...........................................................37
Upgrading the firmware......................................................................................................37
Software upgrade ................................................................................................................................38
Upgrading software .......................................................................................................................38
References ...........................................................................................................................................39
Logical input ..................................................................................................................................39
General commands............................................................................................................39
Tool commands..................................................................................................................41
Pset commands .................................................................................................................42
Assembly Process commands ...........................................................................................42
External input .....................................................................................................................43
Socket tray .........................................................................................................................43
Customized Protocol commands .......................................................................................43
CVILOGIX ..........................................................................................................................44
List of user infos ............................................................................................................................44
List of user infos related to the system...............................................................................44
List of user infos related to the tools ..................................................................................53
Logical output ................................................................................................................................56
General status....................................................................................................................56
Tool status..........................................................................................................................57
Pset status .........................................................................................................................59
Assemby Process status....................................................................................................61
External output ...................................................................................................................62
Socket tray .........................................................................................................................62
Customized Protocol Status...............................................................................................62
CVILOGIX ..........................................................................................................................63
Miscellaneous ....................................................................................................................63

6159929540 / v.03 4 / 64 03/2023
Introduction
About Installation and Upgrade manual
This manual describes how to install and upgrade MULTI system.
Desoutter should not be held responsible for any injury, accident or damage which may be the consequence of an in-
correct installation, modification or start-up, or a use out of the intended use of Desoutter products, by the customer
or a third party.
Before starting, you must read and understand the safety instructions given in the booklet supplied in the pack-
aging box of products (printed matter: 6159929530).
At the end of the installation, the tool status is "Tool locked", awaiting the selection of the tightening operation
named "Pset".
To test and validate that the system is properly working, follow the procedure described in this manual.
Warranty
• Product warranty will expire 12 months after the product is first taken into use, but will in any case expire at the
latest 13 months after delivery.
• Normal wear and tear on parts is not included within the warranty.
• Normal wear and tear is that which requires a part change or other adjustment/overhaul during standard tools
maintenance typical for that period (expressed in time, operation hours or otherwise).
• The product warranty relies on the correct use, maintenance, and repair of the tool and its component parts.
• Damage to parts that occurs as a result of inadequate maintenance or performed by parties other than Desoutter
or their Certified Service Partners during the warranty period is not covered by the warranty.
• To avoid damage or destruction of tool parts, service the tool according to the recommended maintenance sched-
ules and follow the correct instructions.
• Warranty repairs are only performed in Desoutter workshops or by Certified Service Partners.
Desoutter offers extended warranty and state of the art preventive maintenance through its Tool Care contracts. For
further information contact your local Service representative.
For electrical motors:
• Warranty will only apply when the electric motor has not been opened.

03/2023 5 / 64 6159929540 / v.03
Quick Start
The following sections describe how to install your MULTI system
Read before installing
WARNING Read all safety warnings and all instructions. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
Refer to the "Safety Information" booklet provided in the product box.
WARNING All locally legislated safety rules regarding installation, operation and maintenance shall be
respected at all times.
System description
Overview
Example of installation with CONNECT-W and 10 M-DRIVE.
MULTI system is composed of the following items.
1. MULTI is providing the power supply, the connectivity and the safety devices.
2. The frame is equipped with cord fixtured tools designed by Desoutter.
3. CONNECT is managing the tightening units and all data communications.
4. CVI CONFIG is the software dedicated to set up the system.
Description
MULTI is composed of the following elements:

6159929540 / v.03 6 / 64 03/2023
12
3
4
5
6
1 M-POWERBOX 2 M-SAFETYBOX
3 M-DRIVE 4 M-MODURACK2,
M-MODURACK3
or M-MODURACK5
5 M-RACKPLUG 6 M-PROTECTRACK
• M-POWERBOX provides the power supply to the system. It is connected to the mains via the power distribution
cable (not supplied)
• M-SAFETYBOX provides the connectivity and the safety devices.
• M-DRIVE are powered by M-MODURACK. The drives are powering the cord fixtured tools.
• M-RACKPLUG is used to close the last M-MODURACK.
WARNING Installation
►It is compulsory to place a M-PROTECTRACK if there is no M-DRIVE in a slot (empty slot)
►It is compulsory to place a M-RACKPLUG to close the last M-MODURACK before powering on the M-
POWERBOX
In case of using a minimum of 1 (one) spindle in the range of EB12 motors:
- EFM80-700 - 6151662320
- EFM80-950 - 6151662330
- EFM106-1400 - 6151662340
- EFM106-1900 - 6151662350
Each M-POWERBOX must not power more than 6 (six) M-DRIVES
CONNECT
Both models (CONNECT-W and CONNECT-X) can manage up to 4 MULTI tightening units and 2 wireless tighten-
ing units.
In MULTI system, CONNECT is managing the M-DRIVE(s) via Ethernet.
CONNECT can be powered by M-SAFETYBOX.
CONNECT can be placed on the rail on the left of M-POWERBOX or anywhere else as long as it is connected to
MULTI via an Ethernet cable.
Refer to the Product Instructions of CONNECT (printed matter: 6159924300) directly available from this link:
CONNECT Online Documentation

03/2023 7 / 64 6159929540 / v.03
CVI CONFIG
CVI CONFIG is designed to set your systems point to point or via network with an intuitive and guided interface.
From your computer, you can set up Desoutter tightening products, cord tools, cordless tools, WI-FI cordless tools,
accessories, peripherals and tightening processes.
You can also configure Fieldbus, protocols, backup and you can send data to CVINET WEB for traceability.
Cord fixtured tools
Each cord fixtured tool is powered by a M-DRIVE.
Tools must be clamped on a frame.
The frame where tools are clamped must be properly grounded and connected to the M-POWERBOX before
powering on the system.
Ordering information
M-POWERBOX 6159327510
M-SAFETYBOX 6159327520
M-DRIVE 6159327630
M-PROTECTRACK 6159327550
M-MODURACK2 6159327560
M-MODURACK3 6159327570
M-MODURACK5 6159327580
M-RACKPLUG 6159327590
CONNECT-X 6159327220
CONNECT-W 6159327230
Tool models can be different according to the installation type.
Contact your Desoutter representative to get more information and support.
Connection cables for M-SAFETYBOX
Always make sure to use the cables supplied with the system.

6159929540 / v.03 8 / 64 03/2023
Power cables to connect M-SAFETYBOX to CONNECT
Length (m) Length (ft) Part number
1 3.28 6159177530
30 98.42 6159177540
Ethernet cables to connect M-SAFETYBOX to CONNECT
Length (m) Length (ft) Part number
1 3.28 6159177560
30 98.42 6159177570
M12/open - Emergency stop cable
Length (m) Length (ft) Part number
10 32.8 6159177660
Tool cables
Length (m) Length (ft) Part number
2.5 8.20 6159176510
5 16.0 6159176520
10 32.8 6159176540
15 49.2 6159176550
Tool extension cables
Length (m) Length (ft) Part number
8 26.2 6159175810
16 52.5 6159175840
32 105 6159175870
Technical data
Power supply
Overvoltage equipment category II
Electrical Equipment Class 1
Power supply
Input voltage (V) 3 ~ 380-480 (phase to phase)
Frequency (Hz) 50/60
Power supply fluctuations must not exceed +/- 10% of the nominal voltage
Power consumption
Item A
M-POWERBOX 32
M-SAFETYBOX 2
M-MODURACK (used here as a cable) 32
M-DRIVE 3

03/2023 9 / 64 6159929540 / v.03
Output voltage
Item
M-POWERBOX 380 – 480 V ~
M-SAFETYBOX
24 V
M-MODURACK -
M-DRIVE 3 ~ 520 V ~
15 V
Storage and use conditions
Storage temperature -20 to +70 °C (-4 to +158 F)
Operating temperature 0 to 40 °C (32 to 104 F)
Storage humidity 0-95 % RH (non-condensing)
Operating humidity 0-90 % RH (non-condensing)
Altitude up to 2000 m (6562 feet)
Usable in Pollution degree 2 environment
Indoor use only
IP54 only in use conditions
Weight
kg lb
M-POWERBOX 6.0 13.22
M-SAFETYBOX 2.5 5.51
M-MODURACK2 0.5 1.10
M-MODURACK3 0.7 1.54
M-MODURACK5 1.22 2.20
M-DRIVE 3.5 7.72
M-PROTECTRACK 2.2 4.85
Additional accessories
These additional accessories must be ordered separately
Accessories Part number
CONNECT-X 6159327220
CONNECT-W 6159327230
Support for CONNECT 6159327620
M12/M12 CONNECT/M-SAFETYBOX Power cable 1M 6159177530
M12/M12 CONNECT/M-SAFETYBOX Power cable 30M 6159177540
RJ45/M12X CONNECT/M-SAFETYBOX Ethernet cable 1M 6159177560
RJ45/M12X CONNECT/M-SAFETYBOX Ethernet cable 30M 6159177570
M12X/M12X M-SAFETYBOX Power cable 1M 6159177600
M12X/M12X M-SAFETYBOX Power cable 30M 6159177610
M12/M12 M-SAFETYBOX Emergency stop cable 1M 6159177630

6159929540 / v.03 10 / 64 03/2023
Installation restrictions
Checking the line voltage
WARNING Risk Of Electric Shock
Only qualified and trained operators should install, adjust or use this equipment.
Before connecting the Power Box to the main supply, check that the line voltage is appropriate.
Line voltage 3~ 380-480 V ~
The symbol ~ means "alternating current".
Connecting to factory power network
Recommended overcurrent protection: circuit breaker 32A curve D - Fuses not recommended
Only for factory power system based on “wYe” (Y) connected transformer as follow
- Earthing schemes:
• TT + Ground Fault interruptor (GFI) 300 mA or higher
• TNC
• TNS
This manual suits for next models
8
Table of contents
Other Desoutter Industrial Equipment manuals

Desoutter
Desoutter C Series User manual

Desoutter
Desoutter B Series User manual

Desoutter
Desoutter Industrial Tools DTH TWIN Series User manual

Desoutter
Desoutter Industrial Tools SD Series Operating instructions

Desoutter
Desoutter D53-25 X/Y CANopen User manual

Desoutter
Desoutter Industrial Tools SD Series Operating instructions

Desoutter
Desoutter DJS FOR DST AND PST 2Nm SOFT User manual

Desoutter
Desoutter CP4444 User manual

Desoutter
Desoutter 115DFL User manual

Desoutter
Desoutter Industrial Tools Balancer 12ZG User manual