Cal Test Electronics CT4447 Series User manual

User Manual
CT4447 Series
30 MHz High-Voltage Differential
Probes, cTUVus Listed

2CT4447 Series High-Voltage Differential Probes User Manual
Notices
Copywrite © 2022 Cal Test Electronics, Inc. All rights reserved.
Unauthorized duplication of this documentation material is strictly prohibited. Users are permitted to
duplicate and distribute this documentation for internal educational purposes only. Cal Test Electronics
is governed by United States and international copywrite laws.
Made in Taiwan
User Manual Part Number
451-043-001 Rev. C
Available in electronic format only
Published by:
Cal Test Electronics, Inc.
22820 Savi Ranch Parkway
Yorba Linda, CA 92887 USA
Warranty
LIMITED TWO-YEAR WARRANTY
Cal Test Electronics, Inc warrants these products to be free from defective material or workmanship for
a period of 2 years from the date of original purchase. Under this warranty, Cal Test Electronics, Inc
is limited to repairing this product when returned to the factory, shipping charges prepaid, within the
warranty period.
Units returned to Cal Test Electronics, Inc that have been subject to abuse, misuse, damage, or
accident, or have been connected, installed, or adjusted contrary to the instructions furnished by Cal
Test Electronics, Inc, or that have been repaired by unauthorized persons, will not be covered by this
warranty.
Cal Test Electronics, Inc reserves the right to discontinue models, change specications, price, or
design of this device at any time without notice and without incurring any obligation whatsoever.
The purchaser agrees to assume all liabilities for any damages and/or bodily injury which may result
from the use or misuse of this device by the purchaser, his employees, or agents.
THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS OR WARRANTIES EXPRESSED
OR IMPLIED AND NO AGENT OR REPRESENTATIVE OF CAL TEST ELECTRONICS, INC IS
AUTHORIZED TO ASSUME ANY OTHER OBLIGATION IN CONNECTION WITH THE SALE AND
PURCHASE OF THIS DEVICE.

3CT4447 Series High-Voltage Differential Probes User Manual
Contents
Notices......................................................2
User Manual Part Number .......................................2
Warranty.....................................................2
Contents ....................................................3
Compliance Information .........................................5
EMC ........................................................5
EC Declaration of Conformity - EMC..............................5
Safety .......................................................5
EC Declaration of Conformity - Low Voltage........................5
U.S. and Canadian Recognized Agency Certication.................5
Environmental ................................................5
Restriction of Hazardous Substances (RoHS 2) .....................5
Product End-of-Life Handling ...................................6
Terms & Symbols..............................................7
Terms .......................................................7
Symbols .....................................................7
Safety Information .............................................8
Safety Notices ................................................8
IEC Measurement Category & Pollution Degree Denitions .............11
Introduction ..................................................12
Overview ....................................................12
Supplied Accessories...........................................14
Setting Up and Using the Probe...................................15
Setting Up....................................................15
Using .......................................................15
Specications & Characteristics...................................17
Performance Plots .............................................19
Performance Verication ........................................22
Required Equipment............................................22
Test Procedures...............................................23
Test Setup..................................................23
Gain Accuracy...............................................24
Rise Time ..................................................25

4CT4447 Series High-Voltage Differential Probes User Manual
Cleaning.....................................................26
China RoHS 2 ................................................27
Hazardous Substances Disclosure Table ...........................27

5CT4447 Series High-Voltage Differential Probes User Manual
Compliance Information
EMC
EC Declaration of Conformity - EMC
Compliance was demonstrated to the following specications listed in the Ofcial Journal of the
European Communities: EMC Directive 2014/30/EU.
EN 61326-1:2013. Electrical equipment for measurement, control and laboratory use-
EMC requirements Part 1: General requirements.
Safety
EC Declaration of Conformity - Low Voltage
Compliance was demonstrated to the following specication as listed in the Ofcial Journal of the
European Communities: Low Voltage Directive: 2014/35/EU.
EN 61010-1:2010/AMD:2016. Safety requirements for electrical equipment for
measurement, control and laboratory use - Part 031: General requirements
EN 61010-031:2015 Ed 2.0. Safety requirements for electrical equipment for
measurement, control and laboratory use - Part 031: Safety requirements for hand-
held probe assemblies for electrical measurement and test.
U.S. and Canadian Recognized Agency Certication
The probe is has been certied by TUV Rheinland Taiwan Ltd. (TUV) to conform to the following safety
standard and bears the cTUVus mark.
IEC 61010-031:2015 Ed. 2.0. Safety requirements for electrical equipment for
measurement, control and laboratory use - Part 031: Safety requirements for hand-
held probe assemblies for electrical measurement and test.
Environmental
Restriction of Hazardous Substances (RoHS 2)
The product and its accessories conform to the Directive 2011/65/EU (RoHS 2) on the restriction of the
use of certain hazardous substances in electrical and electronic equipment, inclusive of any modication
and addendum to said Directive.
EN ISO 63000:2018 Technical documentation for the assessment of electrical and
electronic products with respect to the restriction of hazardous substances.
China RoHS 2 refers to the Ministry of Industry and Information Technology Order No.
32, effective July 1, 2015. See “Hazardous Substances Disclosure Table” on page
27.

6CT4447 Series High-Voltage Differential Probes User Manual
Product End-of-Life Handling
The equipment may contain substances that could be harmful to the environment or human health
if improperly handled at the product’s end of life. To avoid release of such substances into the
environment and to reduce the use of natural resources, we encourage you to recycle this product to an
appropriate system that will ensure that most of the materials are reused or recycled appropriately.
This product is subject to Directive 2012/19/EU of the European Parliament and the
Council of the European Union on waste electrical and electronic equipment (WEEE),
and in jurisdictions adopting that Directive, is marked as being put on the market after
August 13, 2005, and should not be disposed of as unsorted municipal waste. Please
utilize your local WEEE collection facilities in the disposition of this product.

7CT4447 Series High-Voltage Differential Probes User Manual
Terms & Symbols
The following terms, symbols, and de nitions, individually or combination may appear on the product or
in this user manual.
Terms
A caution statement calls attention to an operating procedure, practice, or condition,
which, if not followed correctly, could result in damage to or destruction of parts or the
entire product.
Une mise en garde attire l’attention sur une procédure, une pratique ou une condition
d’utilisation qui, si elles ne sont pas suivies correctement, pourraient endommager ou
détruire une partie du produit ou le produit entier.
A warning statement calls attention to an operating procedure, practice, or condition,
which, if not followed correctly, could result in injury or death to personnel.
Un avertissement attire l’attention sur une procédure, pratique ou condition de
fonctionnement qui, si elles ne sont pas suivies correctement, pourraient entraîner des
blessures, voire la mort de l’utilisateur.
A note statement calls attention to an operating procedure, practice, or condition,
which, should be noted before proceeding.
Un énoncé de note attire l’attention sur une procédure, une pratique ou une condition
d’exploitation, qui doit être notée avant de continuer.
Symbols
CAUTION – Statements or instructions that must be consulted in order to nd
out the nature of the potential hazard and any actions which must be taken.
WARNING - HIGH VOLTAGE - possibility of electric shock.
Earth (ground) TERMINAL - Refer to the instructions accompanying this sym-
bol in this manual.
The Conformitè Europëenne (CE) mark is the European Union’s (EU) man-
datory conformity marking for regulating the goods sold within the European
Economic Area (EEA).
The cTUVus mark certi es that a product complies with North American electri-
cal and safety standards, including those written by Underwriters Laboratories
and the CSA Group (CSA).
CAUTION
MISE EN GARDE
WARNING
AVERTISSEMENT
NOTE
REMARQUE
Earth (ground) TERMINAL - Refer to the instructions accompanying this sym-

8 CT4447 Series High-Voltage Differential Probes User Manual
Safety Information
Safety Notices
These test probes have been designed and tested in accordance with accepted industry and has
been supplied is a safe condition. Before applying power, verify that the correct safety precautions are
taken (see the following warnings). In addition, note the external markings on the instrument that are
described under “Symbols” on page 7.
Throughout this manual and speci cally in this section, there are warnings, cautions, and notes that you
must follow to ensure safe operation and to maintain the probe in a safe condition.
To avoid personal injury and to prevent re or damage to the probe and the products
connected to it, review and comply with the following safety Warning and Cautions.
Pour éviter les blessures corporelles et éviter un incendie ou des dommages à la
sonde et aux produits qui y sont connectés, lisez et respectez les avertissements et
mises en garde de sécurité suivants.
Do not use your probe in a manner not speci ed by the manufacturer. Be aware, that
if used in a manner not speci ed by the manufacturer, the protection provided by the
probe assembly may be impaired.
N’utilisez pas votre sonde d’une manière non spéci ée par le fabricant. Sachez que
s’il est utilisé d’une manière non spéci ée par le fabricant, la protection fournie par
l’ensemble de sonde peut être altérée.
The Probe Must be Grounded.
Before making connections to the input leads of the probe, ensure that the output
BNC connector is attached to the BNC input channel of the oscilloscope AND the
oscilloscope is properly grounded.
La sonde doit être mise à la terre.
Avant d’effectuer les connexions aux ls d’entrée de la sonde, assurez-vous que le
connecteur BNC de sortie est connecté au canal d’entrée BNC de l’oscilloscope ET
que l’oscilloscope est correctement mis à la terre.
Connect and Disconnect the Probe Properly.
Connect the probe to the oscilloscope before connecting the probe inputs to the circuit
under test. Disconnect the probe inputs from the circuit under test before disconnecting
the probe from the oscilloscope.
Connectez et déconnectez correctement la sonde.
Connectez la sonde à l’oscilloscope avant de connecter les entrées de la sonde
au circuit à tester. Déconnectez les entrées de la sonde du circuit à tester avant de
déconnecter la sonde de l’oscilloscope.
Observe Maximum Working Voltages.
To avoid injury, do not use the probes above 1000 Vrms in a CAT III environment
between each input lead and earth or between the two input leads.
Do not operate the CT4447-2 probe above 1000 Vrms mains isolated (200x
WARNING
AVERTISSEMENT
WARNING
AVERTISSEMENT
WARNING
AVERTISSEMENT
WARNING
AVERTISSEMENT
WARNING

9CT4447 Series High-Voltage Differential Probes User Manual
attenuation) between the two input leads and above 1000 Vrms mains isolated (both
20x and 200x attenuation) between each input lead and earth.
Respecter les tensions de fonctionnement maximales.
Pour éviter les blessures, n’utilisez pas les sondes au-dessus de 1000 Vrms dans
un environnement CAT III entre chaque l d’entrée et la terre ou entre les deux ls
d’entrée.
Ne pas faire fonctionner la sonde CT4447-2 au-dessus de 1000 Vrms isolé du secteur
(200x atténuation) entre les deux câbles d’entrée et au-dessus de 1000 Vrms isolé du
secteur (à la fois 20x et 200x atténuation) entre chaque câble d’entrée et la terre.
Do not attempt internal service or adjustment.
Do not install substitute parts or perform unauthorized modications to the probe.
Service should be carried out by Cal Test authorized service personnel. For any
service needs, contact Cal Test Electronics.
Ne tentez pas d’entretien ou de réglage interne.
N’installez pas de pièces de rechange et n’effectuez pas de modications non
autorisées sur la sonde. Le service doit être effectué par le personnel de service
autorisé par Cal Test. Pour tout besoin de service, contactez Cal Test Electronics.
Do Not Operate Without Covers. To avoid electrical shock, or re hazard, do not
operate these probes with cover removed.
Ne pas utiliser sans couvercles. Pour éviter les chocs électriques ou les risques
d’incendie, n’utilisez pas ces sondes avec le couvercle retiré.
Avoid Exposed Circuit. To avoid injury, remove jewelry such as rings, watches, and
other metallic objects. Do not touch exposed connections and components when
power is present.
Évitez les circuits exposés. Pour éviter les blessures, retirez les bijoux tels que
bagues, montres et autres objets métalliques. Ne touchez pas les connexions et les
composants exposés lorsque l’alimentation est présente.
Use Proper Power Source. To ensure these probes function well, use either four fresh
AA batteries or the supplied USB power cord.
Utilisez une source d’alimentation appropriée. Pour garantir le bon fonctionnement
de ces sondes, utilisez soit quatre piles AA neuves, soit le cordon d’alimentation USB
fourni.
For Indoor Use Only. To avoid electric shock, injury, or re hazard, do not operate this
probe in wet or damp conditions or in an explosive atmosphere.
Pour une utilisation en intérieur uniquement. Pour éviter les chocs électriques, les
blessures ou les risques d’incendie, n’utilisez pas cette sonde dans des conditions
humides ou humides ou dans une atmosphère explosive.
AVERTISSEMENT
WARNING
AVERTISSEMENT
WARNING
AVERTISSEMENT
WARNING
AVERTISSEMENT
WARNING
AVERTISSEMENT
WARNING
AVERTISSEMENT

10 CT4447 Series High-Voltage Differential Probes User Manual
Periodically inspect your probe and probe wires to check for any damage. Do Not
Operate with Visible or Suspected Failures. If you suspect there is damage, have it
inspected by Cal Test authorized service personnel.
Inspectez périodiquement votre sonde et ses ls pour vérier qu’ils ne sont pas
endommagés. Ne pas utiliser avec des défaillances visibles ou suspectées. Si vous
pensez qu’il y a des dommages, faites-le inspecter par le personnel de service autorisé
de Cal Test.
When it is likely that the ground protection is impaired, you must make the instrument
inoperative and secure it against any unintended operation.
Lorsqu’il est probable que la protection au sol soit altérée, vous devez rendre
l’instrument inopérant et le sécuriser contre tout fonctionnement intempestif.
The probe and its cables are sensitive parts and therefore, you should be careful not
to damage them though excessive bending or pulling. Avoid any mechanical shocks to
the probe to guarantee accurate performance and protection.
La sonde et ses câbles sont des pièces sensibles et, par conséquent, vous devez faire
attention à ne pas les endommager en les pliant ou en tirant excessivement. Évitez
tout choc mécanique sur la sonde pour garantir des performances et une protection
précises.
WARNING
AVERTISSEMENT
WARNING
AVERTISSEMENT
CAUTION
MISE EN GARDE
This manual suits for next models
2
Table of contents
Other Cal Test Electronics Measuring Instrument manuals

Cal Test Electronics
Cal Test Electronics CT4197 User manual

Cal Test Electronics
Cal Test Electronics CT4071 User manual

Cal Test Electronics
Cal Test Electronics CT4076-NA User manual

Cal Test Electronics
Cal Test Electronics CT3688A User manual

Cal Test Electronics
Cal Test Electronics CT4422 User manual

Cal Test Electronics
Cal Test Electronics CT4028 User manual

Cal Test Electronics
Cal Test Electronics CT4196 User manual

Cal Test Electronics
Cal Test Electronics CT2700 User manual

Cal Test Electronics
Cal Test Electronics Elditest CT2982B User manual

Cal Test Electronics
Cal Test Electronics CT2696C User manual



















