Beko BS207C User manual

Local air
conditioner
User Manual
BS207C
EN FR NL DE
07M-8500143200-5220-02

2 / 160 EN Local air conditioner / User Manuel
CONTENTS
ENGLISH 4-39
FRANÇAIS 41-78
NEDERLANDS 80-118
DEUTSCH 120-158

Please read this user manual rst!
Dear Customer,
Thank you for preferring a Beko product. We hope that you get the best results
from your product which has been manufactured with high quality and state-of-
the-art technology. Therefore, please read this entire user manual and all other
accompanying documents carefully before using the product and keep it as a
reference for future use. If you handover the product to someone else, give the user
manual as well. Follow all warnings and information in the user manual.
Meanings of the symbols
Following symbols are used in the various section of this manual:
This product has been produced in environmentally friendly, modern facilities
Complies with the WEEE Regulation. Does not contain PCB.
C
Important information or
useful hints about usage.
A
Warning for hazardous
situations with regard to life
and property.
Warning to actions that must
never perform.
B
Warning for electric shock.
Warning for hot surfaces.
Do not cover it.
This symbol shows that the
operation manual should be
read carefully.
This symbol shows that a
service personnel should be
handling this equipment with
reference to the installation
manual.
This symbol
shows that this
appliance used
a flammable
refrigerant. If
the refrigerant
is leaked and
exposed to an
external ignition
source, there is
a risk of fire.

4 / 160 EN Local air conditioner / User Manuel
The refrigerant used in mobile air conditioners is the environmentally friendly hydrocarbon R290.
This refrigerant is odorless, and compared to the alternative refrigerant, the R290 is an ozone-free
refrigerant, and its effect is very low.
Please read the instructions before use and repair.
The drawings provided in this manual may not be the same as the physical objects. Please refer to the
physical objects.
V2012007
CONTENTS
1 Safety nstructons 5
2 Features and components 21
2.1 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.2 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3 Control settng 23
3.1 Control panel operation instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.2 Operation instructions of remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
4 Protecton functon 26
5 Installaton and adjustment 27
5.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6 Dranage nstructons 30
7 Mantenance 32
7.1 Clean the surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7.2 Clean the lter screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7.3 Clean the upper lter screen frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8 Unt Storage 33
9 Troubleshootng 34
10Addendum 36
11 Installaton nstructons 37
11.1 F-Gas instruction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
12 Specfcatons 38

Local air conditioner / User Manuel 5 / 160 EN
Warnng matters:
•
Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the manufacturer.
•
The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an operating
gas appliance or an operating electric heater.)
•
Do not pierce or burn.
•
Be aware that refrigerants may not contain an odour.
•
Appliance shall be installed, operated and stored in a room with a
floor area larger than 7 m2
•
The appliance must be kept free from obstruction to ensure proper
function and mitigate safety hazards.
•
Servicing shall be performed only as recommended by the
manufacturer.
•
The appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
•
Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an
industry-accredited assessment authority, which authorises their
competence to handle refrigerants safely in accordance with an
industry recognised assessment specification.
•
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of
other skilled personnel shall be carried out under the supervision of the
person competent in the use of flammable refrigerants.
1 Safety nstructons

6 / 160 EN Local air conditioner / User Manuel
1 Safety nstructons
•
All working procedure that affects safety means shall only be
carried by competent persons.
C
Note:
•
The air conditioning is only suitable for indoor use, and is
not suitable for other applications.
•
Follow local grid interconnection rules while installing the
air conditioning and ensure that it is properly grounded.
If you have any question on electrical installation, follow
the instructions of the manufacturer, and if necessary,
ask a professional electrician to install it.
•
Place the machine in a flat and dry place and keep a
distance of above 50cm between the machine and the
surrounding objects or walls.
•
After the air conditioning is installed, ensure that the
power plug is intact and firmly plugged into the power
outlet, and place the power cord orderly to prevent
someone from being tripped or pulling out the plug.
•
Do not put any object into the air inlet and outlet of the
air conditioning. Keep the air inlet and outlet free from
obstructions.
•
When drainage pipes are installed, ensure that the
drainage pipes are properly connected, and are not
distorted or bended.
•
While adjusting the upper and lower wind-guide strips
of the air outlet, pluck it with hands gently to avoid
damaging wind-guide strips.

Local air conditioner / User Manuel 7 / 160 EN
C
Note:
•
When moving the machine, make sure that it is in an
upright position.
•
The machine should stay away from gasoline, flammable
gas, stoves and other heat sources.
•
Don’t disassemble, overhaul and modify the machine
arbitrarily, otherwise it will cause a machine malfunction
or even bring harm to persons and properties. To avoid
danger, if a machine failure occurs, ask the manufacturer
or professionals to repair it.
•
Do not install and use the air conditioning in the
bathroom or other humid environments.
•
Do not pull the plug to turn off the machine.
•
Do not place cups or other objects on the body to
prevent water or other liquids from spilling into the air
conditioning.
•
Do not use insecticide sprays or other flammable
substances near the air conditioning.
•
Do not wipe or wash the air conditioning with chemical
solvents such as gasoline and alcohol. When you need
to clean the air conditioning, you must disconnect the
power supply, and clean it with a half-wet soft cloth. If
the machine is really dirty, scrub with a mild detergent.
1 Safety nstructons

8 / 160 EN Local air conditioner / User Manuel
C
Note:
•
This appliance can be used by children aged from
8 years and above if they have been given supervision or
instruction concerning use of the appliance in a safe way
and understand the hazards involved. Cleaning and user
maintenance shall not be made by children unless they
are aged from 8 years and above and supervised. Keep
the appliance and its cord out of reach of children aged
less than 8 years.
•
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
•
The appliance shall be installed in accordance with
national wiring regulations.
•
Do not operate your air conditioner in a wet room such as
a bathroom or laundry room.
•
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety.
•
Children should be supervised to ensure that they do not
play with the appliance.
1 Safety nstructons

Local air conditioner / User Manuel 9 / 160 EN
C
•
Warning Do not use manuals to accelerate the defrosting
process or to clean, other than those recommended by
the manufacturer. The appliance shall be stored in a
room without Continuously operation ignition sources
(for example: open flames, an operation gas appliance or
an operating electric heater.) Do not pierce or burn. Be
aware that refrigerants may not contain an odour.
•
The appliance shall state the insulation of a residual
current device (RCD) having rated residual operating
current not exceeding 30mA.
•
This appliance is intended to be used in household and
similar applications such as
-
Staff kitchen areas in shops, offices and other working
environments;
-
farm houses;
-
by clients in hotels, motels and other residential type
environments;
-
bed and breakfast type environments;
Transportaton, markng and storage for unts
•
Transport of equipment containing flammable refrigerants
Compliance with the transport regulations
•
Marking of equipment using signs
Compliance with local regulations
•
Disposal of equipment using flammable refrigerants
Compliance with national regulations
1 Safety nstructons

10 / 160 EN Local air conditioner / User Manuel
•
Storage of equipment/appliances
The storage of equipment should be in accordance with the
manufacturer’s instructions.
•
Storage of packed (unsold) equipment
Storage package protection should be constructed such that
mechanical damage to the equipment inside the package will not
cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be
stored together will be determined by local regulations.
1. Information on servicing
1) Checks to the area
Prior to beginning work on systems containing flammable refrigerants,
safetychecksarenecessarytoensurethattheriskofignitionisminimised.
For repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
2)Work procedure
Work shall be undertaken under a controlled procedure so as to
minimise the risk of a flammable gas or vapour being present while
the work is being performed.
3)General work area
All maintenance staff and others working in the local area shall be
instructed on the nature of work being carried out. Work in confined
spaces shall be avoided. The area around the workspace shall be
sectioned off. Ensure that the conditions within the area have been
made safe by control of flammable material.
1 Safety nstructons
Table of contents
Languages:
Other Beko Air Conditioner manuals

Beko
Beko BEVPCC 090 User manual

Beko
Beko BEPN 09C User manual

Beko
Beko BEHPI 090 User manual

Beko
Beko BEWPI 090 User manual

Beko
Beko 30925 User manual

Beko
Beko Room Air Conditioner User manual

Beko
Beko RSVH09VS-I User manual

Beko
Beko BNFI 090 User manual

Beko
Beko BIVPA 090 User manual

Beko
Beko BS 107 CN User manual
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual