Beko BEHPI 090 User manual

Split-type room
air conditioner
User Manual
EN
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning unit.
Make sure to save this manual for future
reference.
02M-8501003200-4920-01
BIVPI 090 BIVPI 091 BIVPI 120 BIVPI 121
BIVPI 180 BIVPI 181 BIVPI 240 BIVPI 241
BEVPI 090 BEVPI 091 BEVPI 120 BEVPI 121
BEVPI 180 BEVPI 181 BEVPI 240 BEVPI 241
BEHPI 090 BEHPI 091 BEHPI 120 BEHPI 121
BEHPI 180 BEHPI 181 BEHPI 240 BEHPI 241

Please read this user manual rst!
Dear Customer,
Thank you for preferring a Beko product. We hope that you get the best results from
your product which has been manufactured with high quality and state-of-the-art
technology. Therefore, please read this entire user manual and all other accompanying
documents carefully before using the product and keep it as a reference for future
use. If you handover the product to someone else, give the user manual as well.
Follow all warnings and information in the user manual.
Meanings of the symbols
Following symbols are used in the various section of this manual:
This product has been produced in environmentally friendly, modern facilities
Complies with the WEEE Regulation. Does not contain PCB.
C
Important information or useful
hints about usage.
A
Warning for hazardous
situations with regard to life
and property.
Warning to actions that must
never perform.
B
Warning for electric shock.
Warning for hot surfaces.
Do not cover it.
This symbol shows that the
operation manual should be
read carefully.
This symbol shows that a
service personnel should be
handling this equipment with
reference to the installation
manual.
This symbol
shows that this
appliance used
a flammable
refrigerant. If
the refrigerant
is leaked and
exposed to an
external ignition
source, there is a
risk of fire.

Split-type room air conditioner / User Manual 3 / 28 EN
1 Safety instructions 4
2 Unit specifications and features 7
2.1 Unit parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.2 Achieving optimal performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.3 Inverter split type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.4 Fixed-speed type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.5 Other features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3 Manual operation (without remote) 14
3.1 How to operate your unit without the remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4 Care and maintenance 15
4.1 Cleaning your indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.2 Cleaning your air filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.3 Air filter reminders (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4.3.1 Air filter cleaning reminder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4.3.2 Air filter replacement reminder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4.4 Maintenance – long periods of non-use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.5 Maintenance – pre-season inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5 Troubleshooting 20
5.1 Common issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.2 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6 European disposal guidelines 24
7 Installation instructions 25
7.1 F-Gas instruction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
8 Specification 26
CONTENTS

4 / 28 EN Split-type room air conditioner / User Manual
WARNING:
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of
other skilled personnel shall be carried out under the supervision
of the person competent in the use of flammable refrigerants.
For more details, please refer to the “Information on servicing" on
"INSTALLATION MANUAL " (This is only required for the unit adopts
R32/R290 Refrigerant)
Read safety precautions before installation
Incorrect installation due to ignoring instructions can
cause serious damage or injury.
The seriousness of potential damage or injuries is classified as
Warning.
Warning
•This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play
with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
Installation warnings
•Ask an authorized dealer to install this air conditioner. Inappropriate
installation may cause water leakage, electric shock, or fire.
•All repairs, maintenance and relocation of this unit must be
performed by an authorized service technician. Inappropriate
repairs can lead to serious injury or product failure.
1 Safety instructions

Split-type room air conditioner / User Manual 5 / 28 EN
Warnings for product use
•If an abnormal situation arises (like a burning smell), immediately
turn off the unit and pull the power plug. Call your dealer for
instructions to avoid electric shock, fire or injury.
•Do not insert fingers, rods or other objects into the air inlet or
outlet. This may cause injury, since the fan may be rotating at high
speeds.
•Do not use flammable sprays such as hair spray, lacquer or paint
near the unit. This may cause fire or combustion.
•Do not operate the air conditioner in places near or around
combustible gases. Emitted gas may collect around the unit and
cause explosion.
•Do not operate the air conditioner in a wet room (e.g., bathroom or
laundry room). This can cause electrical shock and cause the product
to deteriorate.
•Do not expose your body directly to cool air for a prolonged period
of time.
Electrical warnings
•Only use the specified power cord. If the power cord is damaged, it
must be replaced by the manufacturer or certified service agent.
•Keep power plug clean. Remove any dust or grime that accumulates
on or around the plug. Dirty plugs can cause fire or electric shock.
•Do not pull power cord to unplug unit. Hold the plug firmly and pull
it from the outlet. Pulling directly on the cord can damage it, which
can lead to fire or electric shock.
1 Safety instructions

6 / 28 EN Split-type room air conditioner / User Manual
1 Safety instructions
•Do not use an extension cord, manually extend the power cord, or
connect other appliances to the same outlet as the air conditioner.
Poor electrical connections, poor insulation, and insufficient voltage
can cause fire.
Cleaning and maintenance warnings
•Turn off the device and pull the plug before cleaning. Failure to do
so can cause electrical shock.
•Do not clean the air conditioner with excessive amounts of water.
•Do not clean the air conditioner with combustible cleaning agents.
Combustible cleaning agents can cause fire or deformation.
Warning
•If the air conditioner is used together with burners or other heating
devices, thoroughly ventilate the room to avoid oxygen deficiency.
•Turn off the air conditioner and unplug the unit if you are not going
to use it for a long time.
•Turn off and unplug the unit during storms.
•Make sure that water condensation can drain unhindered from the
unit.
•Do not operate the air conditioner with wet hands. This may cause
electric shock.
•Do not use device for any other purpose than its intended use.
•Do not climb onto or place objects on top of the outdoor unit.
•Do not allow the air conditioner to operate for long periods of time
with doors or windows open, or if the humidity is very high.

Split-type room air conditioner / User Manual 7 / 28 EN
2.1 Unit parts
1
2
3
4
5
6
7
1. Front Panel
2. Display window
3. Power Cable (Some Units)
4. Remote control Holder (Some Units)
5. Remote Control
6. Functional Filter (On Front of Main Filter - Some Units)
7. Louver
Display code meanings
“ ” for 3 seconds when:
• TIMER ON is set
• FRESH, SWING, TURBO, SILENCE or SOLAR PV ECO features are turned on
“” for 3 seconds when:
• TIMER OFF is sett
• FRESH, SWING, TURBO, SILENCE or SOLAR PV ECO features are turned off
“” when anti-cold air feature is turned on
“” when defrosting
“” when unit is self-cleaning
“” when freeze protection is turned on
2 Unit specifications and features

8 / 28 EN Split-type room air conditioner / User Manual
2 Unit specifications and features
" " when wireless Control feature is activated (some units)
"" When ECO function(optional) is activated, the ' ' illuminates gradually one by one as -- --
--set temperature-- ...... in one second interval.
In Fan mode, the unit will display the room temperature.
In other modes, the unit will display your temperature setting.
C
Note:
A guide on using the infrared remote is not included in this literature package.
2.2 Achieving optimal performance
Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following
temperature ranges. When your air conditioner is used outside of these ranges, certain safety
protection features will activate and cause the unit to perform less than optimally.
2.3 Inverter split type
COOL mode HEAT mode DRY mode
Room temperature 17°C - 32°C
(63°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor temperature
0°C - 50°C
(32°F - 122°F)
-15°C - 30°C
(5°F - 86°F)
0°C - 50°C
(32°F - 122°F)
-15°C - 50°C
(5°F - 122°F)
(For models with
low temp. cooling
systems.)
0°C - 60°C
(32°F - 140°F)
(For special tropical
models)
0°C - 60°C
(32°F - 140°F)
(For special tropical
models)
For outdoor units with auxiliary electric heater
When outside temperature is below 0°C (32°F ), we strongly recommend keeping the unit plugged in
at all time to ensure smooth ongoing performance.

Split-type room air conditioner / User Manual 9 / 28 EN
2.4 Fixed-speed type
COOL mode HEAT mode DRY mode
Room
temperature 17° - 32°C (63° - 90°F) 0° - 30°C
(32° - 86°F)
10° - 32°C (50° - 90°F)
Outdoor
temperature
18° - 43°C (64° - 109°F)
-7° - 24°C
(19° - 75°F)
11° - 43°C (52° - 109°F)
-7° - 43°C (19° - 109°F)
(For models with low-temp
cooling systems)
18° - 43°C (64° - 109°F)
18° - 54°C (64° - 129°F)
(For special tropical models)
18° - 54°C (64° - 129°F)
(For special tropical models)
To further optimize the performance of your unit, do the following:
• Keep doors and windows closed.
• Limit energy usage by using TIMER ON and TIMER OFF functions.
• Do not block air inlets or outlets.
• Regularly inspect and clean air filters.
For a detailed explanation of each function, refer to the Remote Control Manual.
2.5 Other features
• Auto-restart
If the unit loses power, it will automatically restart with the prior settings once power has been
restored.
• Anti-mildew (some units)
When turning off the unit from COOL, AUTO (COOL), or DRY modes, the air conditioner will continue
operate at very low power to dry up condensed water and prevent mildew growth.
• Wireless control (some units)
Wireless control allows you to control your air conditioner using your mobile phone and a Wireless
connection.
• Louver angle memory (some units)
When turning on your unit, the louver will automatically resume its former angle.
• Refrigerant leakage detection (some units)
The indoor unit will automatically display “EC” when it detects refrigerant leakage.
For a detailed explanation of your unit’s advanced functionality (such as TURBO mode and its self-
cleaning functions), refer to the Remote Control Manual.
2 Unit specifications and features

10 / 28 EN Split-type room air conditioner / User Manual
C
Note:
Illustrations in this manual are for explanatory purposes. The actual shape of your
indoor unit may be slightly different. The actual shape shall prevail.
•Setting angle of air flow
Setting vertical angle of air flow
While the unit is on, use the SWING/DIRECT button to set the direction (vertical angle) of airflow.
1. Press the SWING/DIRECT button once to activate the louver. Each time you press the button, it
will adjust the louver by 6°. Press the button until the direction you prefer is reached.
2. To make the louver swing up and down continuously, press and hold the SWING/DIRECT button
for 3 seconds. Press it again to stop the automatic function.
Setting horizontal angle of air flow
The horizontal angle of the airflow must be set manually. Grip the deflector rod (See Fig.B) and
manually adjust it to your preferred direction.
For some units, the horizontal angle of the airflow can be set by remote control. please refer to the
Remote Control Manual.
C
Note on louver angles:
When using COOL or DRY mode, do not set louver at too vertical an angle for long
periods of time. This can cause water to condense on the louver blade, which will drop
on your floor or furnishings. (See Fig.A)
When using COOL or HEAT mode, setting the louver at too vertical an angle can reduce
the performance of the unit due to restricted air flow.
Do not move louver by hand. This will cause the louver to become out of sync. If this
occurs, turn off the unit and unplug it for a few seconds, then restart the unit. This will
reset the louver.
2 Unit specifications and features
Other manuals for BEHPI 090
2
This manual suits for next models
23
Table of contents
Languages:
Other Beko Air Conditioner manuals

Beko
Beko BSEOG 090 User manual

Beko
Beko BEEPI 090 User manual

Beko
Beko BPVOW 090 User manual

Beko
Beko BGMPI 090 User manual

Beko
Beko BEVPI 120 User manual

Beko
Beko BEVPI 090 User manual

Beko
Beko RSVC09VT-I User manual

Beko
Beko BINA 091 User manual

Beko
Beko BRVPF 090 User manual

Beko
Beko BEVPI 090 User manual
Popular Air Conditioner manuals by other brands

Fujitsu