Aranet PRO 12 User manual

USERS GUIDE
Aranet PRO User’s Guide
Applicable for Aranet PRO 12, Aranet PRO 50, Aranet PRO 100

FCC Compliance statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment o and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the device.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from the one the receiver is connected to.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Aranet PRO does not contain serviceable parts. Warranty will not be applicable in the
event Aranet PRO has been opened.
The information presented in this guide is the property of SAF Tehnika, JSC. No part of this document may
be reproduced or transmitted without proper permission from SAF Tehnika, JSC.
The specications or information contained in this document are subject to change without notice due
to continuing introduction of design improvements. If there is any conict between this document and
compliance statements, the latter will supersede this document.
SAF Tehnika, JSC has no liability for typing errors in this document or damages of any kind that result
from the use of this document.
To get up to date information about accessories and their availability, please contact sales representative.
Copyright Notice
Copyright © 2017 SAF Tehnika, JSC. All rights reserved.

Industry Canada Regulatory Statement
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following
two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts
de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire
de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si
le brouillage est susceptible d’en compromettre le fonctionnement.

TABLE OF CONTENTS
Introduction 1
Aranet PRO base station overview 2
What’s in the box 2
Aranet PRO 3
Aranet PRO ports 4
Aranet PRO Datasheet 4
Conguration 6
Router conguration WiFi 6
How to: Initial setup of Aranet PRO via WiFi 6
How to: Initial setup of Aranet PRO via router 6
How to: Initial setup of Aranet PRO connected to a Windows PC via Ethernet cable 6
How to: Initial Login 7
Recommended network conguration 7
Sensor pairing in Aranet SensorHUB 8
How to: Pair sensors to Aranet PRO 8
Sensor grouping in Aranet SensorHUB 10
How to: Using groups 10
Aranet SensorHUB overview 12
Main navigation bar 12
Main menu 12
Graphs 14
Notications 15
SMS screen 17
E-mail screen 17
Region 18
Sensor 18
Radio menu 18

System 19
Time menu 20
Backup menu 21
Firmware menu 21
Network 22
WiFi menu 22
Ethernet menu 23
Users 24
Terms of use 25
Warranty 25
RMA (Return Merchandise Authorization) form 29
Intellectual Property Rights 29
Cleaning And Maintenence 29
Accessories 30
Disclaimer 30
Additional information 30

1
INTRODUCTION
Aranet oers environmental monitoring solutions for a variety of businesses. Aranet PRO is an industrial
grade environment monitoring solution.
Aranet PRO comes in three variations - Aranet PRO 12, Aranet PRO 50 and Aranet PRO 100.
• Aranet PRO 100 permits connecting up to 100 sensors,
• Aranet PRO 50 allows 50 sensors, and
• Aranet PRO 12 grants 12 sensor connectivity per base station.
The base station has exceptional sensitivity of -130dBm and allows placing the sensors within line - of -
sight range of at least 3km/1.9mi.
All Aranet PRO base stations include embedded local web-server Aranet SensorHUB. Easy to use
interface allows viewing, analysing and comparing data in real time, setting thresholds for alarms as well
as exporting reports. Responsive design of the software adapts to smartphone, tablet or laptop.
Visit www.aranet.com for more information.

2
ARANET PRO BASE STATION OVERVIEW
What’s in the box
(1) Aranet PRO base station + Aranet SensorHUB software
(2) Aranet PRO base station mount with 2 W1412 screws
(3) AC power adapter
1
2
3

3
Aranet PRO
(1) Sensor data indicator LED – ashes amber every time a
data packet is received from a sensor.
(2) WiFi connection indicator LED – amber light when Aranet
PRO is connected to WiFi or works in Access Point mode
(3) LAN conncetion indicator LED – amber light when Aranet
PRO is connected to LAN connection through an Ethernet
cable
(4) 12V power indicator LED – green light when Aranet
PRO is connected to 12V power either through a PoE
connection or with the included AC power adapter
(5) Battery power indicator LED – red light when Aranet PRO
is using built in back up battery power
(1) Base station mount conguration for positioning on vertical surface (e.g. wall).
(2) Base station mount conguration for positioning on vertical surface (e.g. wall).
(3) Base station mount conguration for placement on horizontal surface (e.g. table).
SENSOR DATA
WIFI
LAN
12V
POWER FROM BATTERY
OFF ON LAN RESET
1
2
3
4
5
2 31

4
Aranet PRO ports
(1) On-O switch – switch in the left position means Aranet PRO is turned o, switch in the right
position means Aranet PRO is turned on
(2) DC Power port - for using the included AC power adapter to power Aranet PRO
(3) Ethernet port – for LAN connectivity as well as PoE connectivity
(4) Network reset button, press and hold for 5 seconds or more to reset network settings and
password of “root” user account
(5) USB port – for connecting USB GSM modem to enable SMS notication functionality
Aranet PRO Datasheet
Aranet PRO
Maximum sensors amount 100 / 50 / 12
Alarm type E-mail
Optional alarm SMS notication through USB modem
Data storage 10+ years with 100 sensors
Receiver sensitivity -130 dBm
Channels Channel 1: 917.3 / 922.9
Channel 2: 917.5 / 923.1
Channel 3: 917.7 / 923.3
Channel 4: 917.9 / 923.5
User interface Aranet SensorHUB
Interface accessibility PC, tablet or smart phone connected via Ethernet cable or local WiFi
connection
Temperature scale Celsius, Fahrenheit, Kelvin
Data resolution Temperature: 0.1°
Humidity: 1%
Data protection Password protected user accounts, encryption for data
Communication Ethernet cable, local WiFi
Power options AC Power adapter (12V, 0.5A)
Optional power supply with PoE adapter
Built in battery (backup power up to 30min)
Operating temperature 0°C to 40°C / 32°F to 104°F
1
2
3
4
5

5
Aranet PRO
Operating humidity 0% to 95% non-condensing
Dimensions 107x170x26 mm/ 4.2x6.7x1.02 in w/o mounting bracket
Ports 1 DC power, 1 Ethernet, 1 USB A
Weight 190g / 6.7oz w/o mounting bracket
Construction ABS Plastic, steel mounting bracket
Protection class IP40
FCC marking Yes
Included AC power adapter (12V, 0.5A), mounting bracket,
Aranet SensorHUB software
Terms of use The Customer is obliged to guarantee the usage, maintenance and preservation of the
Equipment at their own expense in a way that excludes the Equipment’s theft, loss, destruction, harming
and/or damaging (including as a result of mechanical damages, moisture, liquid related damages, lightning
and/or other similar events). The base station may only be used indoors, it needs to be protected from
environmental impact (snow, rain, direct sunlight).
!NOTE! Aranet PRO is supplied with built in UPS providing up to 30 minutes of power supply in case of
power shortage. It is meant only as a back up and should be used only during an emergency. If the device
discharges the UPS on Power ON position it may suer permanent damage.
!WARNING! ARANET PRO BASE STATIONS CONTAIN AN LI-ION 14500 PROTECTED TYPE
RECHARGEABLE BATTERY AND A CR2032 TYPE BATTERY. RISK OF DAMAGE IF BATTERY
IS REPLACED BY AN INCORRECT TYPE. THE USER IS RESPONSIBLE FOR DISPOSAL OF
BATTERIES ACCORDING TO THE STATE LEGISLATION.
This manual suits for next models
2
Table of contents
Other Aranet Measuring Instrument manuals