AEMC 6610 User manual

PHASE ROTATION METER
(NON-CONTACT) 6610
ENGLISH User Manual

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
The recommended verification interval for this
instrument is 12 months and begins on the date
of receipt by the customer. For verification, please
use our calibration services. Refer to our repair
and calibration section at www.aemc.com.
Serial #: ______________________________
Catalog #: 2121.12
Model #: 6610
Please fill in the appropriate date as indicated:
Date Received: _________________________
Date Calibration Due: ____________________
Chauvin Arnoux®, Inc.
d.b.a AEMC®Instruments
www.aemc.com

Phase Rotation Meter Model 6610
1
Table of Contents
1. INTRODUCTION 2
1.1 International Electrical Symbols.............................................3
1.2 DenitionofMeasurementCategories ..................................3
1.3 ReceivingYourShipment.......................................................3
1.4 OrderingInformation..............................................................4
1.4.1 AccessoriesandReplacementParts.......................4
2. PRODUCT FEATURES 5
2.1 Description.............................................................................5
2.2 Features.................................................................................5
2.3 Applications ...........................................................................5
2.4 ControlFeatures ....................................................................6
3. OPERATION 7
3.1 MakingMeasurements ..........................................................7
3.2 LiveWireCheck.....................................................................9
4. MAINTENANCE 10
4.1 ReplacingtheBattery ..........................................................10
4.2 Cleaning...............................................................................10
5. SPECIFICATIONS 11
RepairandCalibration..................................................................12
TechnicalandSalesAssistance ...................................................12
Limited Warranty ..........................................................................13
WarrantyRepairs..........................................................................13

2
Phase Rotation Meter Model 6610
CHAPTER 1
INTRODUCTION
Precautions Before Use
These safety warnings are provided to ensure the safety of personnel
and proper operation of the instrument.
• To ensure safe operation and usage of this instrument, follow instruc-
tions in this manual. Failure to observe Warnings may result in
SEVERE injury or death.
• It is recommended for use in distribution level and fixed installations,
as well as lesser installations, and not for primary supply lines, over-
head lines and cable systems.
• Do not exceed the maximum overload limits per function (see speci-
fications) nor the limits marked on the instrument itself. Never apply
more than 600V CAT IV or 1000V CAT III between the test lead and
ground/earth.
• Inspect the meter and test leads before each use. Do not use any
damaged parts.
• Never ground yourself when taking measurements. Do not touch
exposed circuit elements.
• Do not operate the tester in an explosive atmosphere.
• Exercise extreme caution when measuring voltage >50V and current
>10mA.
• Never open the battery compartment while measuring.
• Do not operate in a manner not specified or the instrument’s protec-
tion may be impaired.

Phase Rotation Meter Model 6610
3
1.1 International Electrical Symbols
This symbol signifies that the instrument is protected by double or reinforced
insulation.
CAUTION - Risk of Danger! Indicates a WARNING and that the operator
must refer to the user manual for instructions before operating the
instrument in all cases where this symbol is marked.
Important instructions to read and understand completely.
Important information to acknowledge.
Risk of electric shock. The voltage at the parts marked with this symbol may be
dangerous.
AC Alternating current
Compliance with the Low Voltage & Electromagnetic Compatibility European
directives (73/23/CEE & 89/336/CEE)
In the European Union, this product is subject to a separate collection
system for recycling electrical and electronic components In accordance
with directive WEEE 2002/96/EC
1.2 Definition of Measurement Categories
CAT II: For measurements performed on circuits directly connected
to the electrical distribution system. Examples are
measurements on household appliances or portable tools.
CAT III: For measurements performed in the building installation at
the distribution level such as on hardwired equipment in
fixed installation and circuit breakers.
CAT IV: For measurements performed at the primary electrical
supply (<1000V) such as on primary overcurrent protection
devices, ripple control units, or meters.

4
Phase Rotation Meter Model 6610
1.3 Receiving Your Shipment
Upon receiving your shipment, make sure that the contents are consis-
tent with the packing list. Notify your distributor of any missing items. If
the equipment appears to be damaged, file a claim immediately with the
carrier and notify your distributor at once, giving a detailed description
of any damage. Save the damaged packing container to substantiate
your claim.
1.4 Ordering Information
Phase Rotation Meter Model 6610.................................... Cat. #2121.12
Includes meter with attached test leads (black, red and blue) with large
alligator clips, soft carrying case, one 9V battery and user manual.
1.4.1 Accessories and Replacement Parts
Case - Replacement soft carrying case ............................ Cat. #5000.41
Order Accessories and Replacement Parts Directly Online
Check our Storefront at www.aemc.com for availability

Phase Rotation Meter Model 6610
5
CHAPTER 2
PRODUCT FEATURES
2.1 Description
The Phase Rotation Meter Model 6610 is an essential tool for any instal-
lation, inspection and maintenance facility. The Model 6610 is designed
to identify phase rotation on 3-phase systems and identify live and
open/de-energized phases. The phase order is determined as soon as
the leads are connected. Presence of live wires and phase sequence
are informed by LED indication and a buzzer as soon as detection has
occurred. The Model 6610 is ideal for installing rotating machinery or
motors, and for checking generator output.
2.2 Features
• Non-contact (no metal contact points)
• Operating voltage: 75 to 1000VAC
• Frequency range: 45 to 65Hz
• Phase rotation LED indicators (ABC or BAC)
• Bright LED indication Live or Open Phase (A, B, C)
• Includes three attached color-coded test leads with alligator clips for
easy connection to the device under test
• Clipping the non-electrical contact alligator sensor clips onto the
insulation of the phase conductor promotes operator safety during
measurement
• Low battery indicator
• Back cover includes a magnet feature that can mount the instrument
onto an AC distribution panel for easy measurement
• EN61010-1; 1000V CAT III; 600V CAT IV

6
Phase Rotation Meter Model 6610
2.3 Applications
• Verify proper phase wiring
• Detect open or de-energized phases
• Determine correct wiring for proper rotation on motors, pumps, etc.
2.4 Control Features
A /L1 B/L2 C/L3
BLACK RED BLUE
ON/OFF
BRIGHTER
CAT IV 600V
CAT III 1000V
45-65 Hz
75-1000VAC
PHASE ROTATION METER
MODEL 6610
BAC ABC B AT.
OK
45
3
2
1
1. Live/Open LED phase indicators
2. ON/OFF power button
3. LED brightness button
4. Phase sequence LEDs
5. Battery LED (flashes if low)

Phase Rotation Meter Model 6610
7
CHAPTER 3
OPERATION
3.1 Making Measurements
Before proceeding with a measurement, read the safety
notes on page 2.
1. Press the power button to turn on the instrument.
All of the LEDs will flash during the first 2 seconds. Only the Green
Battery OK LED will stay on at the completion of the self test.
Do not use the instrument if any of the LEDs do not function
properly.
2. Position the clamp on each conductor to be measured so that the
point of the triangle mark “▼” on each jaw of the measurement clip
is centered on each measured conductor.

8
Phase Rotation Meter Model 6610
3. Connect three clips as shown:
BLUE
RED
BLACK
C/L3
B/L2
A/L1
Black L1, to Phase-A. Red L2, to Phase-B. Blue L3, to Phase-C.
4. Measure a live insulated conductor carrying 75VAC or more first to
confirm each live LED lights up.
5. The presence of live wires and phase sequence are confirmed by
LED indication and buzzer as soon as detection is completed.
6. A, B and C LEDs are always lit up when the instrument detects a live
phase.
7. ABC Green LED ON = correct phase sequence
BAC Red LED ON = incorrect phase sequence
8. The maximum cable diameter that the measurement clips can
connect to is 1.18 inches (30mm).
Table of contents
Other AEMC Measuring Instrument manuals