Southwire Triggers TSS-01 User manual

TESTING EQUIPMENT
4VR8
Operating Instructions
Southwire™Triggers®
Wireless Safety Switch System
TSS-01
Read and understand all of the instructions and
safety information in this manual before operating
or servicing this tool.
FAILURE TO OBSERVE THESE WARNINGS
CAN RESULT IN SEVERE INJURY OR DEATH.

System Operation..........................................................................11-12
Table of Contents
Description
............................................................................................2
Safety.................................................................................................3-4
Purpose of this Manual.........................................................................4
Identification
……………………………………………………...........
5-10
Pairing Instructions…………………………………………………........11
Battery Charging and System Storage...............................................14
Parts List............................................................................................ 18
Specifications…..................................................................................18
Warranty.........................................................................................19-21
1

2
Description
The Triggers
®
dual remote foot pedal system is designed for power
control and safety for all your cable pulling and feeding applications.
The person operating the puller and the person feeding the wire both
have control over the puller’s motor. All of this is accomplished by
simply pressing down or lifting off the Triggers foot pedal. Both foot
pedals must be engaged in order for the puller motor to operate. Any
time either foot pedal is released, the puller motor will stop. The
Triggers Master and Remote units may also be used as standalone foot
pedals if desired, requiring only one operator to run the cable puller or
feeder’s motor. Communication between units is wireless. Triggers
®
foot switches will continue communication up to 1500 feet between
walls and obstructions and up to 3.7 miles line of sight. The Triggers
units are equipped with a series of lights indicating the units are in
range or that one pedal is depressed and the other is not. This helps to
decrease the chance of miscommunication during a wire pull.

33
Safety is essential in the use and maintenance of Southwire Tools and
Equipment. This instruction manual and any markings on the tool
provide information for avoiding hazards and unsafe practices related
to the use of this tool. Observe all of the safety information provided.
Readand understand all instructions and safety
information in this manual before operating or servicing thistool.
•Only qualified persons should operate the Triggers.
•Wear eye protection and hardhat when using this tool.
•Do not use tool while tiredor under the influence of drugs, alcohol,
or medication.
•Alwaysfollow operating procedures.
•Avoid accidental starting. Make sure switch is off before plugging it in.
•Do not operate this tool with a puller while wearing loose fitting
clothing.
• Lift foot off Trigger when wrapping rope on capstan.
•When using this tool, always follow the safety procedures set forth in
this manual as well as all other safety procedures necessary and proper
when using tools of this type.
WARNING:
Personal Safety Hazards
WARNING:
• Use this toolfor manufacturer’s intended purpose only. Any use other
than described in this manual can result in injury or property damage.
•Only qualified personnel should use Southwire™Triggers®Wireless
Safety Switch System.
Tool Use Hazards
WARNING:
Safety

4
Safety cont.
•Do not expose power tools to rain or wet conditions. Water entering a
power tool can increase the risk of electric shock.
•Do not place Triggers in standing water.
•Plug into a (GFCI) ground fault interrupted circuit outlet only.
•Use a 10 gauge 20 Amp 120 Volt extension cord.
•Maintain proper care of power cords. Do not use the cord to carry the tool
or pull the plug from anoutlet. Replace damaged cords immediately.
Damaged cords can increase the risk of electric shock.
•Do not use this tool near live circuits. Shut off and lock out power when
working near existing circuits.
Electric Shock Hazards
WARNING:
•Do not open or disassemble battery pack.
•Do not expose to fire or open flame.
•Do not mix batteries of varying sizes or chemistries or types.
•Do not puncture, deform, incinerate, or heat or use in environments
above 85°C or 194°F.
FAILURE TO OBSERVE THESE WARNINGS CAN RESULT
IN SEVERE INJURY OR DEATH.
Battery Pack
WARNING:
Purpose Of This Manual
This instruction manual is intended to familiarize personnel with the
safe operation for the Southwire
™
Triggers
®
Wireless Safety Switch
System. Keep this manual available to all personnel. Replacement
manuals are available upon request at no charge at
www.southwiretools.com.

5
Master Unit Identification
1. Power Switch
2. Stand Alone Switch
3. Stand Alone On Indicator Light
4. Power Indicator Light
5. Vac Low Indicator Light
6. Linked Indicator Light
7. Master Unit Stand Alone
Indicator Light
8. Stop Indicator Light
9. Ready Indicator Light
10. Running Indicator Light
11. Antenna
12. Signal Strength Indicator
13. Amperage Draw Indicator
14. Pair Unit Switch
15. Foot Pedal
16. A/C Power Input 20A 120V
17. A/C Power Output 20A 120V

6
Master Unit Identification cont.
VISUAL COMMUNICATION
•POWER LIGHT (RED): Indicates unit is powered on
•VAC LOW (AMBER): Indicates A/C line voltage has dropped below
recommended optimal range
•LINKED LIGHT (BLUE): Indicates that unit is linked to the system
•REMOTE UNIT STAND ALONE LIGHT (BLUE): Indicates that the remote unit
is in stand alone mode
•STOP LIGHT (RED): Indicates that pull is at complete stop
•READY LIGHT (AMBER): Indicates that one pedal is depressed and there is no
forced stop condition present
•FLASHING READY: Only one button under foot pedal is depressed
•RUNNING LIGHT (GREEN): Indicates that both pedals are depressed and the
pull is in progress
•AMPERAGE DRAW INDICATOR: Shows approximate amperage draw for the
puller motor. USE LOW GEAR WHEN AMPERAGE DRAW INDICATOR REACHES
MAX IF PULLER IS NOT ALREADY IN LOW GEAR.

7
Remote Unit Identification
1. Power Switch
2. Stand Alone Switch
3. Stand Alone On Indicator Light
4. Power Indicator Light
5. Vac Low Indicator Light
6. Linked Indicator Light
7. Master Unit Stand Alone
Indicator Light
8. Stop Indicator Light
9. Ready Indicator Light
10. Running Indicator Light
11. Antenna
12. Signal Strength Indicator
13. Battery Meter
14. Pair Unit Switch
15. Foot Pedal
16. A/C Power Input 15A 120V
17. A/C Power Output 15A 120V

8
Remote Unit Identification cont.
VISUAL COMMUNICATION
•POWER LIGHT (RED): Indicates unit is powered on
•VAC LOW (AMBER): Indicates A/C line voltage has dropped below
recommended optimal range
•LINKED LIGHT (BLUE): Indicates that unit is linkedto the system
•MASTER UNIT STAND ALONE LIGHT (BLUE): Indicatesthat the master unit
is in stand alone mode
•STOP LIGHT (RED): Indicates that pull is at complete stop
•READY LIGHT (AMBER): Indicates that one pedal is depressed and there is no
forced stop condition present
•FLASHING READY: Only one button under foot pedal is depressed
•RUNNING LIGHT (GREEN): Indicates that both pedals are depressed and the
pull is in progress
•BATTERY METER: Shows approximate level of charge during use and charging
•RAPID FULL FLASHING BATTERY METER: Shows battery or charging fault
•SINGLE FLASHING BAR: Shows approximate battery level while charging

9
Handheld Unit Identification
1. Power Switch
2. Power Indicator Light
3. Charge IndicatorLight
4. Linked Indicator Light
5. Stand Alone IndicatorLight
6. Stop Indicator Light
7. Ready Indicator Light
8. Running IndicatorLight
9. Antenna
10. Signal Strength Indicator
11. Battery Meter
12. Pair Unit Switch
13. Stop Switch
Other manuals for Triggers TSS-01
1
Table of contents
Languages:
Other Southwire Tools manuals

Southwire
Southwire RR-SW45 User manual

Southwire
Southwire XTS-01 User manual

Southwire
Southwire MSP-01 Manual

Southwire
Southwire HB1A-9 Series User manual

Southwire
Southwire MAX PUNCH 360 Manual

Southwire
Southwire Shoreline Reels RW User manual

Southwire
Southwire MAX PUNCH 360 Manual

Southwire
Southwire MAX PUNCH XD Manual