-5-
LOCK
Take off the Jumper
POWER
SUPPLY
L1 L2 PL S1+ GND
Unlock parameter setting(set in monitor)
Door Lock Controlled with Dry Contact
Note:
4. Setup the Unlock Mode of Monitor for different
lock types.
00:10 DS-1
About
Local Address 00.00
Video Standard AUTO
System Verson 00.01.00
Display Driver 1.0
Font 1.0
UI 1.0
INSTALLER SETUP 123
_
? + OK: Help Menu
@ + OK: Address Setting Menu
1. An external power supply must be used according
to the lock power requirements.
2. The internal relay contact is restricted to AC or
DC 24V/1A.
3. The jumper must be removed before connecting.
•Power-on-to-unlock (Fail Secure) type:
Unlock Mode=0 (by default)
•Power-off-to-unlock (Fail Safe) type:
Unlock Mode=1
•When the About page shows, press UNLOCK button on front panel and hold for 2
seconds.
•On main menu page, touch [Logo] icon to enter About page.
•A QWERTY keypad is shown. Refer to the following:
Note:
1. The CDV96KP must be connected before setting.
2. A set parameter will be saved in CDV96KP automatically, it only needs to be set on one
monitor.