Take off the Jumper
POWER
SUPPLY
BUS PL S+S-
Connect one lock
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according
to the lock.
2. The inside relay contact is restricted to AC or DC
24V/1A.
3. The jumper must be taken off before connecting.
4. Set the Unlock Mode of Monitor for different
lock types.
•Power-on-to-unlock type: Unlock Mode=0 (by
default - monitor code 8010)
Note:
1.must connect CDV96KP correctly before setting.
2.the parameter will be saved in CDV96KP automatically,so you need only set on one monitor.
3.the above diagram is t for icon menu series monitors only, to text menu series monitors,please refer to
the corresponding user manual.
•Power-off-to-unlock type: Unlock Mode =1
- monitor code 8011
Unlock parameter setting(set in monitor)
1.Touch icon on
main menu page.
2.Touch UNLOCK
button and hold for 2s.
3.A digital keypad will be
shown.
About
Local Address 00.00
Video Standard AUTO
System Verson 00.01.00
Display Driver 1.0
Front 1.0
UI 1.0
INSTALLER SETUP 123