Beurer FT 65 User manual

DE Multifunktions-Thermometer
Gebrauchsanweisung ....................................2
EN Multi-function thermometer
Instructions for use ......................................18
FR Thermomètre multifonction
Mode d’emploi.............................................33
ES Termómetro multifunción
Manual de instrucciones..............................48
IT Termometro multifunzione
Istruzioni per l’uso........................................ 63
TR Fonksiyonlu termometre
Kullanım kılavuzu .........................................78
RU Многофункциональный термометр
Инструкция по применению......................93
PL Termometr wielofunkcyjny
Instrukcja obsługi.......................................109
FT 65

18
Dear customer,
Thank you for choosing one of our products. Our name stands for high-quality, thoroughly tested products for applications in
the areas of heat, gentle therapy, blood pressure/diagnosis, weight, massage and air.
With kind regards,
Your Beurer team
Included in delivery
•
Thermometer
•
2 x 1.5V AAA batteries (LR03)
•
These instructions for use
Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users
and observe the information they contain.
1. Signs and symbols.......................................................... 19
2. Notes............................................................................... 20
3. Unit description ............................................................... 23
4. Initial use ......................................................................... 24
5. Setting the device............................................................ 24
6. What you should know about using this thermometer.... 24
7. Measuring........................................................................ 25
8. Changing the batteries.................................................. 28
9. Storage and maintenance ............................................. 29
10. Disposal......................................................................... 30
11. Technical data ............................................................... 30
12. Trouble-shooting ........................................................... 31
13. Warranty/service........................................................... 32
Contents
ENGLISH

19
1. Signs and symbols
The following symbols appear in these instructions for use and on the device:
WARNING
Warning notice indicating a risk of injury or damage to health.
IMPORTANT
Safety note indicating possible damage to the unit/accessory.
Note
Note on important information.
Observe the instructions for use
Application part, type BF
Disposal in accordance with the Waste Electrical and Electronic Equipment EC Directive – WEEE
The CE labelling certifies that the product complies with the essential requirements of Directive 93/42/EEC
on medical products.
Storage/Transport
Permissible storage and transport temperature and humidity
Operating
Permissible operating temperature and humidity

20
Manufacturer
20
PAP
Dispose of packaging in an environmentally friendly manner
Protect from moisture
Certification symbol for products that are exported to the Russian Federation and members of the CIS
2. Notes
Safety notes
Warning:
•
To measure temperature, insert the sensor tip of the thermometer carefully into the ear.
•
Use of the thermometer on dierent persons can be inappropriate in the event of certain acute infectious dis-
eases because of the possible spread of germs despite cleaning and disinfection. If you have any doubts, please
consult your doctor.
Notes on handling batteries
•
If your skin or eyes come into contact with battery fluid, flush out the affected areas with water and seek medical assis-
tance.
• Choking hazard! Small children may swallow and choke on batteries. Store the batteries out of the reach of small chil-
dren.
•
Observe the plus (+) and minus (-) polarity signs.
•
If a battery has leaked, put on protective gloves and clean the battery compartment with a dry cloth.

21
•
Protect the batteries from excessive heat.
•
Risk of explosion! Never throw batteries into a fire.
•
Do not charge or short-circuit batteries.
•
If the device is not to be used for a long period, take the batteries out of the battery compartment.
•
Use identical or equivalent battery types only.
•
Always replace all batteries at the same time.
•
Do not use rechargeable batteries.
•
Do not disassemble, split or crush the batteries.
General notes
•
Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to
other users and observe the information they contain.
•
This thermometer is a sensitive electronic device. Handle it with care and do not subject it to any mechanical
impacts.
•
Do not expose the device to direct sunlight.
•
Check before each use that the lens is intact. If it is damaged, please contact your retailer or the service address.
•
The thermometer is NOT waterproof. For this reason, direct contact with water or other liquids should be avoided.
•
The FT65 thermometer is only designed for the measuring area on the human body stated in the instructions for
use.
•
The device is only intended for the purpose stated in these instructions for use.
•
After each use, clean the measuring tip with a soft cloth moistened with disinfectant.
•
The thermometer has been designed for practical use, but is not a substitute for a visit to the doctor.
•
Before each repair query, first check the batteries and replace them if necessary.
•
Repairs must only be carried out by authorised service centres, otherwise the guarantee is invalidated.

22
•
This device complies with the EU Directive 93/42/EEC concerning medical products, the Medizinproduktege-
setz (German Medical Devices Act), the ASTM (American Society for Testing and Materials) E 1965-98 and the
European Standard EN 12470-5: Clinical thermometers – Part 5: Requirements for infrared ear thermometers
(with maximum device) ISO 80601-2-56 and the European Standard EN60601-1-2 (in accordance with CISPR11,
IEC61000-4-2, IEC61000-4-3, IEC61000-4-8), and is subject to particular precautions with regard to electromag-
netic compatibility. Please note that portable and mobile HF communication systems may interfere with this unit.
For more details, please contact our Customer Services at the address indicated.
•
If you should have any questions about using our devices, please contact either your retailer or customer
services.
Notes on electromagnetic compatibility
•
The device is suitable for use in all environments listed in these instructions for use, including domestic
environments.
•
The use of the device may be limited in the presence of electromagnetic disturbances. This could result in issues
such as error messages or the failure of the display/device.
•
Avoid using this device directly next to other devices or stacked on top of other devices, as this could lead to
faulty operation. If, however, it is necessary to use the device in the manner stated, this device as well as the
other devices must be monitored to ensure they are working properly.
•
The use of accessories other than those specified or provided by the manufacturer of this device can lead to an
increase in electromagnetic emissions or a decrease in the device’s electromagnetic immunity; this can result in
faulty operation.
•
Failure to comply with the above can impair the performance of the device.

23
3. Unit description
Overview
132 4 5 6
7
1098
1 Forehead/cover cap
2 Forehead thermometer mode button
Stirn
Forehead
3 Ear thermometer mode/on button
Ohr
Ear /
4 LED (red) (high temperature alarm)
5 LED (green)
6 LCD
7 Sensor tip with lens (cover cap removed)
8 Memory button
9 Set button
10 Battery compartment lid
11 Date
12 Time
13 Measurement mode (“Ear”, “Forehead”, “Object”)
14 Battery warning symbol
15 Measurement display
16 “Memory” symbol and storage space number
17 “Measurement in progress” symbol
18 Unit of measurement (°C or °F)
863
5-15
8
7:20
11
12
13
18
17
161514

24
4. Initial use
The batteries are already inserted in all new devices. Before first use, remove the protruding plastic insulating strip from the
battery compartment. The thermometer will then switch on automatically.
Further information and FAQs available at: http://www.beurer.com
5. Setting the device
Set the unit for the temperature display as well as the date and the time.
888
8
88:88
Press the button for 1 second to switch the thermometer on. The device performs a brief
self test: all elements of the display are shown for approx. 1 second. Following a successful
self test, the device emits two short beeps. In Standby mode, the date and time are shown
and “ ” is displayed.
When the thermometer is used for the first time and each time the batteries are changed, the date and time are displayed (after
the self test) in the basic setting ( ). Now set the unit in which the temperature will be displayed, the date and the
time. To set the device, proceed in stages: Unit – year – month – day – hours – minutes.
•
Press the button for approx. three seconds in order to reach Set mode.
The setting to be changed will flash each time.
•
Press the button again to save the setting or
•
press the button to change the setting.
•
Then press the button to save the setting.
After this process, the thermometer shows the word in the display and switches o automatically.
6. What you should know about using this thermometer
There are dierent thermometers for taking temperature measurements in dierent parts of the body:
•
Ear/forehead thermometer (this thermometer, for measuring in the ear or on the forehead area)
•
Rod thermometer (for rectal [in the back passage], axillary [under the arm] or oral measurement [in the mouth])

25
Taking the temperature gives a measurement that provides information about a person’s current body temperature.
If you are uncertain about interpreting the results or if the value is abnormal, please consult your doctor. This also
applies in the case of slight temperature changes if there are other symptoms of illness such as agitation, severe
sweating, flushed skin, fast pulse rate, tendency to collapse, etc.
Temperatures measured with dierent thermometers cannot be compared with one another. You should therefore tell
your doctor (or bear in mind if you are diagnosing yourself) what thermometer you used to take your temperature and
in what part of the body.
The temperature of a healthy person is influenced by various factors: individual metabolic rate, which depends on the
person, age (body temperature of infants and small children is higher and decreases as they age). Greater tem-
perature fluctuations occur faster and more often in children, e.g. due to growth spurts), their clothing, the ambient
temperature, the time of day (body temperature is lower in the morning and increases throughout the day towards
evening), the preceding physical and, to a lesser extent, mental activity.
The temperature varies depending on the part of the body where the measurement is taken. The dierence can be
between 0.4°F (0.2°C) and 1.8°F (1°C) for a healthy person. The normal temperature ranges are as follows:
•
on the forehead: 96.4°F – 99.7°F (35.8°C – 37.6°C), with a forehead thermometer,
•
in the ear: 96.8°F – 100°F (36.0°C – 37.8°C), with an ear thermometer,
•
in the back passage: 97.3°F – 100°F (36.3°C – 37.8°C), with a conventional thermometer,
•
in the mouth: 96.8°F – 99.3°F (36.0°C – 37.4°C), with a conventional thermometer.
In order to track temperature change, always take the measurements in the same part of the body.
7. Measuring
Before each use, please check that the lens is intact. If it is damaged, please contact your retailer or the service address.
Bear in mind that the thermometer needs to have been in the room in which the measurement is taken for at least 30minutes
before use.

26
Measuring body temperature in the ear
•
Some people produce dierent readings in their left and right ear. In order to record temperature changes, always
measure a person’s temperature in the same ear.
•
The ear thermometer may be used by children only under adult supervision. Measurement is usually possible over
the age of 6 months. In infants under 6 months, the ear canal is still very narrow so the temperature of the eardrum
often cannot be recorded and the result displayed is often too low.
•
The measurement must not be taken in an ear aected by inflammatory diseases (e.g. discharging pus or secre-
tion), after possible ear injuries (e.g. eardrum damage) or in the healing period after operative procedures. In all of
these cases, please consult your doctor.
•
Use of the thermometer on dierent persons can be inappropriate in the event of certain acute infectious dis-
eases because of the possible spread of germs despite cleaning and disinfection. If you have any doubts, please
consult your doctor.
•
This thermometer may only be used without a disposable protective cover.
•
If you have been lying on one ear for some time, the temperature is slightly raised. Wait a little while or measure in
the other ear.
•
As ear wax can aect the measurement, you should clean the ear before measuring if necessary.
•
Press the button for 1 second to switch the thermometer on. Follow-
ing a successful self test, the device emits two short beeps.
•
Remove the cap by gently pushing it up (1) and then pulling it o for-
wards (2).
12
Other manuals for FT 65
4
Table of contents
Other Beurer Thermometer manuals

Beurer
Beurer FT 90 User manual

Beurer
Beurer FT 78 User manual

Beurer
Beurer FT 09/1 User manual

Beurer
Beurer FT 90 User manual

Beurer
Beurer OT 30 User manual

Beurer
Beurer FT 90 User manual

Beurer
Beurer FT 55 User manual

Beurer
Beurer FT 65 User manual

Beurer
Beurer FT 70 User manual

Beurer
Beurer FT 70 User manual

Beurer
Beurer FT 55 User manual

Beurer
Beurer FT 58 User manual