Security system is disarmed
(if the indication is activated)
Blinks twice with the LED ring and emits two short sound signals
Siren in the armed mode (if
the indication is activated)
LED in the corner lights up with a pause of 2 seconds
LED in the corner lights up and goes out when the system is
armed/disarmed, the alarm is actuated in case of dismounting or
unauthorized opening
Performance testing
The Ajax security system allows conducting tests for checking the functionality of connected
devices.
The tests do not start straight away but within a period of 36 seconds when using the standard
settings. The test time start depends on the settings of the siren scanning period (the
paragraph on “Jeweller” settings in Hub settings).
Volume Test
Signal Strength Test
Attenuation Test
Installing the Siren
Location of the StreetSiren determines its remoteness from the hub and presence of any
obstacles between the devices, hindering the radio signal and sound transmission: walls,
inserted floors, large-size objects located within the room.
Check the signal level at the installation location
The communication range is up to 1,500 meters if there are no obstacles, please consider it
when choosing an installation place for StreetSiren.
If the signal level is one division, we cannot guarantee stable operation of the security system.
Take possible measures to improve the quality of the signal! As a minimum, move the device -
even 20 cm shift can significantly improve the quality of reception.
If, after moving, the device still has a low or unstable signal strength, use a radio signal range
extender ReX.
The siren body has the dust/moisture protection class IP54 - the device may be placed
outdoors. Recommended installation height - 2.5 meters and more. This will complicate the
access to the device for intruders in case of entering.
In installing and operating the StreetSiren, follow the general electrical safety regulations for
using electrical appliances, as well as the requirements of regulatory legal acts on electrical
safety.
It is strictly prohibited to disassemble the device under voltage! Do not use the device
with a damaged power cord.
Siren Installation