WIKA TF-LCD User manual

DE
EN
Operating instructions
Betriebsanleitung
Mode d‘emploi
Manual de instrucciones
ES
FR
Longlife digital thermometer, model TF-LCD
Longlife digital thermometer
Model TF-LCD
Longlife-Digital-Thermometer
Typ TF-LCD
Thermomètre digital à longue durée de vie
Type TF-LCD
Longlife termómetro digital
Modelo TF-LCD

2
14494176.02 01/2022 EN/DE/FR/ES
WIKA operating instructions model TF-LCD
DE
EN
ES
FR
Operating instructions model TF-LCD Page 3 - 18
Betriebsanleitung Typ TF-LCD Seite 19 - 34
Mode d‘emploi type TF-LCD Page 35 - 50
Manual de instrucciones modelo TF-LCD Página 51 - 65
© 12/2021 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!

EN
WIKA operating instructions model TF-LCD
14494176.02 01/2022 EN/DE/FR/ES
3
Contents
Contents
1. General information 4
2. Design and function 5
3. Safety 7
4. Transport, packaging and storage 10
5. Commissioning, operation 11
6. Faults 12
7. Maintenance and cleaning 13
8. Dismounting, return and disposal 14
9. Specications 16

EN
14494176.02 01/2022 EN/DE/FR/ES
4WIKA operating instructions model TF-LCD
1. General information
■
The longlife digital thermometer described in the operating instructions
has been manufactured using state-of-the-art technology. All
components are subject to stringent quality and environmental criteria
during production. Our management systems are certied to ISO 9001
and ISO 14001.
■
These operating instructions contain important information on handling
the instrument. Working safely requires that all safety instructions and
work instructions are observed.
■
Observe the relevant local accident prevention regulations and general
safety regulations for the instrument's range of use.
■
The operating instructions are part of the product and must be kept in
the immediate vicinity of the instrument and readily accessible to skilled
personnel at any time. Pass the operating instructions on to the next
operator or owner of the instrument.
■
Skilled personnel must have carefully read and understood the
operating instructions prior to beginning any work.
■
The general terms and conditions contained in the sales documentation
shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: TE 85.01
- Application consultant: Tel.: +49 9372 132-0
1. General information

EN
WIKA operating instructions model TF-LCD
14494176.02 01/2022 EN/DE/FR/ES
5
2. Design and function
2.1 Overview
LC display
Solar panel
Insertion thermometer
2.2 Description
The model TF-LCD longlife digital thermometer consists of a insertion
thermometer with up to 3 metres of measuring line and a permanently
connected digital LC display.
The LC display is powered by a built-in (not exchangeable) battery or a
built-in solar panel and does not require any separate supply voltage.
All electrical components are protected against dust.
2. Design and function

EN
14494176.02 01/2022 EN/DE/FR/ES
6WIKA operating instructions model TF-LCD
2.3 Dimensions in mm [in]
2.4 Scope of delivery
Cross-check scope of delivery with delivery note.
29,5
[1,161]
62,2
[2,449]
14,4
[0,567]
24,3
[0,957]
6,3
[0,248]
R5
[0,197]
57,7
[2,272]
7,5
[0,295]
25,3
[0,996]
5
[0,197]
<=29
[1,142]
8
[0,315]
2,5
[0,098]
25
[0,984]
4
[0,157]
5,5
[0,217]
Ø
°C
ML
TF-LCD Solar
14204741.02
Solar
14204741.02
62,2
[2,449]
R5
[0,197]
57,7
[2,272]
2,5
[0,098]
14
[0,551]
25
[0,984]
5,5
[0,217]
<=35
[1,378]
14
[0,551]
2,5
[0,098]
25,3
[0,996]
5
[0,197]
14,5
[0,571]
7,5
[0,295]
24,3
[0,957]
6,3
[0,248]
TF-LCD Bat
14204741.02
°C
ML
Battery
14204741.02
2. Design and function

EN
WIKA operating instructions model TF-LCD
14494176.02 01/2022 EN/DE/FR/ES
7
3. Safety
3.1 Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in
serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in
light injuries or damage to property or the environment, if not
avoided.
Information
... points out useful tips, recommendations and information for
ecient and trouble-free operation.
3.2 Intended use
The model TF-LCD longlife digital thermometer is used for temperature
measurement in the widest variety of industrial applications in cooling
and refrigeration technology as well as in heating, air-conditioning and
ventilation technology. It is designed for installation in a case, control panel,
console or similar. This instrument is not approved for use in hazardous
areas!
The instrument has been designed and built solely for the intended use
described here, and may only be used accordingly.
The technical specications contained in these operating instructions must
be observed. Improper handling or operation of the instrument outside of its
technical specications requires the instrument to be taken out of service
immediately and inspected by an authorised WIKA service engineer.
The manufacturer shall not be liable for claims of any type based on
operation contrary to the intended use.
3. Safety

EN
14494176.02 01/2022 EN/DE/FR/ES
8WIKA operating instructions model TF-LCD
3.3 Improper use
WARNING!
Injuries through improper use
Improper use of the instrument can lead to hazardous situations
and injuries.
▶
Refrain from unauthorised modifications to the instrument.
▶
Do not use the instrument within hazardous areas.
▶
Do not use the instrument with abrasive or viscous media.
Any use beyond or dierent to the intended use is considered as improper
use.
3.4 Responsibility of the operator
The instrument is used in the industrial sector. The operator is therefore
responsible for legal obligations regarding safety at work.
The safety instructions within these operating instructions, as well as the
safety, accident prevention and environmental protection regulations for the
application area of the instrument must be maintained.
Observe the information on the product label.
To ensure safe working on the instrument, the operating company must
ensure
■
that the operating personnel are regularly instructed in all topics
regarding work safety, rst aid and environmental protection and know
the operating instructions and, in particular, the safety instructions
contained therein.
■
that the instrument is suitable for the particular application in
accordance with its intended use.
■
that personal protective equipment is available.
3. Safety

EN
WIKA operating instructions model TF-LCD
14494176.02 01/2022 EN/DE/FR/ES
9
3.5 Personnelqualication
WARNING!
Riskofinjuryshouldqualicationbeinsucient
Improper handling can result in considerable injury and damage
to property.
▶
The activities described in these operating instructions
may only be carried out by skilled personnel who have the
qualifications described below.
Skilled personnel
Skilled personnel, authorised by the operator, are understood to be
personnel who, based on their technical training, knowledge of measurement
and control technology and on their experience and knowledge of country-
specic regulations, current standards and directives, are capable of carrying
out the work described and independently recognising potential hazards.
3.6 Labelling, safety marks
Product label (example)
Model
Production order number
Scale range
Before mounting and commissioning the instrument, ensure you
read the operating instructions!
Do not dispose of with household waste. Ensure a proper
disposal in accordance with national regulations.
D-63911 Klingenberg
3. Safety

EN
14494176.02 01/2022 EN/DE/FR/ES
10 WIKA operating instructions model TF-LCD
4. Transport, packaging and storage
4.1 Transport
Check the instrument for any damage that may have been caused by
transport. Obvious damage must be reported immediately.
CAUTION!
Damage through improper transport
With improper transport, a high level of damage to property can
occur.
▶
When unloading packed goods upon delivery as well as
during internal transport, proceed carefully and observe the
symbols on the packaging.
▶
With internal transport, observe the instructions in chapter
4.2 “Packaging and storage”.
If the instrument is transported from a cold into a warm environment, the
formation of condensation may result in instrument malfunction. Before
putting it back into operation, wait for the instrument temperature and the
room temperature to equalise.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport
(e.g. change in installation site, sending for repair).
Permissible conditions at the place of storage:
■
Storage temperature: -20 … +50 °C [-4 ... +122 °F]
■
Humidity: 35 ... 85 % relative humidity (no condensation)
Avoid exposure to the following factors:
■
Direct sunlight or proximity to hot objects
■
Mechanical vibration, mechanical shock (putting it down hard)
■
Soot, vapour, dust and corrosive gases
■
Hazardous environments, ammable atmospheres
Store the instrument in its original packaging in a location that fulls the
conditions listed above.
4. Transport, packaging and storage
Table of contents
Languages:
Other WIKA Thermometer manuals