Page | 6
Installation Instructions for the Semak Hand Dryer
Before installation consider the following points:
1. Do not install in places of excessive condensation, humidity or water build up.
2. Direct installation to mains power must be carried out by a registered electrician.
3. Hand Dryer must be installed and used indoors only.
4. Use only 220-240V / 50Hz AC power source.
Installation Location:
1. Unit must be installed above 150mm height from the floor to prevent water from
entering the unit during cleaning.
2. The left side of the unit must be at least 150mm from the wall (due to the power
switch being located on the left hand side of the unit).
3. Ensure no mirrors or walls are closer than 100mm to the right of the unit and no
fixtures closer than 400mm as water may splatter when drying hands.
4. Avoid locations where people or doors might bump into the unit.
5. Ensure the wall surface is completely flat and level before mounting.
6. Ensure the unit is mounted well away from any heat sources, corrosive or
flammable gases to avoid product failure or fire.
7. Suggested Installation Height: 950mm –1100mm from the floor to top of unit
8. Electrical Installation Options: Use the supplied Australian lead and plug or use a
registered electrician to wire connection direct to mains power.
Installation Instructions:
1. Remove the product from its packaging (do not discard).
2. Locate the water collection / drip tray and remove from unit.
3. Locate the air filter compartment and
remove filter from unit.
4. Fix the mounting plate onto the wall using
the supplied expanding screws & plugs.
5. Hang the hand dryer onto the metal
mounting plate ensuring that both upper
and lower hooks are firmly in place.
6. Replace security screw, air filter & water
collection/drip tray to finish installation.