I. Features
1. GSM 900/1800/1900 bands, can be used all o er the world.
2. 3 zones for wired detectors and 16 zones for wireless detectors.
3. Set arm, disarm, emergency alarm by remote controller.
4. Set arm, disarm, monitor, output by calling the host.
5. Set arm, disarm, monitor, output by sending SMS.
6. Monitor en ironment on the spot.
7. Voice and message alert.
8. 5-group phone + room number; 1 group alarm monitor center
phone.
9. 2-group phone to report alarm and non-alarm status.
10. Can program 7-group alarm messages.
11. Easy to set ON or OFF for e ery wired or wireless detector.
12. 1 relay output to trigger camera when alarm.
13. 2 output for home appliances connection (lamp, cooker, air
condition).
14. SMS alert for external power failure or reco ery.
15. Built-in battery ensures normal work e en power failure.

II. Installation
1. Host
a.
Insert SIM card in alarm system
Press the yellow point on the unit with a pencil tip or other tools, SIM
card tray will come out. Put the SIM card into the tray and make sure
the Metal contacts of the card to be downwards, and then push the
tray back.
Before inserting SIM card in the alarm unit, using a regular mobile
phone do the following steps:
---Set PIN code request to off
---Delete all stored numbers
b. onnect the antenna
Screw the antenna to the unit carefully; do not o er-tighten the nut
or lea e it too loose!
c. onnect the power supply
Plug the alarm system into power and turn on the power switch. The
signal status LED on the unit will turn red and last for 20 seconds. This
shows it’s waiting for wireless detectors to be coded into the unit. Then
the status LED will turn orange with flash, indicating the unit is checking
the SIM card and searching for GSM network. After checking, if the LED
changes to green with slow flash, it shows phone numbers ha e been
sa ed in the unit, and the unit is now in “Arm” status. If the LED keeps in
green, it means phone numbers ha e not been sa ed in the unit, and
the unit is in “Disarm” status, you can call in or send SMS to program
the phone numbers.

LED status explanation
LED LED Status System working status
POWER
Off
Hasn’t turned on the switch; hasn’t
connected the power; no power in built-in
battery
Red power supply is normal
ST
AT
US
Power
on
Red Ready to code wireless sensors
Orange (flash slowly) Check SIM card and search GSM network
Green (flash slowly) SIM card and GSM signal are normal; ha e
stored numbers in SIM card; in arm status
Green ha e not stored numbers in SIM card; in
disarm status
Normal
working
Red (flash slowly) In alarm status
Red (flash quickly) Remote controlled by SMS commands or
phone
Green Disarm
Green (flash slowly) Out Arm
Green (flash quickly) Home Arm
MONITOR
On Can monitor the scene when alarming, but
the siren will not ring
Off Can not monitor the scene when alarming,
but the siren will ring
ALARM
On The siren will ring when alarming
Off The siren will not ring when alarming
d. onfiguration of the alarm unit:
There are 10 connect ports at the top side of the unit:
(GND; SIREN; RELAY1; RELAY2; O3 (SPEAKER); O2; O1; I3; I2; I1):
GND: power ground.
SIREN:
Connect the black wire to GND port and the red wire to siren port.

I1, I2, I3:
onnect wired sensors
Three inputs are a ailable to connect wired sensors. Inputs are
independent and not coded as different zones. When these sensors are
triggered, the unit will sent SMS message:
Wire Activate (1~3).
Sensors can be NO (normally Open) or NC (normally Close) type.
More than 1 sensor can be connected to one input: connect their alarm
contacts in series. The number of the sensors is not limited as long as
the total resistance is under 220 ohms.
O1, O2:
These 2 ports for output, you can call in or send SMS to set them. If
output of these goes high, the light of OUT 1 or OUT 2 will light on the
panel. (non-specialist should use it with caution!!)

O3 (SPEAKER):
This port is for oice output, it can be connected to the speaker. The
other port of the speaker is to connect to ground. You can control it by
call in or send the SMS.
RELAY1, RELAY2:
These two ports will close 3 minutes when alarm happens. You can use
these two ports to start the power supply of the camera when alarm
happens, also you can disable this function by setting command 16#1#,
you can also make this relay close or open anytime by sending SMS or
dialing (94#1# or 94#0#).
Wiring Explanation: For home-appliance control (for special order)
The controller box has four wires:
i). Two yellow AC 220 wires to be connected with Home appliance.
ii). GND, +12V DC wires to be connected with a 12V DC (Power
supply)
NOTE:
Try to install the main panel in the center of defense zone and pull
out the antenna to get longer wireless recei ing distance.
Installation position should be far away from huge metal objects
and wireless interference.

2. Door sensor
Door sensors are used for detecting the status of open and close of
windows and doors. It will detect it and send the signal to main panel.
1. Tear apart the double-side adhesi e tape on the magnet and the
transmitter. Then adhere them to the appropriate position.
2. Magnet should be near to the side of transmitter with indicator.
The two should align with each other and the distance should not
exceed 10mm.
3. Please plug out the antenna
for better signal.
4. If the low-power indicator is on,
please change the battery.
3. Wireless PIR detector
PIR detectors are used to detect the mo ement within a certain range.
Fix the adjustment bracket on the wall with the pro ided screws
and attach the detector to the bracket. It is recommended to
mount it at a height of 2-2.2m abo e the floor.
Effect of the PIR detection is best when the detection direction is
in 90°angle with the walking direction of the intruder. Choose the
most suitable installation place and angle according to actual
situation and taking the following installation diagram as reference
to ensure the detection effect is best.
Please do not fix it under direct sunlight or other strong lights and
also keep it away from places with frequent strong air stream.
If the low-power indicator is on, please change the battery.

III. Set alarm phone numbers
You can send message to the unit to set 5 alarm phone numbers and 7
alarm SMS.
The command format: password #operation code # content #
1. Sa e the alarm phone numbers.
123456#5X# alarm phone numbers #. (X = 1 to 5)
Sa e 5 group alarm phone numbers into the base.
For example: 123456#51# 13905950001#
Sa e the 1st alarm phone number 13905950001 into the base.
2. There are 7 default SMS contents in the base, but you can change it.
When the wireless detector in zone 01 to 05 is triggered, the default
SMS content will be: Wireless Acti ated (X); X can be 01 to 05.
For example:
if detector in zone 01 is triggered the SMS will be:
Wireless Acti ated (01)
When the wireless detector in zone 06 to 16 is triggered, the default
SMS content will be:
Wireless Acti ated (X); (X=06-16)
When the wire detector is triggered, the SMS message will be: Wire
Acti ated (X);(X=1-3), for port 1 to 3 alarm

3. You can send SMS commands to rewrite the abo e 7 kinds of SMS
contents, e ery SMS cannot excess 24 English characters.
123456#8X# SMS content #. (X = 1 to 5)
For example:
Rewrite the 1
st
SMS content into “Middle door open”:
123456#81#Middle door open#
Rewrite the 6
th
to 16
th
SMS content into “Middle window open”:
123456#86# Middle window open#.
Rewrite the wire detectors SMS content into “Back window open”
123456#87# Back window open#.
IV. Test the host alarm
When you start the base, if the base is in Disarm status, the signal LED
keep still green, you can use controller to change the base into Arm
status, or you can send SMS (123456#1#1#) to the base to change the
base into Arm status, the signal LED will change to flashing green.
1. Under Arm status, with green LED on, any port of input (I1, I2, I3)
short circuit or disconnected, or any wireless detectors has been
acti ated, or you press the emergency key on the controller, the
alarm system will send alarm information by SMS, and dialing out
stored telephone numbers.
2. It will send SMS before dial alarm phone numbers. If the SMS
function has been closed or limited, it will only dial out the preset
telephone numbers. You can make them disarm with remote
controller.
3. When there is alarm, it will dial out phone numbers, you can answer

the phone (not need input password) to operate it, press 3# 1# to
start the siren and press 3# 0# to stop it; press 4# 1# to listen-in and
press 4# 0# to stop it; press 93# 1# to talk with the spot and press
93# 0# to stop it.
4. When there is alarm, it will dial out phone numbers, you can
answer the phone(not need input password ),if you do not want the
unit to dial next phone numbers, just press 1# 1# or 1#2# to re-turn
the unit into Arm status.
5. When there is alarm, you can use the controller to change the
base into disarm status when you are in nearby can control the
situation.
6. When the external power is cut off, the system will send SMS
“Power changer off” to inform. When the external power
reco ered, the system will send SMS “Power changer on” to
inform.
V. ontrol the host
1. Send message to the host phone number (SIM Card number)
Send message to the unit: password 123456#, add the following
commands to control the unit;
2. Call the host phone number (SIM Card number)
Call in the unit and enter password 123456#, then input the following
command to set the base:
Other manuals for GSM-01
1
Table of contents
Other Pisector Security System manuals

Pisector
Pisector GS08 User manual

Pisector
Pisector GS08 User manual

Pisector
Pisector GS08 User manual

Pisector
Pisector GSM-01 User manual

Pisector
Pisector PS03 User manual

Pisector
Pisector PS03 User manual

Pisector
Pisector P09 series User manual

Pisector
Pisector Motion sensor User manual

Pisector
Pisector GSM-03 User manual

Pisector
Pisector GSM-06 User manual
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual