netvox ZigBee ZB11B User manual

ZigBeeTM- Motion On-Off Switch
User Manual
Motion On-Off Switch
Model: ZB11B
20140109
FW V2.0
HW V1.0

1
Table of Contents
1. Introduction.............................................................................................................................................................. 2
2. Product Appearance.................................................................................................................................................3
3. Specification.............................................................................................................................................................. 4
4. Installation.................................................................................................................................................................4
5. Setting up ZB11B......................................................................................................................................................5
5-1. Turn On/ Turn Off ZB11B..............................................................................................................................5
5-2. Join the ZigBee Network................................................................................................................................ 6
5-3. Binding............................................................................................................................................................6
5-4. Sleeping Mode................................................................................................................................................ 6
5-5. Wake up ZB11B..............................................................................................................................................7
5-6. Battery............................................................................................................................................................. 7
5-7. Infrared Sensor Detection and Report............................................................................................................ 7
5-8. Restore to Factory Setting...............................................................................................................................8
6. Home Automation Clusters for ZB11B..................................................................................................................9
7. Important Maintenance Instructions................................................................................................................... 11

2
1. Introduction
Netvox ZB11B, an infrared radiation (IR) motion sensor, acts as an End Device in ZigBee network. It does not
perform permit-join function as a coordinator or a router for other devices to join the network. When ZB11B
detects movement, it reports the message based on how bright the location is. Users can assign specific ON/OFF
task to the binding devices according to different report.
What is ZigBee?
ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and supports multiple
network topologies such as point-to-point, point-to-multipoint, and mesh networks. It is defined for a
general-purpose, cost-effective, low-power-consumption, low-data-rate, and easy-to-install wireless solution for
industrial control, embedded sensing, medical data collection, smoke and intruder warning, building automation
and home automation, etc.

3
2. Product Appearance
Indicator (Red/ Green)
Binding Key
Infrared Sensor
Auxiliary Key
Sensor Sensitivity Adjuster
Release Button
Light Sensitivity Adjustor

4
3. Specification
Fully IEEE 802.15.4 compliant (ZigBee Pro)
Utilizes 2.4GHz ISM band; up to 16 channels
Power supply: 2 x ER14505 3.6V AA batteries
Operating consumption: ≤ 45mA
Standby consumption: ≤ 100uA
Sensing angle- horizontal: 110°; vertical: 60°
Equipped with light sensor
Up to 70 meters wireless transmission range in non-obstacle space
Easy installation and configuration
4. Installation
A mounting height between 2 and 2.2 meters is recommended.
Do not aim the passive infrared sensor to a heat or cold source.
The sensor should not face open door/windows as sunlight will affect its operation.
The sensor must be mounted on a vibration-free surface.
IR coverage range:
The coverage area A- Distance: 12 meters; sensing angle: 30°.
The coverage area B- Distance: 8 meters; sensing angle: 60°.
The coverage area C- Distance: 5 meters; sensing angle: 110°.

5
5. Setting up ZB11B
5-1. Turn On/ Turn Off ZB11B
Under the circumstances ZB11B is first time used or after resetting, when it is powered on and cannot
successfully search a network, ZB11B will go into turn-off mode.
To manually turn on or turn off ZB11B, please use the following instructions:

6
A. Turn it on: Press the Binding Key once. The indicators will flash once, and the device is ready to be
used.
B. Turn it off: Press and hold the Binding Key for 15 seconds. The indicator will keep flashing. Release
the Binding Key, and the device would be turned off.
It is recommended that having a 5-second interval between turning on and turning off ZB11B.
5-2. Join the ZigBee Network
After ZB11B is turned on, it will search for an existing ZigBee network and send a request to join the network
automatically. While ZB11B is under the coverage from a coordinator or a router whose permit-join feature is
enabled, ZB11B will be permitted to join the network.
Step1. Enable the permit-join function (valid for 60 seconds) of a coordinator or a router (please refer to
the user manual of the coordinator or the router to enable the permit-join feature).
Step2. Turn on ZB11B. It will start to search and join the network.
Step3. The indicator will flash green once when it finds out a network to join.
Step4. The indicator will flash green 5 times after it is joined successfully. Otherwise, the indicator will
not flash.
5-3. Binding
To make ZB11B work with another device, users need to bind the two devices:
Step1. Press the Binding Key to broadcast the binding request. The indicator will flash green once.
Step2. The indicator flashes green 5 times after the binding is completed; otherwise, it flashes green 10
times.
5-4. Sleeping Mode
ZB11B is designed to go into sleeping mode for power-saving in some situations:
A. While the device is in the network → the sleeping period is 5 minutes; it will wake up every 5
minutes to keep online.
B. When it doesn’t find a network to join →ZB11B will go to sleeping mode. It will wake up every 15
minutes to search a network to join.
C. Once ZB11B was joined to a network and by any chance the network is no longer existed or the
device is out of the network →ZB11B will wake up every 15 minutes to find the network it joined
before.
It never keeps in sleeping mode and continues to find out a network every 15 minutes. This condition would
consume up to 30 times power spending compared to normal-operating status. To prevent this unwanted power
consumption, we recommend that users remove the batteries to power off the device.

7
5-5. Wake up ZB11B
When users would like to setup or acquire data from the device which is in sleeping mode, we have to wake
up the device as the following steps:
Step1. Press the Auxiliary Key.
Step2. The indicator flashes green 5 times when ZB11B is online.
Step3. ZB11B will broadcast the device data to the ZigBee network.
ZB11B would be in active status for 2 minutes for communication.
5-6. Battery
ZB11B will send a low-power report to the ZigBee network when the operating voltage is lower than 3.2V by
default.
The related data:
Power configuration cluster (ID:0x0001)
Battery voltage attribute (ID:0x0020)
The reporting voltage can be adjusted. There are 4 voltages for choosing: 3.5V/ 3.4V/ 3.3V/ 3.2V.
It is recommended that the minimal reporting internal is longer than 3-minute.
5-7. Infrared Sensor Detection and Report
When the infrared sensor detects a movement, ZB11B would send the ON task to the binding device based on
how bright the location is. The light sensitivity can be adjusted by user. After ZB11B sends the ON task, there
will be 2 conditions:
A. No additional movement is detected in 30 seconds → it sends the OFF task to the binding device.
B. Further movement is detected → the infrared sensor will be inactive for 21 seconds (30 seconds x 70%).
In the 22nd ~ 30th second, it sends the OFF task while no additional movement is detected; otherwise,
it goes to condition B again.
Users could change the light sensitivity by adjusting the Light Sensitivity Adjuster.
Clockwise adjustment → Send the task message in brighter location
Users could change the detecting sensitivity by adjusting the Sensor Sensitivity Adjuster.
Clockwise adjustment → Higher sensitivity
NOTE: After ZB11B is turned on, the infrared sensor is not active for 1 minute.

8
5-8. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Press and hold the Auxiliary Key for 10 seconds.
Step2. Release the button after the indicator shows fast green flashes to complete the restore.

9
6. Home Automation Clusters for ZB11B
A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A
simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table
lists the clusters which are supported by ZB11B.
1.End Point(s):0x01:
2.Device ID:HA On/Off Switch(0x0000)
3.EndPoint Cluster ID
Server side Client side
Mandatory
Basic(0x0000) On/Off Switch(0x0006)
Power configurationr(0x0001)
Identify(0x0003)
Commissioning(0x0015)
Poll control(0x0020)
Diagnostics Cluster(0x0B05)
This lists the attributes of the basic information.
Identifier Name Type Range Access Default Mandatory /
Optional
0x0000 ZCLVersion Unsigned
8-bit integer
0x00 –
0xff
Read only 0x03 M
0x0001 ApplicationVersion Unsigned
8-bit integer
0x00 –
0xff
Read only -- O
0x0002 StackVersion Unsigned
8-bit integer
0x00 –
0xff
Read only -- O
0x0003 HWVersion Unsigned
8-bit integer
0x00 –
0xff
Read only -- O
0x0004 ManufacturerName Character
string
0 – 32
bytes
Read only netvox O
0x0005 ModelIdentifier Character
string
0 – 32
bytes
Read only ZB11BE3E
D
O
Table of contents
Other netvox Accessories manuals

netvox
netvox R718DB User manual

netvox
netvox R718N3 User manual

netvox
netvox RB11E User manual

netvox
netvox R718PA8 User manual

netvox
netvox R718DA2 User manual

netvox
netvox R313CA User manual

netvox
netvox R311LA User manual

netvox
netvox R718PB15A User manual

netvox
netvox R718CXAB User manual

netvox
netvox R718B1 Series User manual

netvox
netvox R311FA User manual

netvox
netvox R718UBB Series User manual

netvox
netvox R718PG-AS923 User manual

netvox
netvox R311D User manual

netvox
netvox R718N1 User manual

netvox
netvox R72616A User manual

netvox
netvox R718EA User manual

netvox
netvox R718PQA User manual

netvox
netvox R718F User manual

netvox
netvox Z713 User manual