MEFE CAT 679178 User manual

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 1
+617 3283 4536
Free AU 1800 669 006
Revision 3
Installaon Manual
Automac Sensor Tap
Deck Mounted
CAT 679178 CAT 679178S CAT 679178B
Stainless Steel Polished Stainless Steel San Mae Black

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 2
+617 3283 4536
Free AU 1800 669 006
Product Descripon
• This sensor tap is designed to turn on with sensor acvaon and o when hands are removed.
• Features a micro-computer infrared sensor control module, low consumpon microprocessor chip with stable perfor-
mance and high an-interference.
• Automacally calibrates sensing range according to the environment and stores this into the electronic chip.
• A water saving aerator is used in the faucet to prevent water splash back and allow for a so ow.
• Supplied with both AC 240V Transformer and DC 6V Baery Pack.
• The faucet has been precisely manufactured and tested, ensuring the quality of the product sases internaonal
standards.
Pre-Install Instrucons
Please choose an appropriate basin before installaon, avoid basins with strong reecve surfaces.
Please ensure all pipes have been ushed for at least 60 seconds and are clear of dirt and impuries (water must be clear).
Installaon must be in accordance with the Naonal Plumbing and Drainage standard – AS/NZS 3500.
Sensing Range
The sensor tap will automacally calibrate the sensing range when rst connected to power. Please ensure the tap has been
installed in the correct and nal posion before connecng to power. When connected to power the sensing light will ash
indicang it is in programming mode, please do not interfere or obstruct for at least 60 seconds.
Specicaons
*To reprogram sensing range use oponal remote 673-100R.
WaterMark Cered
Australia and New Zealand WaterMark cered with approved licence number WM-022559.
6 Star WELS Rang
This guarantees that the product is in accordance with the standard set under the Naonal Water Eciency Labelling and
Standards and has the highest possible water eciency rated 6 Stars. Licence number 1718.
DDA Compliant
Suitable for use for AS 1428.1 design and access requirements when installed in reference to AS 1428.1 2009 Amendment 1
and the intent of the Disability Discriminaon Act (DDA).
Power AC 240V or DC 6V 4 x AA alkaline baer-
ies (baeries not supplied)
Installaon Diameter Single hole (32mm)
Baery Life 150,000 cycles Response Time Less than 0.7 seconds
Sensing Range Products before SN: 11044
Default approximately 10cm
Products including and after SN: 11044
Default approximately 10cm
Reprogrammed with remote achieves
min 0 to 5 or max 0 to 20cm*
Water Stop Protecon (Auto
Shut O)
Approx. 30—60 seconds
Working Temperature 1°C - 60°C Flow Rate Less than 3 L/s at 0.3Mpa
Working Pressure 0.07Mpa—0.7Mpa Ambient Humidity 95% or less
Inlet Size BSP 1/2” (DN15) male thread Faucet Body Material 304 Stainless Steel

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 3
+617 3283 4536
Free AU 1800 669 006
Choosing the Correct Basin
IMPORTANT:
Please avoid stainless steel and other highly reecve basins as these reecons can cause interference with the sensor.
Warning: Sensor of the faucet must be higher than the basin or lavatory. Minimum of 15mm.

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 4
+617 3283 4536
Free AU 1800 669 006
Installaon

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 5
+617 3283 4536
Free AU 1800 669 006
Installaon Cont.
Oponal: Hot and Cold Mixer
2 x Watermarked
Braided Hoses
(exible) with a DN15
nut on both ends
(673-058L 120cm /
673-058 100cm)
1 x Watermarked
Mixer Valve (CAT 67
M2)

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 6
+617 3283 4536
Free AU 1800 669 006
Fault Check
Our sensor tap range is primarily divided into three components: the sensor, the solenoid valve, and the power supply. The
solenoid valve and power supply are universal and interchangeable parts across our range of same type taps. The sensor is
specic to each spout type.
If you have other sensor taps or spare parts available it can be helpful to trouble shoot by swapping parts unl the faulty part is
idened.
Cleaning and Maintenance
Regular cleaning is essenal to keep your tap looking its best.
Do not rinse the control box with water.
Do not use abrasive or chemical cleaners (including chlorine to
clean the faucet as this can dull lustre and nish of the tap).
Wash only with soap water and dry with a clean so towel or microbre
cloth.
When cleaning the general area please ensure you protect the faucet from any cleaning acids or uids as this can discolour or
remove the chrome plang where applicable.
The lter screen on the solenoid valve inlet should be cleaned regularly to avoid excessive blockage and obstrucon caused by
impuries resulng in low water ow.
Issue Cause
No water ow Check the power supply: if using baeries, carefully check the correct polarity of the baer-
ies and replace. The sensor light should ash indicang the tap is entering programming
mode.
No water ow Check the sensor: Aer conrming power is OK, if the sensor light does not ash, replace
the sensor.
No water ow Check the solenoid valve: place your hands under the faucet, you should hear a click of the
solenoid valve indicang the sensor is working normally. This means water is not supplied or
unable to ow. Check the solenoid valve for obstrucon—the solenoid diaphragm may be
blocked. Opening and cleaning the solenoid may be necessary, or replace the solenoid
valve.
Low water ow Check the solenoid valve: A leaking faucet with a constant slow ow indicates the dia-
phragm is not sealing due to debris or it may be cracked or town. Replace the diaphragm or
Intermient water ow Check the sensing range: This is most likely caused by a failure to program sensing range
correctly due to interference from a reecve basin. We recommend you remove power for
2 minutes, then reconnect and allow the sensor to adjust to a short sensing range. It can be
benecial to place cardboard at the boom of the basin when recalibrang the sensing
range to remove interference from strong reecons.
Water does not stop owing Check the solenoid valve: If the faucet does not stop owing it may be that the solenoid
valve is faulty and should be replaced. The diaphragm is not sealing due to debris or it may

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 7
+617 3283 4536
Free AU 1800 669 006
CAT 679178 | CAT 679178S | CAT 679178B

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 8
+617 3283 4536
Free AU 1800 669 006
No. Part # Descripon Material No. Part # Descripon Material
1. 679-800 Faucet Body SUS 304 Stainless Steel 9. 673-058L Braided Hose SUS 304 Stainless WMKA21506
2. 673-033B Rubber Mat NBR Rubber 10. 679-120 Housing ABS Plasc
3. 673-033 Aerator POM Plasc 11. 679-121 Baery Box ABS Plasc
4. 673-033D Spout Shell SUS 304 Stainless Steel 12. 679-120 Housing ABS Plasc
5. 679-131 Sensor Electronic Hardware 13. 679-122 Solenoid Valve POM Plasc + SUS 304 S/Steel
6. 679-107C Cover SUS 304 Stainless Steel 14. 679-127 Screw SUS 304 Stainless Steel
7. 679-116 Rubber Mat NBR Rubber 15. 679-128 Power Adaptor Electronic Hardware
8. 679-118 Copper Nut Brass 16. N/A N/A N/A
1
2
3
4
5
6
7
8
9
10
12
This manual suits for next models
2
Table of contents
Other MEFE Plumbing Product manuals
Popular Plumbing Product manuals by other brands

Weka
Weka 506.2020.00E ASSEMBLY, USER AND MAINTENANCE INSTRUCTIONS

Kohler
Kohler K-6228 Installation and care guide

UBERHAUS DESIGN
UBERHAUS DESIGN 75175017 Operator's manual

American Standard
American Standard DetectLink 6072121 manual

Uponor
Uponor Contec TS Mounting instructions

Pfister
Pfister Selia 49-SL Quick installation guide

Kohler
Kohler Centerset K-15240 Homeowner's guide

Viega
Viega Prevista Dry 8522.33 Instructions for use

Sanela
Sanela Lema SLP 59RB Instructions for use

Elkay
Elkay EDF15AC Installation, care & use manual

Hans Grohe
Hans Grohe AXOR Citterio E 36702000 Instructions for use/assembly instructions

baliv
baliv WT-140 manual