Quick Start Guide Side Opening Mid-Sized External Housing with Heater and PoE
4
AC Power Connection
Shows how to connect the AC power cord to the TB. 1 connector. This is spare for
AC power source input/output for AC accessory, it may not necessary to use in PoE
enclosure.
Installation
If you plan to install this camera into a tropical, sear coastal, saltwater or corrosive
industrial water/moist environment, please seal each stainless steel screw and
fittings with a silicon grease compounds. This will help prevent electrolysis
corrosive occurring and extend the lifespan of the camera and housing.
Caution :
1. UTP Category 5 cable is recommended to field construction.
2. Input CAT 5 wire must be 8 core line with standard RJ45 male connector.
3. A workable length is not exceed 100 Meters CAT 5 cable from PoE Hub Switch
to TPH-4000P, no guarantee if CAT5 cable beyond 100 Meters.
4. The second heater & IR illuminator are option and IEEE802.3at Injector
(TPH948/IJ) is necessary to connect in between PoE hub switch and PoE
enclosure.
RJ45 In/Out Pin Define & Connection
1. PoE Hub Switch end point with 48VDC output is an IEEE802.3af regulation de-
vice through pin 4,5,7,8 or 1,2,3,6 power device (PD).
2. An IEEE802.3at regulation power source equipment (PSE), a PoE injector is
strongly recommend to connect in between PoE hub switch and PoE housing.