Furuno SSAS User manual

SHIP SECURITY ALERT SYSTEM (SSAS)

1
TABLE OF CONTENTS
SYSTEM CONFIGURATION.........................................................................................2
1.
OVERVIEW OF SSAS..............................................................................................4
2.
INSTALLATION.........................................................................................................6
2.1 Mounting ......................................................................................................................... 6
2.1.1 Junction box (for FELCOM 16) ............................................................................... 6
2.1.2 SSAS alert unit ....................................................................................................... 7
2.2 Wiring.............................................................................................................................. 9
2.2.1 Junction box (for FELCOM 16) ............................................................................... 9
2.2.2 SSAS alert unit ..................................................................................................... 10
2.3 Initial Settings................................................................................................................ 11
3.
OPERATION............................................................................................................12
3.1 Operation Mode ............................................................................................................ 12
3.1.1 Changing the password ........................................................................................ 12
3.1.2 SSAS manager mode........................................................................................... 13
3.2 Setting SSAS Report Destination and Message Contents............................................. 14
3.3 Transmitting SSAS Report ............................................................................................ 17
3.4 Testing the Button ......................................................................................................... 19
3.5 SSAS Report Test ......................................................................................................... 23
OUTLINE DRAWING.................................................................................................D-1
INTERCONNECTION DIAGRAM .............................................................................S-1

2
SYSTEM CONFIGURATION
Regulations require at least two SSAS units.
FELCOM 15
Printer
PP-510
ANTENNA
UNIT
IC-115
TERMINAL UNIT
IC-215
JUNCTION
BOX
IC-315
Navigator
100/115/220/230 VAC
1φ, 50/60 Hz
: Standard Supply
: Option
: Local Supply
12/24
VDC *1
AC-DC Power Supply
PR-240-CE*2
*1 For 12VDC,
DC-DC converter is
required to use PP-510.
*2 Any AC-DC power supply
fulfilling requirements of
IEC 60945 may be used.
Distress Message Controller
DMC-5
Personal
Computer
(PC/AT compatible)
EGC Printer
PP-50
Shipboard LAN (Ethernet)
GPS receiver
OP16-24
Mini Keyboard
DGPS
CATEGORY OF UNITS
Unit Category
Terminal Unit Protected from weather
Antenna Unit Exposed to weather
Other Units Protected from weather
Distress Alert/
Received Call Unit
IC-305
Alarm Unit
IC-306
24 VDC
Printer
SSAS Alert Unit
IC-307
O
SSAS Alert Unit
IC-307
(Max. 3 units)

3
FELCOM 16
Antenna Unit Exposed to Weather
Communication Unit Protected from Weather
Other Units Protected from Weather
PERSONAL
COMPUTER
(PC/AT compatible)
ANTENNA
UNIT
IC-116
COMMUNICATION UNIT IC-216
(with internal GPS receiver)
100/115/220/230 VAC
1φ, 50/60 Hz
: Standard
: Option
: Local Supply
: SSAS only
12-24 VDC
AC-DC
Power Supply
PR-240-CE*
POWER
I
O
INMARSAT MINI-C MOBILE EARTH STATION
FURUNO
POWER
LOGIN
TX
ERROR
PRINTER
JUNCTION BOX
IC-315
SSAS ALE T UNIT
IC-307
SSAS ALE T UNIT
IC-307
CATEGORY OF UNITS
(Max. 3 units)
* Any AC-DC power supply
fulfilling requirements of
IEC 60945 may be used.

4
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15 or the Inmarsat Mini-C FELCOM 16 for the purpose of alerting specified
addresses (for example, your ship’s company) that your ship is under attack by intruders.
The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed before 01
July 2004 to install an SSAS.
When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.
The SSAS is protected with a password to prevent unauthorized setting or testing of it by
other than the ship’s captain or authorized personnel.
Headquarters
Ship
Ship’s Company,
Management Company
Inmarsat System
Ship Name, MMSI No.,
Ship Position, etc.

5
SSAS operation flow
1.
Open the cover of the button and then press the button.
(This is a latch-type button; hit and release to activate the button.)
2.
If addresses have been preset, the SSAS report is sent to one
address 30 seconds after the button is activated.
(Max. 5 addresses)
(You may cancel transmission of the SSAS report by pressing the
button again with 30 seconds of the initial press.)
3.
An LES sends acknowledgement to your ship.
4.
Steps 2-3 and are repeated in case of multiple addressees.
5.
Continuous transmission of the SSAS report begins.
(The interval at which to transmit the SSAS report to each address
can be specified. The SSAS report is continuously transmitted
while the button is ON, at the interval selected.)
¯
¯
¯
¯
6.
To stop transmission, press the button again to deactivate it.
(This is only possible in the SSAS manager mode. See
paragraph 3.1.)

6
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16)
The junction box IC-315 is required when installing the SSAS on the FELCOM 16; it is
already installed on the FELCOM 15.
Separate the junction box from a magnetic compass by the distances shown below to
prevent deviation to a magnetic compass.
Standard compass: 1.0 m
Steering compass: 0.7 m
1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.
120
±
0.5
70
±
0.5
Junction box IC-315
The junction box is connected to the communication unit with a 2 meter cable, with D-sub
connector (at the communication unit). Therefore, locate the junction box within two meters
of the communication unit.

7
2.1.2 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviation to a magnetic compass.
Standard compass: 0.70 m
Steering compass: 0.45 m
Locate the SSAS alert unit where it cannot be found by intruders. The location should be
known only by ship’s captain and authorized personnel.
Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.
otate
Fasten three screws.
Clamp
4. Run the cable thru one of the cable entrances and connect it to terminal board.

8
5. Attach the switch cover as shown below. Note that the cover may also be rotated 180
degrees.
Switch cover
Press here and hold down for five seconds.
Flush mounting
The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.
Name Type Code No. Qty Remarks
Fixture 16-018-7201 100-317-930 1
Pan head screw M3x6 000-800-362 4
Self-tapping screw 4x16 000-802-080 4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied).
3. Fasten the fixture with the unit to the mounting location with four self-tapping screws
(supplied).
4. Attach switch cover as shown above.

9
2.2 Wiring
2.2.1 Junction box (for FELCOM 16)
Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16. Unfasten
four screws to remove the cover to connect cables to terminal board. For detailed wiring
information see the interconnection diagram.
For connection, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view
of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV-SB-C 0.2x5P
cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with the
junction box.
Cover
Terminal
board
Communication
Unit
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
Core 7 mm
1
2
3
Vcc
GND
TD/RD-A
TD/RD-B
NC
TD-A(NAV)
TD-B(NAV)
RD-A(NAV)
RD-B(NAV)
GND
DMC OUT-H
DMC OUT-C
DMC IN-H
DMC IN-C
DMC CTR
IC-305/306
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Cable clamp
(top)
Note 1: Do not insert the cable too
deeply, to prevent pinching the sheath.
Note 2: Pull each cable slightly to con-
firm that they are in their holes securely.
90mm15mm 7mm
16S0344
Fold back braided shield onto
sheath and fix by cable clamp.
Cable clamp Cable clamp
(bottom)
Junction box IC-315
Table of contents
Other Furuno Security System manuals

Furuno
Furuno BR-500 User manual

Furuno
Furuno FELCOM16 User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno IC-307 User manual

Furuno
Furuno FB-3101 User manual

Furuno
Furuno IC-350 User manual

Furuno
Furuno felcom15 User manual

Furuno
Furuno BR-1000 User manual

Furuno
Furuno BR-1000 User manual
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual