Furuno felcom15 User manual

SHIP SECURITY ALERT SYSTEM (SSAS)
(For FELCOM12/15/16)

The paper used in this manual
is elemental chlorine free.
FURUNO Authorized Distributor/DealerFURUNO Authorized Distributor/Dealer
9-52 Ashihara-cho,9-52 Ashihara-cho,
Nishinomi
y
a 662-8580, JAPANNishinomi
y
a 662-8580, JAPAN
Tele
p
hone :Tele
p
hone : 0798-65-21110798-65-2111
FaxFax 0798-65-42000798-65-4200
::
FIRST EDITION :FIRST EDITION :MAY.MAY. 20042004
Printed in JapanPrinted in Japan
A
ll ri
g
hts reserved.
A
ll ri
g
hts reserved.
DD :: SEP.SEP. 09, 200509, 2005
Pub. No.Pub. No. OME-56351OME-56351
*
00015035913
*
*
00015035913
*
*
00015035913
*
*
00015035913
*
(( DAMIDAMI )) IC-307(SSAS)IC-307(SSAS) * 0 0 0 1 5 0 3 5 9 1 3 ** 0 0 0 1 5 0 3 5 9 1 3 *
*
OME
56351
D
00
*
*
OME
56351
D
00
*
*
OME
56351
D
00
*
*
OME
56351
D
00
*
* O M E 5 6 3 5 1 D 0 0 ** O M E 5 6 3 5 1 D 0 0 *

1
TABLE OF CONTENTS
SYSTEM CONFIGURATION.........................................................................................2
1. OVERVIEW OF SSAS..............................................................................................4
2. INSTALLATION.........................................................................................................6
2.1 Mounting ......................................................................................................................... 6
2.1.1 Junction box (for FELCOM 16) ............................................................................... 6
2.1.2 I/F box IC-312 (for FELCOM 12)............................................................................. 7
2.1.3 SSAS alert unit ....................................................................................................... 8
2.2 Wiring............................................................................................................................ 10
2.2.1 Junction box (for FELCOM 16) ............................................................................. 10
2.2.2 I/F box IC-312 (for FELCOM 12)........................................................................... 11
2.2.3 SSAS alert unit ..................................................................................................... 12
2.3 Initial Settings................................................................................................................ 13
3. OPERATION............................................................................................................14
3.1 Operation Mode ............................................................................................................ 14
3.1.1 Changing the password ........................................................................................ 14
3.1.2 SSAS manager mode ........................................................................................... 15
3.2 Setting SSAS Report Destination and Message Contents............................................. 16
3.3 Transmitting SSAS Report ............................................................................................ 19
3.4 Testing the Button .........................................................................................................21
3.5 SSAS Report Test ......................................................................................................... 27
OUTLINE DRAWINGS...............................................................................................D-1
INTERCONNECTION DIAGRAMS...........................................................................S-1

2
SYSTEM CONFIGURATION
Regulations require at least two SSAS alert units.
FELCOM 15
Printer
PP-510
ANTENNA
UNIT
IC-115
TERMINAL UNIT
IC-215
JUNCTION
BOX
IC-315
Navigator
100-115/200-230 VAC
1φ, 50/60 Hz
: Standard Supply
: Option
: Local Supply
AC-DC Power Supply
PR-240-CE*1
*1 Any AC-DC power supply
fulfilling requirements of
IEC 60945 may be used.
Personal
Computer
(PC/AT compatible)
EGC Printer
PP-50
Shipboard LAN (Ethernet)
GPS receiver
OP16-24
Mini Keyboard
DGPS
Distress Alert/
Received Call Unit
IC-305
Alarm Unit
IC-306
24 VDC
Printer
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
(Max. 3 units)
SSAS Alert Unit
IC-307
12-24 VDC
24 VDC
24 VDC
FELCOM 16
: Standard
: Option
: Local Supply
PRINTER
ANTENNA
UNIT
IC-116
COMMUNICATION UNIT IC-216
(with internal GPS receiver)
AC-DC
Power Supply
PR-240-CE
PERSONAL
COMPUTER
(PC/AT compatible)
POWER
I
O
INMARSATMINI-C MOBILE EARTH STATION
FURUNO
POWER
LOGIN
TX
ERROR
JUNCTION BOX
IC-315
100-115/200-230 VAC
1φ, 50/60 Hz
12-24 VDC
24 VDC
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
(Max. 3 units)
SSAS Alert Unit
IC-307

3
FELCOM 12
Navigator
: Standard
: Option
: User Supply
INMARSAT-C MOBILE EARTH STATION
POWER
ON OFF
POWER BRIGHT CONTRAST
Antenna Unit
IC-112
Terminal Unit
IB-581/IB-582
24 VDC
Communication
Unit
IC-212
Mini Keyboard
24 VDC
Priinter
PP-510
24 VDC
100/110/200/220V
1φ, 50/60 Hz AC-DC
Power Supply
PR-300
Distress Alert Unit
IC-302
Received Call Unit
IC-303
Distress Alert Unit
IC-302
OR
Distress Message Controller
DMC-5 24 VDC
PC
(PC/AT compatible)
OR
Terminal Unit
IB-581/IB-582
SSAS Alert Unit
IC-307
SSAS Alert Unit
Interface
IC-312
24 VDC
SSAS Alert Unit
IC-307 (Max. 3 units)
SSAS Alert Unit
IC-307

4
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15/FELCOM 12 or the Inmarsat Mini-C FELCOM 16 for the purpose of alerting
specified addresses (for example, your ship’s company) that your ship is under attack by
intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed
before 01 July 2004 to install an SSAS.
When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.
The SSAS is protected with a password to prevent unauthorized setting or testing of it by
other than the ship’s captain or authorized personnel.
Headquarters
Ship
Ship's Company,
Management Company
Inmarsat System
Ship Name, MMSI No.,
Ship Position, etc.

5
SSAS operation flow
1.Open the cover of the button and then press the button.
(This is a latch-type button;hit and release to activate the button.)
2.If addresses have been preset, the SSAS report is sent to one
address 30 seconds after the button is activated.
(Max. 5 addresses)
(You may cancel transmission of the SSAS report by pressing the
button again within 30 seconds of the initial press.)
3.An LES sends acknowledgement to your ship.
4.Steps 2-3 and are repeated in case of multiple addressees.
5.Continuous transmission of the SSAS report begins.
(The interval at which to transmit the SSAS report to each address
can be specified.The SSAS report is continuously transmitted
while the button is ON, at the interval selected.)
↓
↓
↓
↓
6.To stop transmission, press the button again to deactivate it.
(This is only possible in the SSAS manager mode. See
paragraph 3.1.)

6
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16)
The junction box IC-315 is required when installing the SSAS on the FELCOM 16; it is
already installed on the FELCOM 15.
Separate the junction box from a magnetic compass by the distances shown below to
prevent deviation to a magnetic compass.
Standard compass: 1.0 m
Steering compass: 0.7 m
1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.
120 ±0.5
70 ±0.5
Junction box IC-315
The junction box is connected to the communication unit with a 2 meter cable, with D-sub
connector (at the communication unit). Therefore, locate the junction box within two meters
of the communication unit.

7
2.1.2 I/F box IC-312 (for FELCOM 12)
The I/F box is required to connect the SSAS alert unit to the FELCOM 12.
The I/F box is connected to the communication unit with a 5 m cable (17JE-573-10 harness).
Accordingly, locate the interface within 5 m of the communication unit.
Keep the following compass safe distances in mind when choosing the mounting location:
Standard compass: 0.65 m
Steering compass: 0.45 m
1. Unfasten four screws to remove the cover.
2. Use four self-tapping screws (3X10, supplied) to fix the unit to the mounting location.
3. If the cable is led in from the rear of the unit, change the clamp location as follows:
a) Unfasten two screws to remove the clamp.
b) Turn the clamp 90 degrees.
c) Fasten the clamp.
Unfasten two screws.
Turn
Fasten clamp with two screws.
Clamp
4. Pass the cable through the clamp and connect it to the terminal board, referring to the
interconnection diagram.

8
2.1.3 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviation to a magnetic compass.
Standard compass: 0.70 m
Steering compass: 0.45 m
Locate the SSAS alert unit where it cannot be found by intruders. The location should be
known only by ship’s captain and authorized personnel.
Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.
Rotate
Fasten three screws.
Clamp
4. Run the cable thru one of the cable entrances and connect it to terminal board.
Other manuals for felcom15
1
This manual suits for next models
2
Table of contents
Other Furuno Security System manuals

Furuno
Furuno FB-3101 User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno FELCOM16 User manual

Furuno
Furuno SSAS User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno IC-307 User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno IC-350 User manual

Furuno
Furuno BR-1000 User manual

Furuno
Furuno BR-1000 User manual
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual