Eneo MPP-62A0020M0B User manual

EN
DE
FR
IT
Quick Installation Guide
1/2.8” HD Analogue Dome, PTZ,
Day&Night, 20x, 4,7-94mm,
1920x1080, WDR, IP66
MPP-62A0020M0B

2
Contents
Components...................................................................................................................5
Installation.....................................................................................................................6
Installation...........................................................................................................................................................................6
Locking the Dome Camera.......................................................................................................................................7
Basic Configuration of Dome Camera System........................................................................................................8
Setting Dome Camera (DIP Switch)............................................................................................................................9
Connections .................................................................................................................................................................... 10
Connecting to the RS-485 .....................................................................................................................................10
Connecting HD Output connector .................................................................................................................... 10
Connecting CVBS Output connector ................................................................................................................10
Connecting Alarms...................................................................................................................................................10
Connecting the Power ...........................................................................................................................................10
Getting Started ...........................................................................................................................................................11

3
EN
Safety instructions
General safety instructions
• Before switching on and operating the system, rst read this safety advice and the operating instructions.
• Keep the operating instructions in a safe place for later use.
• Installation, commissioning and maintenance of the system may only be carried out by authorised
individuals and in accordance with the installation instructions - ensuring that all applicable standards and
guidelines are followed.
• Protect the devices from water penetration and humidity, since these can cause lasting damage.
• Should moisture nevertheless enter the system, under no circumstance switch on the devices under these
conditions, instead send them for examination to an authorised specialist workshop.
• The system must never be used outside of the technical specications, since this can destroy it.
• The device must be protected from excesses of heat, dust, humidity and vibration.
• When separating the system from the voltage supply, only ever use the plug to pull out the cable. Never
pull directly on the cable itself.
• Lay the connecting cables carefully and check that they are not mechanically stressed, kinked or damaged
and that no humidity can penetrate into them.
• In the event of a malfunction, please inform your supplier.
• Maintenance and repairs may only be carried out by authorised specialist personnel.
• The system must be isolated from the power supply before opening the housing.
• The device may only be opened by qualied service personnel. Unauthorised access invalidates any
warranty claim.
• Connection cables should always be exchanged through Videor E. Hartig GmbH.
• Use only original spare parts and accessories from Videor E. Hartig GmbH.
• The housing should only be cleaned using a mild domestic cleaning agent. Never use solvents or petrol as
these can permanently damage the surface.
• During installation, it is essential to ensure that the seals provided are correctly installed and that they are
not displaced during installation. Damaged seals must not be installed and will invalidate any warranty.
• The installer is responsible for the maintenance of the enclosure as per the technical data, e.g. by sealing
the cable outlets with silicone.
• Wire end ferrules should be used when shortening the exible connection cables.
• The devices may only be operated in the temperature range indicated in the data sheet and within the
dened air humidity range.
Product - Specic Safety Instructions
• The camera may never be pointed directly at the Sun with the aperture open (this will destroy the sensor).
• It is unavoidable that during manufacture and to a certain extent during later use, humidity will be present
in the ambient air within the device’s housing. In the event of large temperature uctuations, this humidity
may condense inside the housing.
• To avoid this condensation inside the very tightly sealed housing, the manufacturer has inserted silica gel
sachets in the housing of the various camera types.
• It is however a physical given, that these silica gel bags will reach saturation after a certain amount of time.
They should therefore be replaced with new silica gel sachets.
• During installation, it is essential to ensure that the seals provided are correctly installed and that they are
not displaced during installation. Damaged seals must not be installed and will invalidate any warranty.
• A multipolar, easily accessible isolation device should be installed in the proximity of the IR Spotlight, in
order to disconnect the device from the power supply for service work.
• The earth connection must be made according to the low impedance requirement of DIN VDE 0100.
• Subsequent painting of the equipment surface can impair the function.
• Any warranty claim is invalidated by subsequent painting.
• A safety margin of > 1m from the spotlight must be maintained when viewing directly into the IR Spotlight
in a darkened environment.
• Do not look directly at invisible LED radiation using optical instruments (e.g. a reading glass, magnifying
glass or microscope), since this can endanger the eyes, LED Class 1M.
• Operation of the IR spotlight with a defective cover or during repair is prohibited.

4
Class A device note
This is a Class A device. This device can cause malfunctions in the living area; in such an event, the operator may
need to take appropriate measures to compensate for these.
WEEE (Waste Electronical & Electronic Equipment)
Correct Disposal of This Product (Applicable in the European Union and other European countries with separate
collection systems).
This marking shown on the product or its literature, indicates that it should not be disposed with
other household wastes at the end of its working life. To prevent possible harm to the environment
or human health from uncontrolled waste disposal, please separate this from other types of wastes
and recycle it responsibly to promote the sustainable reuse of material resources. Household users
should contact either the retailer where they purchased this product, or their local government
oce, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase
contract. This product should not be mixed with other commercial wastes for disposal.
Graphical symbols
Please pay attention to the safety instructions, and carefully read through this instruction guide before initial
operation.
Important points of warning are marked with a caution symbol.
iImportant points of advice are marked with a notice symbol.

5
EN
Components
This system comes with the following components;
• Dome Camera
• Installation Guide (optional)
• Template Sheet
• Mounting Bracket
• Safety Lanyard
• Mounting screws (PH6x35.0) x4
• Plastic anchors x4
• O-Rings x4
• Torx wrench x1
• 2-pin terminal block
• 3-pin terminal block
• 4-pin terminal block
• 5-pin terminal block
NOTICE: Check your package to make sure that you received the complete system,
including all components listed above.
NOTICE: Adaptor for 12VDC & 24VAC is not supplied.
i
i

6
Installation
Installation
The dome camera is for use in surface or pendent mounting applications, and the mount-
ing member must be capable of supporting loads of up to 4.5 kg. (Pendent mounting
must use pendent mount accessory.)
The dome cameras mounting bracket should be attached to a structural object, such as
hard wood, wall stud or ceiling rafter that supports the weight of the dome camera.
CAUTION: A silicone rubber sealant must be applied to seal the housing to secure
water-proofing.
CAUTION: Please reset the camera after 30 ~ 60 minutes when installing it in situations
colder than -10°C.
Plastic Anchors (4x)
Mounting Bracket (1x)
Mounting Screws (4x)
Safety Lanyard (1x)
Dome Bracket (1x)

7
EN
Locking the Dome Camera
1. Make screw holes on the ceiling using the supplied mounting Template Sheet (Figure A).
2. Fix the Mounting Bracket to the ceiling using supplied Anchors (4x) and Mounting Screws
(4x) (Figure B).
3. Hook up the Safety Lanyard to the Safety Lanyard Hook of the Mounting Bracket
(Figure C).
4. Align the locking tab on the bracket and the locking slot on the base of the dome
(Figure D).
5. Turn the dome to the counterclockwise about 10 degree to the locked position (Figure E).
Template Sheet
Safety Lanyard Hook
Mounting Bracket
Locking Tab
Safety Lanyard
Locking Slot
Locking Tab
Locking Slot
Locking Screw

8
CAUTION: Before installing mounting bracket to surface pre-adjust the four mounting
screws ”A” on the base of the dome camera to best match the mounting bracket locked
position. Unscrew the locking screw on the side of the dome’s base and t the tab of the
mounting bracket into the locking slot. Screws ”A” should not be too tight or too loose
when the dome is in the locked position. After setting the proper positions of screws
”A”remove the mounting bracket and install it to the proper surface. If it is too dicult
to lock the dome in position after the mounting bracket has been installed readjust the
screws ”A” by unscrewing them a small amount and try to install dome camera again.
Basic Configuration of Dome Camera System
No. Connector Description
13-pin terminal block CAMERA POWER
22-pin terminal block
TX+: RS485+ (A)
TX-: RS485- (B)
35-pin terminal block
A1: ALARM INPUT 1
A2: ALARM INPUT 2
A3: ALARM INPUT 3
A4: ALARM INPUT 4
GND
44-pin terminal block
AO1: ALARM OUTPUT 1
GND
AO2: ALARM OUTPUT 2
GND
5BNC black HD OUTPUT
6BNC yellow CVBS OUTPUT
The dome camera must be installed by qualified service personnel in accordance with all
local and federal electrical and building codes.

9
EN
Setting Dome Camera (DIP Switch)
NOTICE: Open the DIP switch cover and change the setting of DIP switch. After changing
the setting, close the cover tightly to ensure waterproong.
– S1 – S2
You can set video signal with D1 and video type with D2 in S1.
S1-D1 Video Signal S1-D2 Video Type
OFF HD-TVI Output OFF NTSC
ON AHD Output ON PAL
You can set coaxitron protocol with D3 and D4 in S1.
S1-D3 S1-D4 HD-TVI Output AHD Output
OFF OFF Hikvision-C ACP-PTZ
ON OFF Pelco-C Reserved
OFF ON Reserved Reserved
ON ON Reserved Reserved
You can set CVBS output with D1 in S2.
S2-D1 WDR Type WDR Control CVBS Output HD Output
OFF True WDR OFF Enabled Enabled
ON Disabled Enabled
ON Digital WDR OFF Enabled Enabled
ON Enabled Enabled
DIP Switch
i

10
Connections
Connecting to the RS-485
The dome camera can be controlled remotely by an external device or control system,
such as a control keyboard, using RS-485 half-duplex serial communications signals.
Connecting HD Output connector
Connect the HD output (BNC) connector to the video input.
Connecting CVBS Output connector
Connect the CVBS output (BNC) connector to the video input.
Connecting Alarms
A1,A2,A3,A4 (Alarm Input 1,2,3,4)
You can use external devices to signal the dome camera to react on events. Mechanical or
electrical switches can be wired to the A1,A2,A3,A4 (Alarm Input 1,2,3,4) and G (Ground)
connectors.
G (Ground)
iNOTICE: All the connectors marked G or GND are common.
Connect the ground side of the alarm input and/or alarm output to the G (Ground)
connector.
AO1,AO2 (5VTTL Alarm Output 1,2)
The dome camera can activate external devices such as buzzers or lights. Connect the
device to the AO1,AO2 (Alarm Output 1,2) and G (Ground) connectors.
Connecting the Power
Connect power of 12VDC or 24VAC for the dome camera. When using a 12VDC adapter,
connect the positive (+) pole to the‘+’position and the negative (-) pole to the‘-’ position.
Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certied/Listed Class 2 power source
only. 24VAC is recommended to use for the camera power for stable operation with heat-
er kit. If using 12VDC, the heater will not operate at all.
CAUTION:
• Be careful not to reverse the polarity when you connect
the power cable.
Table of contents
Languages:
Other Eneo Security Camera manuals

Eneo
Eneo EDCH/143E/C User manual

Eneo
Eneo TPP-72A0030P0A User manual

Eneo
Eneo PXB-2080MIR D User manual

Eneo
Eneo VKC-1370/12-24 User manual

Eneo
Eneo ENC-1001L User manual

Eneo
Eneo NXC-1502M User manual

Eneo
Eneo VKC-1425 User manual

Eneo
Eneo VKC-1374-1/IR User manual

Eneo
Eneo IPD-73M2812M0A User manual

Eneo
Eneo IPC-53M2812M0A User manual

Eneo
Eneo IPP-82A0030MIA User manual

Eneo
Eneo VKC-1340/IR User manual

Eneo
Eneo DOME-S1 User manual

Eneo
Eneo IPD-68M3611P5A User manual

Eneo
Eneo IPP-88A0030MIA User manual

Eneo
Eneo IPB-62M2712M5A User manual

Eneo
Eneo IPP-83A0036MIA User manual

Eneo
Eneo VKCD-1324B/IR User manual

Eneo
Eneo IPD-52M2713MAA User manual

Eneo
Eneo ICB-73M2712MWA User manual