Dyson AB09 User manual

Issued July 13
dyson
diagnostic Service manual

SENSOR
TIP
TIP
Always ensure the product is isolated from the
main Live supply prior to installing/repairing.
Important safety information - read before proceeding further
01
To avoid injury to yourself or the end user, all necessary safety tests as per local codes and regulations
must be carried out prior to, and upon completion of all repairs/installations to AB09/10/11.
Introduction
The instructions contained within this guide must be read carefully before attempting to repair the
AB09/10/11 hand dryer. Failure to accurately follow the instructions may result in the incorrect
operation or repair of the product, damage to property and/or personal injury. Dyson will not be
held liable for any damage to property or personal injury as a result of failure to comply with the
instructions contained herein.
IMPORTANT SAFETY INFORMATION - Read before proceeding further
All electrical installation and repair work should be carried out by a qualified electrician or Dyson
trained Service Engineer in accordance with current local codes or regulations.
Risk of electric shock! If casing is removed or handled improperly the internal components of the unit
may cause harm or become permanently damaged.
BEFORE INSTALLATION
Before beginning any installation work you must confirm the following.
WIRING
• Check that the electrical supply corresponds to that shown on the rating plate. If the unit is
connected to any electrical supply other than stated on the rating plate of the unit, permanent
damage or improper/unsafe operation of the hand dryer may result.
• A means for all-pole disconnection must be incorporated into fixed wiring, in accordance with
national and local wiring regulations.
• When connecting the unit to the electricity supply use cable in accordance with national and local
laws and applicable codes and standards.
• Ensure that the conduit and wires are long enough to connect to the backplate and the terminal
block.
SAFETY
• Isolate the power before installation/repair/service.
INSTALLATION
• Make sure that the unit is installed in compliance with all building codes and/or regulations.
• The unit must be mounted on a flat vertical wall capable of supporting the full weight of the unit.
• Use fixings as specified in this installation guide.
• Ensure no pipe work (gas, water, air) or electrical cables, wires or duct work are located directly
behind the drilling/mounting area.
• Dyson recommends the use of protective clothing, eye ware and materials when installing/
repairing as necessary.
• Do not use sealant when fixing the unit to the wall.
• Do not use any jet wash equipment for cleaning on or near this unit.
• This appliance is intended to be permanently connected to the water mains.
• The water supply to this product must be fitted with a temperature control device in accordance
with local regulations (in the US and Canada must comply with ASSE 1070 so that hot water
delivered from this product is limited to a maximum temperature of 49oC/120oF).

02
Protective safety footware must be worn when installing/repairing AB09/10/11.
LOCATION
• The unit is designed for dry, internal location only.
• Consult local and national accessibility codes and regulations for relevant installation guidelines.
Conformity and compliance is the responsibility of the installer.
• Ensure the required electrical and mixed feed water supplies is available for later connection.
• Water pressure must be: maximum 8 bar (0.8Mpa) and minimum 1 bar (0.1Mpa).
• The sink should not be fitted with a plug.
• When drilling holes, follow the instructions of the manufacturer of the work surface.
Recommended tools to repair AB09/10/11:
1.5mm allen key
Torx T-15 screwdriver
Torx T-10 screwdriver
No. 2 sized Phillips screwdriver
Thin flat bladed screwdriver
Long/needle nosed pliers
Aerator tool
Tap spanner/wrench
1. Insert hands beneath the centre of the tap to
automatically start the mixed water flow. If hands
remain in place the water will continue to flow for
a maximum of 30 seconds before automatically
switching off.
2. Place hands beneath the tap arms to start the
airflow. The water flow will automatically
stop.
3. Draw hands though the airflow. Hands should
be dry within approximately 12 seconds
(14 seconds US and Canada).
The airflow should stop within 4 seconds of hands
being withdrawn from the product.
If hands remain in place the air will
automatically cut off after 30 seconds before
automatically restarting again after 4 seconds.
Testing for correct operation

03
Symptom Solution (in order)Likely fault See section
4 (page 21)
1 (page 05)
2 (page 12)
2 (page 12)
4 (page 21)
2 (page 12)
4 (page 21)
No water, reduced
water flow. Air
working.
1. Ensure mains water
supply to the product
is switched on.
2. Faulty/blocked
Aerator.
3. Faulty Solenoid.
4. Solenoid to PCB
loom assy failure.
5. Comms to PCB
loom assy failure.
6. PCB assy (Tap)
failure.
7. Power supply assy
failure.
8. Water pipe service
assy failure.
•Check Aerator for blockages. Replace
if necessary.
•Check Solenoid functions. Replace if
necessary.
•Check Solenoid to PCB loom assy for
fitting/function. Replace if necessary.
•Check Comms to PCB loom assy for
fitting/function. Replace if necessary.
•Check PCB assy (Tap) for alignment
function. Replace if necessary.
•Check Power supply assy for function.
Replace if necessary.
•Check Water pipe service assy for
blockages. Replace if necessary.
Water on all the
time.
1. Faulty Solenoid.
2. Solenoid to PCB
loom assy failure.
3. PCB assy (Tap)
failure.
4. Lens housing assy
failure.
•Check Solenoid functions. Replace if
necessary.
•Check Solenoid to PCB loom assy for
fitting/function. Replace if necessary.
•Check PCB assy (Tap) for alignment
function. Replace if necessary.
•Check Lens housing assy is clean.
Replace if necessary.
Air on all the time.
No power
(No water/No air).
1. PCB assy (Tap)
failure.
2. Lens housing assy
failure.
1. Fault with mains
power supply to
product.
2. Power supply assy
failure.
•Check PCB assy (Tap) for alignment
function. Replace if necessary.
•Check Lens housing assy is clean.
Replace if necessary.
•Ensure mains power supply to product
is switched on.
•Test to ensure mains power supply to
connector block is present.
•Replace Power supply assy.
1 (page 05)
2 (page 12)
4 (page 21)
4 (page 21)
4 (page 21)
4 (page 21)
2 (page 12)
The following table summarises a number of potential failures, and recommended solutions to resolve
them.

04
Symptom Solution (in order)Likely fault See section
4 (page 21)
2 (page 10)
1 (page 05)
No air/reduced
airflow. Water
working.
Machine switching
on intermittently -
water and air.
or
Cutting out in use.
1. Fault with Air
hose assy.
2. Fault with Motor
bucket assy.
1. PCB assy (Tap)
failure.
2. Lens housing assy
failure.
3. Comms loom
assy failure.
4. Power supply assy
failure.
•Check PCB assy (Tap) for alignment
function. Replace if necessary.
•Check Lens housing assy is clean.
Replace if necessary.
•Ensure Comms loom assy
is adequately attached both ends.
•Test Comms loom assy for resistance
and replace if necessary.
•Check Power supply assy for function.
Replace if necessary.
•Ensure Air hose assy is adequately
sealed onto threaded Tap stem.
•Check Air hose assy for splits and
replace if necessary.
•Replace Motor and Bucket Service assy.
4 (page 21)
4 (page 21)
2 (page 12)&
4 (page 21)
2 (page 12)
2 (page 12)

05
Section 1
Solenoid assembly removal
01 02
03 04
06
05

01 Using a small flat bladed screwdriver, unclip and remove the HEPA filter from the base of the
Motorbucket.
02 In some cases a T-15 screw may have been fitted into the Motorbucket release button. If this is the
case, remove.
03 Press the Motorbucket release button and remove the Motorbucket.
04 Disconnect the mains water supply from the Solenoid assembly.
05 Remove the two T-15 screws in the water cover.
06 Loosen the water pipe clip on the water pipe.
07 Disconnect the Solenoid connector and remove from the Solenoid to PCB loom.
Remove the two Phillips screws.
08 Unclip the Solenoid from the Backplate.
09 Detach the Solenoid from the water pipe.
06
Section 1
Solenoid assembly removal
Warning: before continuing ensure the power and water supplies to the the machine are switched off.
07 08
09

13
11
12
14 15
07
10
Section 1
Solenoid assembly fitting

18
17
16
08

09
10 Push the water pipe as far as possible onto the new Solenoid.
11 Clip the solenoid into the Backplate.
12 Connect the Solenoid to the Solenoid to PCB loom.
13 Locate the water pipe clip onto the end of the water pipe and fasten into place.
Fit the two Phillips screws.
14 Attach the mains water supply to the Solenoid.
15 Turn on the mains water supply. Check that there are no leaks at the Solenoid inlet.
Turn on the power to the product. Insert hands under the centre of the tap to activate the water.
Check that there are no leaks at the Solenoid outlet.
16 Refit the water cover and two screws.
17 Hook the top of the Motorbucket into the backplate. Push the bottom of the Motorbucket into
position in the backplate.
If previously fitted, fit the T-15 screw into the Motorbucket release catch.
18 Clip the HEPA filter assembly into the base of the Motorbucket.
After reassembling the product follow the instructions on page 2 to test the product for adequate
operation.
Section 1
Solenoid assembly fitting
Other manuals for AB09
5
This manual suits for next models
2
Table of contents
Other Dyson Plumbing Product manuals
Popular Plumbing Product manuals by other brands

Weka
Weka 506.2020.00E ASSEMBLY, USER AND MAINTENANCE INSTRUCTIONS

Kohler
Kohler K-6228 Installation and care guide

UBERHAUS DESIGN
UBERHAUS DESIGN 75175017 Operator's manual

American Standard
American Standard DetectLink 6072121 manual

Uponor
Uponor Contec TS Mounting instructions

Pfister
Pfister Selia 49-SL Quick installation guide

Kohler
Kohler Centerset K-15240 Homeowner's guide

Viega
Viega Prevista Dry 8522.33 Instructions for use

Sanela
Sanela Lema SLP 59RB Instructions for use

Elkay
Elkay EDF15AC Installation, care & use manual

Hans Grohe
Hans Grohe AXOR Citterio E 36702000 Instructions for use/assembly instructions

baliv
baliv WT-140 manual