The basic workstation comes with a SCSI connector in base
slot 5 and a ThinWire Ethernet connector in base slot 6 on the
system unit.
You can have option modules in option slots 0, 1, and 2.
Direct memory access priority for the option slots is as follows:
Slot 2—Highest priority. Use this slot to connect hardware
you want to access memory first.
Slot 1—Next highest priority.
Slot 0—Lowest priority.
Set up any expansion boxes.
You can connect up to seven SCSI devices to a SCSI connector
on the system unit so long as the amount of internal and
external cabling does not exceed 19 feet 8 inches in length.
Caution: Using more than 19 feet 8 inches (236 inches) of cable,
including cable inside expansion boxes, to connect devices to a given
SCSI connector on the system unit can make those devices unreliable.
When you stack your storage device expansion boxes, use the
following table to determine how much cable you will be using.
Cable Length
BA42 storage expansion box internal cable 30 inches
TK50Z tape drive internal cable 14 inches
RRD40 optical compact disc drive internal cable 6.5 inches
TLZ04 tape drive internal cable 38 inches
50-pin to 50-pin box-to-box external cable 18 inches
68-pin to 50-pin system-unit-to-expansion-box external
cable 74 inches
3