Casio DT-300 User manual

DT-300
Hardware Manual
(Version 1.00)
CASIO Computer Co., Ltd.
Copyright ©2003. All rights reserved.
September 2003

2
Table of Contents
Editorial Record 3
Preface 4
Chapter 1 Overview 5
1.1 Handheld Operability 5
1.2 Main Hardware Features 5
1.3 Improved Performances 5
1.4 Basic Hardware Specifications 5
1.5 Available Model 6
1.6 Options 6
1.7 Accessories 6
1.8 Cosumables 6
Chapter 2 Appearance 7
2.1 DT-300 7
2.2 DT-364IOE (Bridge Satellite Cradle) 8
Chapter 3 System Configuration 10
3.1 Interface Configuration 10
3.2 Connection 10
Chapter 4 Specifications 11
4.1 DT-300 11
4.2 DT-364IOE 13
4.2.1 LED 15
4.2.2 DIP Switch Setting 16
4.3 Keyboard Layout 17
4.4 Compliance 18
4.4.1 DT-300 18
4.4.2 DT-9020ADP (AC Adaptor) 18
Chapter 5 Electric Specifications 19
5.1 DT-300 19
5.2 DT-364IOE 19
Chapter 6 Environment Specifications 20
6.1 DT-300 20
6.2 DT-364IOE 20
Chapter 7 Durability 21
7.1 DT-300 21
7.2 DT-364IOE 21
Chapter 8 Reliability 22
8.1 DT-300 22
8.2 DT-364IOE 22
Chapter 9 Cable Specifications 23
9.1 Short Lengh 23
9.2 Long Lengh/Chain Connection 24
Chapter 10 Product Identification And Reference Numbers 25
No part of this document may be produced or transmitted in any form or by any means, electronic or
mechanical, for any purpose, without the express written permission of CASIO Computer Co., Ltd. in
Tokyo Japan. Information in this document is subject to change without advance notice. CASIO
Computer Co., Ltd. makes no representations or warranties with respect to the contents or use of this
manual and specifically disclaims any express or implied warranties of merchantability or fitness for
any particular purpose.
© 2003 CASIO Computer Co., Ltd. All rights reserved.

3
Editorial Record
Manual
Version
no.
Date edited Page Content
1.00 September
2003
Original

4
Preface
The DT-300 has been designed and developed to become a basic and low-cost model among the
CASIO handheld data collection terminals. While maintaining software-compatibility with the
DT-900 handheld terminal, the DT-300 has achieved its outstanding features in its class of
conventional handheld data collection terminals including a high screen resolution (112 x 64 dots)
and improved environmental performances.
In this reference manual, the DT-300 is referred to as either “DT-300” or “DT-300M60E” or
Terminal”.

5
1. Overview
1.1 Handheld Operability
Table 1.1
Specification
Dimensions Approx. 140 (D) x 55 (H) x 35 (W) mm
Weight Approx. 170 g
Operating hour 190 (approx.) with AA sized alkaline battery x 2 pcs
1.2 Main Hardware Features
• OS µITRON version 2.0
• Infrared high-speed communication IrDA Ver 1.1 and Casio original infrared communication
• Power supply AA sized alkaline dry cell battery (x 2 pcs)
1.3 Improved Performances
• Optimum display
112 x 64 dots and easy-to-see icons
9 different font types (6x6, 8x8, 10x10, 12x6, 12x12, 16x8, 16x16, 20x10, 20x20 dots)
• High speed scanning
100 times per second
• Ease of key operation
Multi-function keys + scanning trigger key
• Drop proof
Fall from a height of 1.5 m
• Dust and water splash proof
Conforms to IP54 level
1.4 Basic Hardware Specifications
• High-performance CPU
CPU: SH7020 32-bit RISC (4.9152/2.4576/1.2288 MHz)
• Large-capacity memory
Main RAM (D-RAM) ------------------------------------- 2 MB
Executable code + user data storage memory (FROM) - 8 MB

6
1.5 Available Model
Table 1.2
Memory
Model no. RAM FROM Scanner
DT-300M60E 2 MB 8MB Yes (straight emission type)
1.6 Options
Options described in the table are available as dedicated options for DT-300 series.
Table 1.3 List of the options available
Model no. Product Description
DT-364IOE Bridge Satellite Cradle
DT-9020ADP-G AC adaptor 230VAC. For DT-364IOE
DT-9020ADP-U AC adaptor 120VAC. For DT-364IOE
DT-887AX/
DT-887AXA
RS-232C cable Cross cable for DT-364IOE/PC
9-pin female/9-pin female, cable length 1.5m
DT-882RSC RS-232C cable Cross cable for DT-364IOE/PC
9-pin female/25-pin male
DT-883RSC RS-232C cable Cross cable for DT-364IOE/PC
9-pin female/25-pin female
DT-380USB USB cable Cable length 2.0 m
DT-888RSC RS-422 cable Cable for DT-364IOE (connection under daisy-chain),
Cable length 1.0m
1.7 Accessories
Accessories in the table below come in the individual carton box of the terminal.
Table 1.4
Product Q’ty Description
Alkaline battery 2 Operating power for DT-300
Wrist strap 1
User’s guide 1 Multi-language operating guide (English and Chinese)
1.8 Consumables
Table 1.5
Item Specification
AA sized alkaline dry cell battery 2 pcs (LR6) for operating power

7
2. Appearance
2.1 DT-300
Table 2.1
1 Reader port Emits a laser that reads bar codes.
2 Read indicator LED Indicates the status of the read operation; green for a successful read, red for an
unsuccessful read.
3 LCD screen Displays information about the programs being run.
4 Read key Pressing this key activates the bar code reader.
5 Stroke key A total of 18 keys are provided for operations and to turn the power on and off.
6 Reset switch (inside hole) Use a paper clip or other thin object to press the Reset switch located inside the
hole to initialize the internal status of the terminal
7 Wrist strap hook Hook for attaching the wrist strap.
8 Laser warning label Class 2 laser product warning label
9 Buzzer Produces operation confirmation tones. Take care to avoid blocking the buzzer
holes and reducing output sound volume.
10 Main battery compartment Holds the two alkaline batteries.
11 Main battery compartment
lock
Locks the main battery compartment cover in place. The terminal power is
automatically cut off if the cover is removed and the power cannot be turned
back on.
12 Power terminals The terminals receive power from the Bridge Satellite Cradle (DT-364IOE).
13 IrDA port This port is for contact-less infrared data communication with another DT-300
or the Bridge Satellite Cradle (DT-364IOE).
Fig. 2.1

8
2.2 DT-364IOE (Bridge Satellite Cradle)
Table 2.2
No. Name Description
1 USB port This port accepts connection of a USB cable for connection to a computer
for transfer of system data and file data. Use of the USB port requires
installation of a special driver on the PC.
2 RS-232C port This port accepts connection of an RS-232C cable for connection to a
computer for transfer of system data and file data. Use of the RS-232C port
requires installation of a special driver on the PC.
3 RS-422C port This port is used when connecting to another Bridge Satellite Cradle.
4 Terminal detect
switch
This switch detects when the DT-300 is seated correctly on the Cradle.
5 IR port This port transfers data with the DT-300 IR port non-contact data
communication.
6 Power contacts Power is supplied to the DT-300 via these contacts.
7 Power switch Turns the power on and off.
8 AC adaptor jack Connect the AC adaptor here.
This lamp indicates whether the system is operating normally. Regardless
of whether or not an DT-300 is mounted this lamp indicates the system
status and whether or not a communication operation with the system can
be performed.
Off : System is not operating.
9 System status
indicator lamp
(LINE)
Green : System is operating.
<Front>
<Top>
<Right Side> <Back>
<Bottom>
Fig. 2.2

9
This lamp shows that the DT-300 is performing data communication via a
serial interface (RS-232C/RS-422).
Off : No data communication being performed
Green flashing : Data communication in progress
10 Communication
indicator lamp
(DATA)
Red : Problem with a connection between two Cradles
This lamp indicates the power status and the mounting status of the DT-300.
Off : Power off
Green : Power on, DT-300 mounted correctly
11 Power indicator
lamp (POWER)
Red : Power on, DT-300 not mounted
12 DIP switches Use these switches to configure the Cradle as required.

10
3. System Configuration
3.1 Interface
DT-364IOE
DT-9020ADP-G
DT-9020ADP-U HOST(PC)
・USB
・RS-232C
・IrDA
・Power Terminal
A wall outlet
DT-364IOE
・RS-422
DT-300M60E
Fig. 3.1
3.2 Connection
DT-300M60E
Host (PC)
USB
or
RS-232C
IrDA
DT-364IOEDT-364IOE
RS-422
DT-9020ADP-G
DT-9020ADP-U
DT-9020ADP-G
DT-9020ADP-U
Max. 8 terminals
under daisy chain
Max. length of cable 1,000 m when using cable compatible with SK-
UTP 100M3P(Sanyo Industrial)
Fig. 3.2
Table of contents
Other Casio Desktop manuals

Casio
Casio FP-200 User manual

Casio
Casio PB-2000C User manual

Casio
Casio PB-100 User manual

Casio
Casio SF-4300B User manual

Casio
Casio FX-890P User manual

Casio
Casio PB-2000C User manual

Casio
Casio Cassiopeia A-10 Troubleshooting guide

Casio
Casio PA-2400U Troubleshooting guide

Casio
Casio FX-795P User manual

Casio
Casio PB-2000C User manual