Argo AS71CL Manual

TECHNICAL DATA
& SERVICE MANUAL
INDOOR UNIT: AS71CL
AS100CL
AS125CL
SPLIT SYSTEM AIR CONDITIONER
AS125CL
0.8180.547.0 11/2008
Model No. Product Code No.
AS71CL 387006173
387006175
387006174AS100CL

IMPORTANT!
Please read before installation
This air conditioning system meets strict safety and operating
standards.
For the installer or service person, it is important to install or
service the system so that it operates safely and efficiently.
For safe installation and trouble-free operation, you must:
• Carefully read this instruction booklet before beginning.
• Follow each installation or repair step exactly as shown.
• Observe all local, state and national electrical codes.
• Pay close attention to all warning and caution notices given in
this manual.
•The unit must be supplied with a dedicated electrical line.
This symbol refers to a hazard or unsafe practice which can result
in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result
in personal injury or product or property damage.
If necessary, get help
These instructions are all you need for most installation sites and
maintenance conditions.
If you require help for a special problem, contact our sale/service
outlet or your certified dealer for additional instructions.
In case of improper installation
The manufacturer shall in no way be responsible for improper
installation or maintenance service, including failure to follow the
instructions in this document.
SPECIAL PRECAUTIONS
• During installation, connect before the refrigerant system and
then the wiring one; proceed in the reverse orden when removing
the units.
When wiring
ELECTRICAL SHOCK CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH. ONLY QUALIFIED,
EXPERIENCED ELECTRICIANS SHOULD ATTEMPT
TO WIRE THIS SYSTEM.
• Do not supply power to the unit until all wiring and tubing are
completed or reconnected and checked, to ensure the grounding.
• Highly dangerous electrical voltages are used in this system.
Carefully refer to the wiring diagram and these instructions when
wiring.
Improper connections and inadequate grounding can cause
accidental injury and death.
•Ground the unit following local electrical codes.
• The Yellow/Green wire cannot be used for any connection
different from the ground connection.
• Connect all wiring tightly. Loose wiring may cause overheating
at connection points and a possible fire hazard.
• Do not allow wiring to touch the refrigerant tubing, compressor,
or any moving parts of the fan.
• Do not use multi-core cable when wiring the power supply and
control lines. Use separate cables for each type of line.
When transporting
Be careful when picking up and moving the indoor and outdoor
units. Get a partner to help, and bend your knees when lifting to
reduce strain on your back. Sharp edges or thin aluminium fins on
the air conditioner can cut your fingers.
When installing...
• Keep all tubing runs as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the flare
and union tubes before connecting them; screw by hand and
then tighten the nut with a torque wrench for a leak-free
connection.
• Check carefully for leaks before starting the test run.
NOTE:
Depending on the system type, liquid and gas lines may be either
narrow or wide. Therefore, to avoid confusion, the refrigerant
tubing for your particular model is specified as narrow tube for
liquid, wide tube for gas.
When servicing
• Turn the power OFF at the main power board before opening
the unit to check or repair electrical parts and wiring.
• Keep your fingers and clothing away from any moving parts.
• Clean up the site after the work, remembering to check that no
metal scraps or bits of wiring have been left inside the unit being
serviced.
• Ventilate the room during the installation or testing the refrigeration
system; make sure that, after the installation, no gas leaks are
present, because this could produce toxic gas and dangerous
if in contact with flames or heat-sources.
WARNING
CAUTION
WARNING
… In a ceiling
Make sure the ceiling is strong enough to hold the unit-weight.
It may be necessary to build a strong wooden or metal frame to
provide added support.
… In a room
Properly insulate any tubing run inside a room to prevent
"sweating", which can cause dripping and water damage to
walls and floors.
... In moist or uneven locations
Use a raised concrete base to provide a solid level foundation
for the outdoor unit. This prevents damage and abnormal
vibrations.
... In area with strong winds
Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.
... In a snowy area (for heat pump-type systems)
Install the outdoor unit on a raised platform that is higher then
drifting snow. Provide snow vents.
When connecting refrigerant tubing
2

Page
1. SPECIFICATIONS 4
1-1 Unit specifications 4
1-2 Major Component specifications 6
1-3 Other Component specifications 8
2. DIMENSIONAL DATA 9
3. ELECTRICAL DATA 11
3-1 Electric Wiring Diagram 11
3-2 Wiring System Diagrams 11
4. FUNCTION 12
4-1 Cool Mode Operation 12
4-2 Dry Mode Operation 13
4-3 Fan Mode Operation 13
4-4 Auto Fan Speed 13
4-5 Forced Mode 14
4-6 Protection Operations in Cool and Dry Modes 14
4-7 I FEEL Function 15
4-8 NIGHT Function 15
4-9 DRAIN PUMP Mode 15
4-10 Diagnostic 16
4-11 Jumpers Configuration 16
4-12 Contacts for Building Automation 17
4-13 Maintenance 18
5. TROUBLESHOOTING 19
5-1 Check before and after troubleshooting 19
5-2 Circuit Breaker Trips or Fuse Blows 19
5-3 Circuit Breaker in several minutes after turning air conditioner on 19
5-4 Unit and Compressor do not run 20
5-5 Some parts of the Air Conditioner do not operate 21
5-6 Air Conditioner operates, but abnormalities are observed 22
5-7 Poor Cooling 24
5-8 Excessive Cooling 25
5-9 If a Sensor is defective 25
6. CHECKING ELETRICAL COMPONENTS 26
6-1 Measurement of Insulation Resistance 26
6-2 Checking Continuity of Fuse on PCB Ass'y 27
6-3 Checking Motor Capacitor 27
Table of Contents
3

1. SPECIFICATIONS
1-1 Unit Specifications
AS71CL
Power source
V
olta
g
e ratin
g
Performance
Capacity
Air circulation (High/Med./Low) m³/h
Features
Controls/Temperature controls
Control unit
Timer
Fan speed
Airflow direction
Air Filter
Power noise level High/Med./Low dB-A
Refrigerant tubing connections
Refrigerant Narrow tube mm(in.)
tube diameter Wide tube mm(in.)
Refrigerant
Dimensions & Wei
g
ht
Dimensions (include panel) Height mm
Width mm
Depth mm
Package dimensions Unit Height mm
Width mm
Depth mm
Volume m3
Ceiling panel Height mm
Width mm
Depth mm
Volume m3
Weight (include panel) Net kg
Shipping kg
Ceiling panel Net kg
Shipping kg
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Cooling
6,35 (1/4)
R410A
Microprocessor/ I.C. thermostat
3 and Auto
See catalogue with the requested matching
1140/1020/840
8
220 - 240V ~ 50Hz
230 V - 50 Hz
880
0,1
22
26
860
860
0,238
6
110
965
840
965
Wireless remote control unit
ON/OFF 24 hours
320
338
Auto (Remote control)
Washable, easy acces, long life (2500 hr.)
56/54/53
Flare type
15,88 (5/8)
4

AS100CL AS125CL
Power source
V
olta
g
e ratin
g
Performance
Capacity
Air circulation (High/Med./Low) m³/h
Features
Controls/Temperature controls
Control unit
Timer
Fan speed
Airflow direction
Air Filter
Power noise level High/Med./Low dB-A
Refrigerant tubing connections
Refrigerant Narrow tube mm(in.)
tube diameter Wide tube mm(in.)
Refrigerant
Refrigerant control
Dimensions & Wei
g
ht
Dimensions (include panel) Height mm
Width mm
Depth mm
Package dimensions Unit Height mm
Width mm
Depth mm
Volume m3
Ceiling panel Height mm
Width mm
Depth mm
Volume m3
Weight (include panel) Net kg
Shipping kg
Ceiling panel Net kg
Shipping kg
DATA SUBJECT TO CHANGE WITHOUT NOTICE
3 and Auto
ON/OFF 24 hours
Microprocessor/ I.C. thermostat
1920/1680/1320
Wireless remote control unit
220 - 240V ~ 50Hz
230 V - 50 Hz
Cooling
See catalogue with the requested matching
R410A
Capillary tube
860
1150
368
Auto (Remote control)
63/60/56
Flare type
9,52 (3/8)
840
0,35
Washable, easy acces, long life (2500 hr.)
8
110
1250
965
19,05 (3/4)
350
1170
10
0,131
27
32
5

1-2 Major Component Specifications
AS71CL
Controller PCB
Part No.
Controls
Control circuit fuse
Jumper setting JP1..JP5
Remote Control Unit
Fan & Fan Motor
Type
Q'ty ……. Diameter mm
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Running Amps A
Power input W
Coil resistance (Ambient temp. 20 °C )
Ω
BRN-WHT: 170,3
WHT-VLT: 18,1
VLT-ORG: 43,2
ORG-YEL: 43,2
WHT-PNK: 83,5
YEL-BLK: 60,2
Safety devices Type
Operating temp. Open °C
Close °C
Run capacitor µF
VAC
Panel
Model
Flap motor
Type
rating
coil resistance (25°C) k
Ω
Heat Exch. Coil
Coil
Rows
Fin pitch mm
face area m2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
SAC W-REM
400 ± 7%
SAC ON-OFF IDU
Microprocessor
250 V - 3,15 A
2,54mm-5pcs
0,611
31,4
450
130 ± 8
79 ± 15
4,5
Internal thermal protector
Centrifugal fan
SFG6X-41D6P…1
6 … 470
1…. Ø 443
0,343
Aluminium plate fin / Copper tube
1,5
2
DC 12 V
Stepping motor
ASG25SCL
MP24Z2
6

AS100CL AS125CL
Controller PCB
Part No.
Controls
Control circuit fuse
Jumper setting JP1..JP5
Fan & Fan Motor
Type
Q'ty ……. Diameter mm
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Running Amps A
Power input W
Coil resistance (Ambient temp. 20 °C )
Ω
BRN-WHT: 75,1
WHT-VLT: 6,7
VLT-ORG: 20,6
ORG-YEL: 27,4
WHT-PNK: 42,7
YEL-BLK: 58
Safety devices Type
Operating temp. Open °C
Close °C
Run capacitor µF
VAC
Panel
Model
Flap motor
rating
coil resistance (25°C) k
Ω
Heat Exch. Coil
Coil
Rows
Fin pitch mm
face area m2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
1…. Ø 443
400 ± 7%
MP24Z2
DC 12 V
ASG3648SCL
Centrifugal fan
SFG6X-81A6P…1
6 … 530
0,765
38
2
Internal thermal protector
130 ± 8
79 ± 15
6
1,5
0,556
Aluminium plate fin / Copper tube
450
250 V - 3,15 A
2,54mm-5pcs
SAC ON-OFF IDU
Microprocessor
7

1-3 Other Component Specifications
Trasformer
(
TR
)
Rating Primary
Secondary
Thermal cut-off temp. (PTC) (on the board)
Thermistor
(
Coil sensor
)
Resistance k
Ω
Thermistor
(
Room sensor
)
Resistance k
Ω
Drain pump
Model
Rating Voltage
Input
Total head / capacity
Safet
y
float switch
Model
Contact rating
12W
DC 5V - 50W
500 mm / 400 cc/min.
FS-0218-102
C 883 - 120°C
PJV-1434A
230V
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
A040C5026AA
AC 230 V, 50 Hz
13 V - 5VA
8

2. DIMENSIONAL DATA
AS71CL
Units: mm
12
776
225
8
12
X-view
124
124
7
5
6292
232
100
339
221
59
157
182
261
860
500
500
860
2
2
1
221
308 30
48
124
124
1212 100
776
7
34
566 (Suspention bolt pitch)
820 (Ceiling opening)
820 (Ceiling opening)
377
Panel center
757 (Suspention bolt pitch)
368 25
9
X
Air intake grille
Air outlet
Refrigerant liquid line [D. 9.52 (In case of 25 typ
e
,
use the tube connector.)]
Refrigerant gas line
D. 12.7: 9, 12 type
Drain connection
Power supply entry
For discharge duct
For fresh air intake
Suspension bolt mounting
9
6.35
D.1
5
.
88
D.1
5
.
88
9

AS100CL
AS125CL
856 (Suspention bolt pitch)
820 (Ceiling opening)
1110 (Ceiling opening)
522
Panel center
757 (Suspention bolt pitch)
513 25
9
8
83
2
2
1
4
X
X-view
124
124
124
338 30
48
124
1066
12 100
12
1212
244
249
776
180 57
6
244
182
157
59
291
292 339
232
790
1150
860
500
Air intake grille
Air outlet
Refrigerant liquid line (D.9.52)
Refrigerant gas line (D.19.05)
Drain connection
Power supply entr y
For discharge duct
For fresh air intake
Suspension bolt mounting
9
10
This manual suits for next models
2
Table of contents
Other Argo Air Conditioner manuals

Argo
Argo ADS22MH User manual

Argo
Argo Glamour User manual

Argo
Argo AFIAS11DC User manual

Argo
Argo X3I ECO AS45HL Operating manual

Argo
Argo FCW01 Operating manual

Argo
Argo dados 9/13 User manual

Argo
Argo DUAL 14 DCI R32 Operating manual

Argo
Argo ERIS User manual

Argo
Argo AE2MI56AH User manual

Argo
Argo CAFM255R5I Manual
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual