ABB M2131xPx-A series User manual

VER:1.3 │20.06.2017
Operating Instructions
ABB-Welcome
Mini video outdoor station
M2131xPx-A
M2136xPx-A

Table of contents
Operating Instructions VER:1.3 │2
Table of c ontents 1Safety............................................................................................................................................................................3
2Intended use .................................................................................................................................................................3
3Environment..................................................................................................................................................................3
3.1 ABB devices.....................................................................................................................................................3
3.2 Front overview.................................................................................................................................................. 4
3.3 Terminal description......................................................................................................................................... 5
3.4 Lock type and connection ................................................................................................................................ 7
4Technical data...............................................................................................................................................................8
5Mounting/Installation.....................................................................................................................................................9
5.1 Requirement for the electrician........................................................................................................................ 9
5.2 Mounting......................................................................................................................................................... 10
5.2.1 Preparation ..................................................................................................................................................10
5.2.2 Surface mounting.........................................................................................................................................10
5.2.3 Flush mounting ............................................................................................................................................11
5.2.4 Cavity wall installation..................................................................................................................................13
5.2.5 Dismantling..................................................................................................................................................15
5.2.6 Replace the nameplate................................................................................................................................15
5.2.7 Installation situations....................................................................................................................................16
6Commissioning............................................................................................................................................................ 17
6.1 Configure functions of the 1st/2nd pushbutton..............................................................................................17
6.2 Setting general call function...........................................................................................................................19
7Operation .................................................................................................................................................................... 20
7.1 Manage ID cards by mini outdoor station ......................................................................................................20
Notice.................................................................................................................................................................................... 22

Safety
Operating Instructions VER:1.3 │3
1Safety
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or indirect
contact with live components.
This can result in electric shock, burns or even death.
– Disconnect the mains power supply prior to installation and/or disassembly!
– Permit work on the 110-240 V supply system to be performed only by
specialist staff!
2Intended use
The outdoor station is an integral part of the ABB-Welcome door communication system and
operates exclusively with components from this system.
3Environment
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with household
waste.
– The device contains valuable raw materials that can be recycled. Therefore,
dispose of the device at the appropriate collecting facility.
3.1 ABB devices
All packaging materials and devices from ABB bear the markings and test seals for proper
disposal. Always dispose of the packing materials and electric devices and their components via
an authorized collection facility or disposal company.
ABB products meet the legal requirements, in particular the laws governing electronic and
electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006)

Environment
Operating Instructions VER:1.3 │4
3.2 Front overview
Fig. 1
No Function
1Light sensor
2Infrared LED
3Indicator LED (ring, call and door open)
4Speaker and microphone integration
5Pushbutton
6Nameplate
Tab.1
1
23
4
5
6

Environment
Operating Instructions VER:1.3 │5
3.3 Terminal description
Fig. 2
No Function
1Connector for device software update
2Rotary switch to set the address of outdoor station (1-9)
3Set feedback tone of pushbutton ON/OFF
4Set general call to all indoor stations in one family: ON/OFF
If GC=ON, press button 1/button 2, all IS ring
5
Configuration function of 1st/2nd round pushbutton
5A mini video outdoor station with one pushbutton
3 -> OFF; 4 -> OFF = Call IS 001
3 -> ON; 4 -> OFF = Switch on light
3 -> OFF; 4 -> ON = Call guard unit
3 -> ON; 4 -> ON = Call IS 001
5B mini video outdoor station with two pushbuttons
3 -> OFF; 4 -> OFF = Call IS 001/002
3 -> ON; 4 -> OFF = Switch on light/call IS 001
3 -> OFF; 4 -> ON = Call guard unit/call IS 001
3 -> ON; 4 -> ON = Call IS 001/call IS 002
1
2
3
4
5
6
7
8
9
10
11
12
13

Environment
Operating Instructions VER:1.3 │6
6Set the video mode PAL/NTSC
OFF = PAL video mode
ON = NTSC video mode
7
Set default lock
OFF = set (Lock-GND) as default lock
ON = set (COM-NC-NO) as default lock
*Default lock is controlled by "unlock" button on IS
8Plug-in clamps (a,b) for bus connection
9Plug-in clamps (Exit-GND) for exit button
10 Plug-in clamps (Lock-GND) for door opener
11 Plug-in clamps (COM-NC-NO) for floating output, door opener
12 Rotary switch to adjust default door lock release time, 1-10s
13 Rotary switch to adjust loudspeaker volume
Tab.2

Environment
Operating Instructions VER:1.3 │7
3.4 Lock type and connection
Lock type Operation type Voltage Wiring type
Electrical strike lock,
12 V Power on to open 12 VDC/AC Type A
Type B
Electrical strike lock,
24 V Power on to open 24 VDC/AC Type B
Electrical rim lock, 12 V Power on to open 12 VDC Type A
Type B
Electrical mortise lock Power off to open 12 VDC Type C
Magnetic lock Power off to open 12/24 V DC Type C
Tab.3
Fig. 3
a
b
EXIT
GND
LOCK
COM
NO
NC
a
b
EXIT
GND
LOCK
COM
NO
NC
a
b
EXIT
GND
LOCK
COM
NO
NC
PS
TypeA TypeB Type C
+
-
PS
+
-

Technical data
Operating Instructions VER:1.3 │8
4Technical data
Designation Value
Operating temperature -40 °C - +70 °C
Protection IP 54
Power supply, door opener (Lock-GND) 18 V 4 A impulsive, 250 mA holding
Floating supply, door opener (COM-NC-NO) 30 V DC/AC 1A
Single-wire clamps 2 x 0.28 mm2- 2 x 0.75 mm2
Fine-wire clamps 2 x 0.28 mm2- 2 x 0.75 mm2
Bus voltage 20-30 V DC
Tab.4

Mounting/Installation
Operating Instructions VER:1.3 │9
5Mounting/Installation
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or indirect
contact with live components.
This can result in electric shock, burns or even death.
– Disconnect the mains power supply prior to installation and/or disassembly!
– Permit work on the 110-240 V supply system to be performed only by
specialist staff!
5.1 Requirement for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering
knowledge and experience.
– Incorrect installation endangers your life and that of the user of the electrical
system.
– Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation
are as follows:
– Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect
2. Secure against being re-connected
3. Ensure there is no voltage
4. Connect to earth and short-circuit
5. Cover or barricade adjacent live parts.
– Use suitable personal protective clothing.
– Use only suitable tools and measuring devices.
– Check the type of supply network (TN system, IT system, TT system) to
secure the following power supply conditions (classic connection to ground,
protective grounding, necessary additional measures, etc.).

Mounting/Installation
Operating Instructions VER:1.3 │10
5.2 Mounting
5.2.1 Preparation
Use gloves to protect yourself from being cut.
Fig. 4
5.2.2 Surface mounting
Fig. 5
99 mm
26.5 mm
78 mm
1
6
8
m
m
147 mm
①
②
This manual suits for next models
1
Table of contents
Other ABB Security System manuals

ABB
ABB Welcome M21311P1-A Setup guide

ABB
ABB ZMT Zirconia User manual

ABB
ABB L240 Series User manual

ABB
ABB FIM 1300 Series User manual

ABB
ABB SACO 16D1 User manual

ABB
ABB SAS-W1.1E User guide

ABB
ABB 83220 AP-5 series User manual

ABB
ABB Welcome M2303 User manual

ABB
ABB Welcome IP H8131.P. Series User manual

ABB
ABB Arc Guard System TVOC-2 Product manual
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual