5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Certification Exhibit
FCC ID: U4A-YRHCPZB0
IC: 6982A-YRHCPZB0
FCC Rule Part: 15.247
IC Radio Standards Specification: RSS-210
ACS Project Number: 12-0001
Manufacturer: Assa Abloy Inc.
Models: YRDZB, YRD210-ZB, YRD220-ZB, YRT210-ZB, YRT220-ZB
Manual – YRT220-ZB

For Technical Assistance call Yale at 1-800-810-WIRE (9473)
NOTE TO INSTALLER
FAILURE TO FOLLOW THESE INSTRUCTIONS
COULD RESULT IN DAMAGE TO THE PRODUCT
AND VOID THE FACTORY WARRANTY
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com.
Click "Product Information & Documentation" and then "Installation Instructions".
Este documento está disponible en español en nuestra página de internet. Vaya a www.yalerealliving.com.
Presione "Información del Producto y Documentación" y luego "Instrucciones de Instalación".
Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalerealliving.com.
Cliquez sur le "Information sur le produit et Documentation" et puis "Installation Instructions".
Yale Real Living™ Touchscreen Lever
Installation and Programming Instructions

2
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
Warnings .........................................................................................................................2
Return Lock to Factory Default ................................................................................3
Introduction .....................................................................................................................3
Installation
Components and Tools .............................................................................................4
Prepare Lock for Installation ................................................................................. 5-6
Install Lock .......................................................................................................... 6-11
Programming
Programming Features-Menus-Keys-Definitions ............................................. 12-13
Operation .......................................................................................................... 14-16
Miscellaneous Information
Hardware Troubleshooting .....................................................................................17
Programming Troubleshooting ...............................................................................18
Installing the Network Module ...............................................................................19
Sample Pin Code Management Sheets ........................................................... 23-24
TABLE OF CONTENTS
WARNINGS
FCC:
FCC ID: U4A-YRHCPZW0 (Z-Wave); U4A-YRHCPZB0 (Zigbee)
Model(s): YRT220-ZW, YRT220-ZB
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful Interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and
security of this product. Misalignment can cause performance degradation and a lessening of
security.
Finish Care: This lockset is designed to provide the highest standard of product quality and perfor-
mance. Care should be taken to ensure a long-lasting finish. When cleaning is required use a soft, damp
cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes could damage the coat-
ing and result in tarnishing.
Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc.
could void the user's authority to operate the equipment.

3
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
Factory Default Settings
To reset the lock to factory default, see the following:
The following procedure returns the lock to its factory defaults
by deleting all user codes (including the Master PIN code*) and
returning all programming features to their original default settings
(see below).
1. Remove the batteries and then remove the inside escutcheon
to access the reset button.
2. The reset button (see image at right) is located above the
PCB cable connector.
3. Hold down the reset button for a minimum of 3 seconds and
then reinstall the batteries; once the batteries are properly
installed, release the reset button.
All features (including adjustable settings** (see below) should
now be returned to factory default.
Upon reset, Master Code Registration is the only option available
and must be performed prior to any other programming of the lock.
See "Operation" later in this manual for programming instructions.
Reset Lock to Factory Default
Reset Button
Inside Escutcheon
Settings Factory Default
Master Code Registration required
Auto Re-lock Enabled
One Touch Re-Lock Enabled
Audio Enabled
Auto Re-lock Time **30 Seconds
Wrong Code Entry Limit **5 Times
Shutdown Time **60 Seconds
**Adjustable only when using Network Module

4
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
INTRODUCTION
The Yale Real Living™ Stand-alone Touchscreen Deadbolt Lock combines a robust lockset with a
contemporary electronic aesthetic.
Users benefit from an interactive touchscreen that makes day-to-day access effortless, as well as
offering voice-guided programming for simple updates to user information in the event of staffing
changes or security breaches. Yale Real Living™ is engineered for quick and easy installation and
fits in place of a standard deadbolt lock door prep (ANSI/BHMA A156.115).
If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network
controller. That distance is influenced by objects between the lock and the controller and may be
expanded depending on proximity to other RF network devices. Also, if the lock is connected to a
network controller, it is recommended that it is programmed through the centralized user interface
(PC or hand-held device) to ensure communication between the lock and the controller unit.
Industry Canada:
Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)
Model(s): YRT220-ZW, YRT220-ZB
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment
Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne
causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce
dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle
interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies:
“This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm between
the radiator and your body. This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.”
Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication.
En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne
d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour
réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies
de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire
pour une communication réussie.
Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s).
Operation is subject to the following two conditions: 1) this device may not cause interference, and 2)
this device must accept any interference, including interference that may cause undesired operation of
the device.
Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son
fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des
interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent
causer un mauvais fonctionnement du dispositif.

5
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
Lock Installation
#2 Phillips screw driver
Allen wrench (3mm) - provided
Parts Illustrations
Tools Needed
COMPONENTS AND TOOLS
INSTALLATION
4 AA Alkaline
Batteries
Latch bolt
Strike
Door Prep
2-1/8" (54mm) hole saw
1" (26mm) boring bit
7/64" (2.5mm) drill bit
Chisel & hammer
Battery Cover
Network Module
(Optional)
Outside
Escutcheon
Latch
Keys
(4) Inside Escutcheon
Mounting Screws
(Pack 1)
(2) Inside Mounting Plate Screws
(Pack 1)
(2) Latch & (2) Strike Plate Mounting
Screws (Pack 2)
Cylinder
Installation Instructions
Template
Latch Bolt
Strike Plate
Included in the box. . .
Inside Mounting Plate
(with gasket)
Inside Escutcheon
Outside Escutcheon
(2) Screw Packs (see below)
Keys
Cylinder
Battery Cover
Allen Wrench
4 AA Alkaline Batteries
Allen Wrench
(2) Hex Set Screws
(Pack 1)
Inside
Escutcheon
Outside & Inside Lever
Handles
Inside Mounting Plate
with Gasket
(back of Inside Escutcheon)

6
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
INSTALL LOCK
Install Latch
A. Remove the latch (Fig. 1) and strike plate from the packaging.
NOTE: Latch ships with backset in 2-3/8" position (Fig. 1).
Backset is the measurement from door edge to center
of 2-1/8" diameter hole (see template supplied with lock).
If required, pull to extend to 2-3/4" backset position (Detail 1A).
NOTE: Different holes are used for (2) through bolts depending on backset (see Detail 1A).
Figure 1
Detail 1A
2-3/8" through bolt posts
2-3/4" through bolt posts
The lock is packed representative of how it will install on the door.
Before installing the lock on the door:
B. Install latch bolt in door.
1. Attach with two (2) M4 x 25.4mm screws supplied.
C. Install strike on the door frame, using two (2) M4 x 25mm
screws supplied, making sure to allow for the latch to be
centered in the strike.
NOTE: The latch bolt (and strike) can be installed in only one of two ways -
with the bevel (slope) of latch facing out or facing in while standing
outside of the door.
If the door opens in, the bevel will face the outside; if the doors opens out, the
bevel will face in.
The strike plate is installed according to the orientation of the latch bolt. See
Figures 1 & 2 for an example of a RH door that opens in.
NOTE: Make sure door has been prepped according to specifications in template included
with lock.
(4) M4 x 25.4mm
Flat Head
Combination Screws
NOTE: Both latch face and strike plate have adhesive-backed covers to
prevent marring and should be removed upon installation.
Figure 2

7
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
Figure 1A
Outside Escutcheon
(with gasket)
Do not remove clip from Outside Escutcheon shank until correct handing has
been determined and Outside Lever Handle is to be installed.
(See page 9)
Clip
Shank
NOTE: RED marking
indicates "top" of hub
1. From outside of door, position the outside escutcheon by first routing the cable
through 2-1/8" diameter hole and under the latch (Fig. 3A & B), then insert
posts* and tailpiece into the latch.
Square
Drive Tube
is marked
(WHITE) to
indicate
"top"
NOTE: The "tops" of both the square drive tube and the hub (in the shank) are marked to
indicate their orientation for proper installation (Figures A & B).
Shank
NOTE: Cable goes
under latch (Fig. 1A & 1B).
Outside of Door
Figure 1B
Inside of Door "Top" of Drive Tube
(marked WHITE)
Tailpiece
*Posts are inserted in holes according to
backset adjustment. (Refer back to Detail 1A
under "Install Lock")
Install Outside Escutcheon
Figure A Figure B

8
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
2. Remove the inside mounting plate (with gasket) from
the back (door side) of the inside escutcheon (Fig. 2A).
A. Ensure that gasket on
inside mounting plate
is properly fitted (Fig. 2B).
Figure 2B
Figure 2A
Inside Escutcheon & Mounting Plate
(with gasket)
3. Remove the battery cover from the back of the inside escutcheon (Fig. 3) by loosening
the captive Phillips head screw.
Inside of Door
5. Secure both assemblies by inserting (2) M4 x 25mm
pan head machine screws through the mounting
plate and into the slightly extended through posts of
the outside escutcheon (Fig. 4B).
Ensure that outside escutcheon is vertically aligned.
Tighten securely with a #2 Phillips screwdriver.
Do not over-tighten.
4. Holding the outside escutcheon flush to the door,
position the inside mounting plate by routing the
cable/connector through the mounting plate's 1/2"
rectangular hole below center hole (Fig. 4A).
Figure 4A
6. Finish routing the cable and connector through the left
upper slot, then behind center rib as shown in Fig. 4A.
Figure 4B
Through posts here
Screw
Battery Cover
Install Outside Escutcheon
Figure 3

9
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
7. Attach cable assembly to the inside escutcheon printed circuit board (PCB) by lining up
notches on top of cable connector to slots on PCB connector (Fig. 7A & 7B).
Press connector in firmly using thumbs until completely seated (properly seated position
indicated by arrows on PCB as in Fig. 7B).
8. Install and secure inside escutcheon to inside mounting plate using (4) M4 x 8mm
[8-32 x 5/16"] pan head machine screws through the inside escutcheon into the
mounting plate (Fig. 8).
NOTE: Make sure cable does not obstruct path of the mounting screws.
Inside Escutcheon
Reset Button
Figure 7B
Figure 7A
Cable Connector
Figure 8
This manual suits for next models
4
Table of contents
Other Yale Door Lock manuals

Yale
Yale P-DL01 User manual

Yale
Yale GATEMAN YDM 3109 User manual

Yale
Yale Doorman L3 User manual

Yale
Yale Lockmaster AutoEngage Guide

Yale
Yale 4600CL Series User manual

Yale
Yale YDM4109 User manual

Yale
Yale YSSL10 User manual

Yale
Yale Real Living YRL210 Technical specifications

Yale
Yale 724NS User manual

Yale
Yale YRD210 Technical specifications

Yale
Yale Assure Lock 2 Plus User manual

Yale
Yale Code Handle Manual

Yale
Yale T1L Technical specifications

Yale
Yale 7110 User manual

Yale
Yale YDM3109A User manual

Yale
Yale eBOSS E5400LN Series User manual

Yale
Yale YDR4110 User manual

Yale
Yale Helios S User manual

Yale
Yale Keyless Connected User manual

Yale
Yale Doorman User manual