WIKA TR36 User manual

DE
EN
Operating instructions
Betriebsanleitung
Mode d’emploi
Manual de instrucciones
ES
FR
Threaded resistance thermometer, model TR36
Threaded resistance thermometer, model TR36
Widerstandsthermometer zum Einschrauben, Typ TR36
Sonde à résistance à raccord leté, type TR36
Termorresistencia roscada, modelo TR36

2
14331645.02 07/2021 EN/DE/FR/ES
WIKA operating instructions model TR36
DE
EN
FR
ES
Operating instructions model TR36 Page 3 - 30
Betriebsanleitung Typ TR36 Seite 31 - 58
Mode d'emploi type TR36 Page 59 - 86
Manual de instrucciones modelo TR36 Página 87 - 114
© 06/2021 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!

EN
WIKA operating instructions model TR36
14331645.02 07/2021 EN/DE/FR/ES
3
Contents
Contents
Declarations of conformity can be found online at www.wika.com.
1. General information 4
2. Design and function 5
3. Safety 8
4. Transport, packaging and storage 12
5. Commissioning, operation 13
6. Conguration 18
7. Conguration software WIKAsoft-TT 19
8. Connecting the PU-548 programming unit 21
9. Faults 22
10. Maintenance and cleaning 23
11. Dismounting, return and disposal 24
12. Specications 26

EN
14331645.02 07/2021 EN/DE/FR/ES
4WIKA operating instructions model TR36
1. General information
■
The resistance thermometer described in the operating instructions
has been designed and manufactured using state-of-the-art
technology. All components are subject to stringent quality and
environmental criteria during production. Our management systems
are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling
the instrument. Working safely requires that all safety instructions and
work instructions are observed.
■
Observe the relevant local accident prevention regulations and
general safety regulations for the instrument's range of use.
■
Skilled personnel must have carefully read and understood the
operating instructions prior to beginning any work.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: TE 60.36
- Application consultant: Tel.: +49 9372 132-0
1. General information

EN
WIKA operating instructions model TR36
14331645.02 07/2021 EN/DE/FR/ES
5
2. Design and function
2.1 Overview
Angular connector DIN EN 175301-803 form A
Process connection
Probe tube
2.2 Description
The model TR36 resistance thermometer consists of a thermowell/
protection tube with a xed process connection and is screwed directly
into the process.
If the resistance thermometer is to be operated in an additional
protection tube, a spring-loaded compression tting must be used.
They are designed to be resistant to shock and vibration and all electrical
components are protected against splash water.The vibration resistance
conforms to IEC 60751 (8 g, dependent on the instrument version). The
impact resistance of all versions meets the requirements of IEC 60751.
2. Design and function

EN
14331645.02 07/2021 EN/DE/FR/ES
6WIKA operating instructions model TR36
Ensure that mechanical loads on the connector are minimised,
especially in case of increased ambient temperatures or strong vibration
loads.
The electrical connection is made via an angular connector
DIN 175301-803, form A.
2.3 Dimensions in mm
■
Process connection with parallel thread (or without process
connection)
2. Design and function
Angular connector
DIN EN 175301-803
without process
connection
with compression
tting
with neck tube
Legend:
A Insertion length
NNeck tube length (70 mm)
Ød Probe diameter
At a process temperature of > 150 °C [302 °F], a neck tube length N of 70 mm is
necessary.
A
ca. 74 mm
[approx. 2.913 inch]
Ø27mm
[Ø1.062 inch]
SW27
Hex27
ca. 48 mm
[approx. 1.889 inch]
14352572.03
11 mm
[0.433 inch]
N
A
14 mm
[0.551 inch]
A
70 mm
[2.755 inch]
Ø6/8 mm
[Ø0.236/0.314 inch]
Ød ≥ 3mm
≥ [0.118 inch]
Ød ≥ 3mm
≥ [0.118 inch]
Ød ≥6 mm
≥ [0.236 inch]
Ød ≥6 mm
≥ [0.236 inch]
14352572.03

EN
WIKA operating instructions model TR36
14331645.02 07/2021 EN/DE/FR/ES
7
A
Ød
1/4NPT - ca.15mm [0.590 inch]
1/2NPT - ca.20mm [0.787 inch]
Ød>=6mm [0.236 inch]
A65 mm
[2.559 inch]
ca. 74 mm
[2.913 inch]
Ø27 mm
[Ø1.062 inch]
ca. 48 mm
[approx.1.889 inch]
ca. 60 mm
[approx. 2.362 inch]
20 mm
[0.787 inch]
Ød
N
11318708.03
A
Ød
1/4NPT - ca.15mm [0.590 inch]
1/2NPT - ca.20mm [0.787 inch]
Ød>=6mm [0.236 inch]
A65 mm
[2.559 inch]
ca. 74 mm
[2.913 inch]
Ø27 mm
[Ø1.062 inch]
ca. 48 mm
[approx.1.889 inch]
ca. 60 mm
[approx. 2.362 inch]
20 mm
[0.787 inch]
Ød
N
11318708.03
■
Process connection with tapered thread
2. Design and function
Legend:
A Insertion length
NNeck tube length (70 mm)
Ød Probe diameter
At a process temperature of > 150 °C [302 °F], a neck tube length N of 70 mm is
necessary.
11318708.03
2.4 Scope of delivery
Cross-check scope of delivery with delivery note.
Angular connector
DIN EN 175301-803
with compression
tting
with neck tube

EN
14331645.02 07/2021 EN/DE/FR/ES
8WIKA operating instructions model TR36
3. Safety
3.1 Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result
in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in
light injuries or damage to property or the environment, if not
avoided.
DANGER!
... identies hazards caused by electric power. Should the
safety instructions not be observed, there is a risk of serious
or fatal injury.
WARNING!
... indicates a potentially dangerous situation that can result
in burns, caused by hot surfaces or liquids, if not avoided.
Information
... points out useful tips, recommendations and information
for ecient and trouble-free operation.
3.2 Intended use
The model TR36 resistance thermometer is used as universal
thermometer for the measurement of liquid and gaseous media in
the range -50 … +150 °C [-58 ... +302 °F] (without neck tube) and
-50 … +250 °C [-58 ... +482 °F] (with neck tube). It can be used for
pressures up to 140 bar [2,030 psi], 270 bar [3,916 psi] or 400 bar
[5,801 psi] - depending on the protection tube diameters.
3. Safety

EN
WIKA operating instructions model TR36
14331645.02 07/2021 EN/DE/FR/ES
9
The instrument has been designed and built solely for the intended use
described here, and may only be used accordingly.
The technical specications contained in these operating instructions
must be observed. Improper handling or operation of the instrument
outside of its technical specications requires the instrument to be taken
out of service immediately and inspected by an authorised WIKA service
engineer.
The manufacturer shall not be liable for claims of any type based on
operation contrary to the intended use.
3.3 Improper use
WARNING!
Injuries through improper use
Improper use of the instrument can lead to hazardous
situations and injuries.
▶Refrain from unauthorised modications to the instrument.
▶Do not use the instrument within hazardous areas.
▶Do not use the instrument with abrasive or viscous media.
Any use beyond or dierent to the intended use is considered as
improper use.
Do not use this instrument in safety or emergency stop devices.
3.4 Responsibility of the operator
The instrument is used in the industrial sector. The operator is therefore
responsible for legal obligations regarding safety at work.
The safety instructions within these operating instructions, as well as the
safety, accident prevention and environmental protection regulations for
the application area must be maintained.
The operator is obliged to maintain the product label in a legible
condition.
3. Safety

EN
14331645.02 07/2021 EN/DE/FR/ES
10 WIKA operating instructions model TR36
To ensure safe working on the instrument, the operating company must
ensure
■
that suitable rst-aid equipment is available and aid is provided
whenever required.
■
that the operating personnel are regularly instructed in all topics
regarding work safety, rst aid and environmental protection
and know the operating instructions and, in particular, the safety
instructions contained therein.
■
that the instrument is suitable for the particular application in
accordance with its intended use.
■
that personal protective equipment is available.
3.5 Personnel qualication
WARNING!
Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and
damage to property.
▶The activities described in these operating instructions
may only be carried out by skilled personnel who have the
qualications described below.
▶Keep unqualied personnel away from hazardous areas.
Skilled electrical personnel
Skilled electrical personnel are understood to be personnel who,
based on their technical training, know-how and experience as well
as their knowledge of country-specic regulations, current standards
and directives, are capable of carrying out work on electrical systems
and independently recognising and avoiding potential hazards.The
skilled electrical personnel have been specically trained for the work
environment they are working in and know the relevant standards and
regulations.The skilled electrical personnel must comply with current
legal accident prevention regulations.
Special operating conditions require further appropriate knowledge, e.g.
of aggressive media.
3. Safety
Table of contents
Languages:
Other WIKA Thermometer manuals