WIKA CEP1000 User manual

Operating instructions
Betriebsanleitung
Mode d‘emploi
Manual de instrucciones
Manuale d‘uso
GB
D
F
E
I
Precision loop calibrator, model CEP1000
Präziser Stromschleifenkalibrator, Typ CEP1000
Calibrateur de boucle de précision, type CEP1000
Calibrador preciso de bucles de corriente, modelo CEP1000
Calibratore di loop di precisione, modello CEP1000
Precision loop calibrator, model CEP1000

2
11570351.02 10/2010 GB/D/F/E/I
WIKA operating instructions, model CEP1000
GB
D
F
E
I
Operating instructions model CEP1000 Page 3 - 24
Betriebsanleitung Typ CEP1000 Seite 25 - 46
Mode d'emploi type CEP1000 Page 47 - 68
Manual de instrucciones modelo CEP1000
Página 69 - 90
Manuale d'uso modello CEP1000 Pagina 91 - 112
© WIKA Alexander Wiegand SE & Co. KG 2010
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d'emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta posterior!
Prima di iniziare ad utilizzare lo strumento, leggere il manuale d‘uso!
Conservare per future consultazioni!

3WIKA operating instructions, model CEP1000
11570351.02 10/2010 GB/D/F/E/I
GB
Contents
1. General information 4
2. Safety 5
2.1 Intended use 6
2.2 Personnel qualication 6
2.3 Special hazards 7
3. Specications 8
4. Design and function 9
4.1 Short description / Description 9
4.2 Scope of delivery 10
4.3 Front foil of the CEP1000 10
4.4 Battery selection 11
4.5 Input protection 11
5. Transport, packaging and storage 11
5.1 Transport 11
5.2 Packaging 11
5.3 Storage 11
6. Commissioning, operation 12
6.1 First steps 13
6.1.1 Battery saving function 13
6.1.2 HART™ resistance conguration 14
6.2 Basic operating modes 15
6.2.1 Milliampere source 15
6.2.2 Milliampere simulation 16
6.2.3 Milliampere measurement 17
6.2.4 Milliampere measurement with 24 V power supply 17
6.2.5 Voltage measurement 18
6.3 Advanced operating modes 19
6.3.1 Automatic step function/automatic ramp mode 19
6.3.2 Fault percentage function 19
6.3.3 Data acquisition for minimum and maximum 20
7. Maintenance, cleaning and service (recalibration) 21
7.1 Maintenance 21
7.2 Cleaning 21
7.3 Recalibration 21
8. Faults 22
9. Return and disposal 22
9.1 Return 22
9.2 Disposal 23
10. Accessories 23
Contents

4 WIKA operating instructions, model CEP1000
11570351.02 10/2010 GB/D/F/E/I
GB
1. General information
1. General information
■
The loop calibrator described in the operating instructions has been manufactured
using state-of-the-art technology.
All components are subject to stringent quality and environmental criteria during
production. Our management systems are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling the instru-
ment. Working safely requires that all safety instructions and work instructions are
observed.
■
Observe the relevant local accident prevention regulations and general safety regula-
tions for the instrument's range of use.
■
The operating instructions are part of the instrument and must be kept in the immedi-
ate vicinity of the instrument and readily accessible to skilled personnel at any time.
■
Skilled personnel must have carefully read and understood the operating instruc-
tions, prior to beginning any work.
■
The manufacturer's liability is void in the case of any damage caused by using the
product contrary to its intended use, non-compliance with these operating instruc-
tions, assignment of insuciently qualied skilled personnel or unauthorised modi-
cations to the instrument.
■
The general terms and conditions, contained in the sales documentation, shall apply.
■
Subject to technical modications.
■
Factory calibrations/DKD/DAkkS calibrations are carried out in accordance with
international standards.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: CT 81.01
- Application consultant: Tel.: (+49) 9372/132-9986
Fax: (+49) 9372/132-217
E-Mail: [email protected]

5WIKA operating instructions, model CEP1000
11570351.02 10/2010 GB/D/F/E/I
GB
1. General information / 2. Safety
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious
injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light
injuries or damage to equipment or the environment, if not avoided.
Information
... points out useful tips, recommendations and information for ecient
and trouble-free operation.
DANGER!
...identies hazards caused by electric power. Should the safety instruc-
tions not be observed, there is a risk of serious or fatal injury.
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the
appropriate loop calibrator been selected in terms of measuring range,
design and specic measuring conditions.
Non-observance can result in serious injury and/or damage to equip-
ment.
Further important safety instructions can be found in the individual
chapters of these operating instructions.

6WIKA operating instructions, model CEP1000
11570351.02 10/2010 GB/D/F/E/I
GB
2. Safety
2.1 Intended use
The precision loop calibrator CEP1000 is designed for high-accuracy measuring and
simulation of current and voltage.
The instrument has been designed and built solely for the intended use described here,
and may only be used accordingly.
The technical specications contained in these operating instructions must be
observed. Should the instrument be improperly handled or operated outside of its
technical specications, it has to be taken out of service immediately and inspected by
an authorised WIKA service engineer.
Handle electronic precision measuring instruments with the required care (protect from
humidity, impacts, strong magnetic elds, static electricity and extreme temperatures,
do not insert any objects into the instrument or its openings). Plugs and sockets must be
protected from contamination.
If the instrument is transported from a cold into a warm environment, the formation of
condensation may result in the instrument malfunctioning. Before putting it back into
operation, wait for the instrument temperature and the room temperature to equalise.
The manufacturer shall not be liable for claims of any type based on operation contrary
to the intended use.
2.2 Personnel qualication
WARNING!
Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and damage to
equipment.
■
The activities described in these operating instructions may only
be carried out by skilled personnel who have the qualications
described below.
■
Keep unqualied personnel away from hazardous areas.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training,
knowledge of measurement and control technology and on their experience and knowl-
edge of country-specic regulations, current standards and directives, are capable of
carrying out the work described and independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive
media.

7WIKA operating instructions, model CEP1000
11570351.02 10/2010 GB/D/F/E/I
GB
2. Safety
2.3 Special hazards
WARNING!
For hazardous media such as oxygen, acetylene, ammable or toxic
gases or liquids, and refrigeration plants, compressors, etc., in addition
to all standard regulations, the appropriate existing codes or regula-
tions must also be followed.
WARNING!
Protection from electrostatic discharge (ESD) required.
The proper use of grounded work surfaces and personal wrist straps is
required when working with exposed circuitry (printed circuit boards),
in order to prevent static discharge from damaging sensitive electronic
components.
To ensure safe working on the instrument, the operating company must
ensure that the operating personnel are regularly instructed in all topics
regarding work safety, rst aid and environmental protection and knows
the operating instructions and, in particular, the safety instructions
contained therein.
DANGER!
Danger of death caused by electric current!
Operation using a defective power supply unit (e.g. short circuit from
the mains voltage to the output voltage) can result in life-threatening
voltages at the instrument!

8 WIKA operating instructions, model CEP1000
11570351.02 10/2010 GB/D/F/E/I
GB
3. Specications
3. Specications
Specications
Input
Current range 0.000 … 24.000 mA
-25.00 … +125.00 %
Voltage range DC 0.000 … 28.000 V
Input protection Fuseless, up to AC 250 V
Output
Current range 0.000 … 24.000 mA
-25.00 … +125.00 %
Uncertainty ± 0.015 % of reading ± 2 µA
Resolution 1 µA, 1 mV
Drive capability
■
Without HART™-resistor 1200 Ω
■
With HART™-resistor 950 Ω
Loop supply voltage DC 24 V
Range select Decade; incremental to 0.001 mA steps
Special features Auto step/ramp, Auto “%-Error” function, built-in resistor
for HART™ communications
Permissible
■
Operating temperature -10 … +55 °C
■
Storage temperature -20 … +70 °C
Display 5 1/2-digit with character size 9 mm and %-announce-
ment
Range mA, V, %
Recording options MIN-/MAX-storage
Power supply DC 9 V battery
■
Battery life 12 hours (12 mA into 250 Ω continuous)
■
Low battery indicator displayed icon near the end of battery life
EMC / CE conformity 2004/108/EC, EN 61326 Emission (Group 1, Class B) and
Immunity (portable equipment)
Ingress protection IP 52
Calibration 3.1 calibration certicate per DIN EN 10204 (option: DKD/
DAkkS-calibration certicate)
Dimensions 144.7 x 80.0 x 36.3 mm
Weight approx. 340 g
For further specications see WIKA data sheet CT 81.01 and the order documentation.

9WIKA operating instructions, model CEP1000
11570351.02 10/2010 GB/D/F/E/I
GB
3. Specications / 4. Design and function
Dimensions in mm
Side viewFront view
4. Design and function
4.1 Short description / Description
The CEP1000 is a loop calibrator operating in the range of 4 ... 20 mA designed for
both troubleshooting and calibration of circuits without separate power supply.Very
high accuracy and diverse special functions make the instrument to a user-friendly and
highly exible calibration instrument.
The CEP1000 can be used as current reference standard for up to 24 mA, it can also be
used to simulate a 2-wire connection or to perform measurements in circuits with up to
24 mA without separate power supply.
By means of the calibrator it is possible to measure process signal voltages of up to 28 V
direct current with an accuracy of 0.015 % of the measurement value.

10 WIKA operating instructions, model CEP1000
11570351.02 10/2010 GB/D/F/E/I
GB
4. Design and function
1
2
3
4
5
6
7
8
9
10
11
Using the digital knob user interface as well as the decade output control the user
can set both large and incremental changes of the output signal conveniently. Multiple
unique functions such as the automatic step/ramp function allow easy application of the
CEP1000.
Besides the CEP1000 can supply a 2-wire transmitters with voltage and at the same
time measure the emerging current. All measurements are displayed in mA as well as in
percent of the measuring range.
4.2 Scope of delivery
■
Precision loop calibrator model CEP1000
■
Operating instructions
■
Neoprene case
■
Calibration certicate 3.1 per to DIN EN 10204
■
9 V battery
Cross-check scope of delivery with delivery note.
4.3 Front foil of the CEP1000
1) Mode indication
2) Step / ramp indication
3) On/O
4) Current loop key: Activation of
the 24 V power supply in the mA
measuring mode
5) %Error key: indicates the actual
vs. ideal error in %
6) Digital „knob“: output control
7) Simultaneous % display: 4 mA =
0.00 %, 20 mA = 100.00 %
8) Mode key
9) Auto key: Switching between
automatic step and ramp function
(slow or fast)
10) 25 %-key: manual activation of the
step function 4, 8, 12, 16, 20 mA
11) Cursor keys: arrow keys to select
the required decades
Figure 1
Table of contents
Languages:
Other WIKA Test Equipment manuals

WIKA
WIKA DELTA-comb DPGS40TA User manual

WIKA
WIKA CEP6500 User manual

WIKA
WIKA CPB3800 User manual

WIKA
WIKA CTD9100 series User manual

WIKA
WIKA CEP6100 User manual

WIKA
WIKA Wally Box III User manual

WIKA
WIKA PG28 User manual

WIKA
WIKA CTD9100-ZERO User manual

WIKA
WIKA CalibratorUnit CPU6000 Series User manual

WIKA
WIKA CalibratorUnit CPU6000 Series User manual