WIKA D-20-9 User manual

Operating instructions
Betriebsanleitung
Mode d'emploi
Manual de instrucciones
EN
DE
FR
ES
Drucksensor CANopen, Typen D-20-9 und D-21-9
Model D-20-9 Model D-21-9
Pressure sensor CANopen, models D-20-9 and D-21-9
Capteur de pression CANopen, Typen D-20-9 und D-21-9
Sensor de presión CANopen, Typen D-20-9 und D-21-9

2WIKA operating instructions pressure sensor, model D-20-9, D-21-9
EN
DE
2059064.05 EN/DE/FR/ES 01/2019
FR
ES
© 2006 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!
Betriebsanleitung, Typen D-20-9 und D-21-9 Seite 25 - 46
Operating instructions, models D-20-9 and D-21-9 Page 3 - 24
Mode d‘emploi, Types D-20-9 e D-21-9 Page 47 - 68
Manual de instrucciones, modelos D-20-9 y D-21-9 Página 69 - 91

3WIKA operating instructions, pressure sensor, models D-20-9, D-21-9
EN
2059064.05 EN/DE/FR/ES 01/2019
Contents
Declarations of conformity can be found online at www.wika.com
Contents
1. General information 4
2. Design and function 5
3. Safety 6
4. Transport, packaging and storage 9
5. Commissioning, operation 9
6. Faults 14
7. Maintenance and cleaning 17
8. Dismounting, return and disposal 17
9. Specications 19

4WIKA operating instructions, pressure sensor, models D-20-9, D-21-9
EN
2059064.05 EN/DE/FR/ES 01/2019
1. General information
1. General information
■
The instrument described in the operating instructions has been designed and manufactured using state-of-the-
art technology. All components are subject to stringent quality and environmental criteria during production. Our
management systems are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling the instrument.Working safely requires that
all safety instructions and work instructions are observed.
■
Observe the relevant local accident prevention regulations and general safety regulations for the instrument’s range
of use.
■
The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and
readily accessible to skilled personnel at any time. Pass the operating instructions on to the next operator or owner
of the instrument.
■
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work.
■
The manufacturer's liability is void in the case of any damage caused by using the product contrary to its intended
use, non-compliance with these operating instructions, assignment of insuciently qualied skilled personnel or
unauthorised modications to the instrument.
■
The general terms and conditions contained in the sales documentation shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: PE 81.39
- Application consultant: Tel.: +49 9372 132-0
Fax: +49 9372 132-406
info@wika.de

5WIKA operating instructions, pressure sensor, models D-20-9, D-21-9
EN
2059064.05 EN/DE/FR/ES 01/2019
2. Design and function
2. Design and function
2.1 Overview
Electrical connection (depending on version)
Case; product label
Process connection, spanner ats
Process connection, thread (depending on version)
Model D-20-9:
Process connection with pressure port
Model D-21-9:
Process connection with ush diaphragm for highly viscous or crystalli-
sing media that may clog the process connections with pressure port.
2.2 Scope of delivery
■
Pressure sensor
■
Protection cap for process connection
■
Operating instructions
Cross-check scope of delivery with delivery note.

6WIKA operating instructions, pressure sensor, models D-20-9, D-21-9
EN
2059064.05 EN/DE/FR/ES 01/2019
3. Safety
3. Safety
3.1 Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to property or the
environment, if not avoided.
Information
... points out useful tips, recommendations and information for ecient and trouble-free operation.
3.2 Intended use
The pressure sensor is used for measuring pressure. The measured pressure is output as an electrical signal.
This is class B equipment for emissions and is intended for use in industrial environments. In other environments,
e.g. residential or commercial installations, it can interfere with other equipment under certain conditions. In such
circumstances the operator is expected to take the appropriate measures.
Only use the pressure sensor in applications that lie within its technical performance limits (e.g. max. ambient
temperature, material compatibility, ...).
→ For performance limits see chapter 9 “Specications”.
The instrument has been designed and built solely for the intended use described here, and may only be used
accordingly.
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.

7WIKA operating instructions, pressure sensor, models D-20-9, D-21-9
EN
2059064.05 EN/DE/FR/ES 01/2019
3. Safety
3.3 Improper use
WARNING!
Injuries through improper use
Improper use of the instrument can lead to hazardous situations and injuries.
▶
Refrain from unauthorised modifications to the instrument.
▶
Do not use the instrument within hazardous areas.
▶
Do not use the model D-20-9 with abrasive or viscous media.
Any use beyond or dierent to the intended use is considered as improper use.
Do not use this instrument in safety or emergency stop devices.
3.4 Special hazards
WARNING!
For hazardous media such as oxygen, acetylene, ammable or toxic gases or liquids, and refrigeration
plants, compressors, etc., in addition to all standard regulations, the appropriate existing codes or
regulations must also be followed.
WARNING!
Residual media in dismounted pressure transmitters can result in a risk to persons, the environment and
equipment.
Take sucient precautionary measures.
3.5 Personnelqualication
Skilled personnel
Skilled personnel, authorised by the operator, are understood to be personnel who, based on their technical training,
knowledge of measurement and control technology and on their experience and knowledge of country-specic regula-
tions, current standards and directives, are capable of carrying out the work described and independently recognising
potential hazards.

8WIKA operating instructions, pressure sensor, models D-20-9, D-21-9
EN
2059064.05 EN/DE/FR/ES 01/2019
3. Safety
3.6 Labelling, safety marks
Product label
Model code Measuring range
P# Article no. Model designation
S# Serial no. Pin assignment
Power supply Coded date of manufacture
Output signal
Before mounting and commissioning the instrument, ensure you read the operating instructions!
DC voltage
Transmitter
WIKA Alexander Wiegand SE & Co.KG 63911 Klingenberg Germany
S#
P#

9WIKA operating instructions, pressure sensor, models D-20-9, D-21-9
EN
2059064.05 EN/DE/FR/ES 01/2019
4. Transport, packaging and storage / 5. Commissioning, operation
4. Transport, packaging and storage
4.1 Transport
Check the pressure sensor for any damage that may have been caused by transport.
Obvious damage must be reported immediately.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending for
repair).
In order to protect the diaphragm, provide the process connection of the model D-21-9 with the supplied protection cap.
Permissible conditions at the place of storage:
■
Storage temperature: -40 ... +100 °C
■
Humidity: 45 ... 75 % relative humidity (no condensation)
5. Commissioning, operation
5.1 Mechanical mounting
Only use the pressure sensor if it is in perfect condition with respect to safety.
Prior to commissioning, the pressure sensor must be subjected to a visual inspection.
■
Leaking uid is indicative of damage.
■
The diaphragm at the process connection of the model D-21-9 is a safety-relevant component and must not be
damaged.
Requirements for mounting point
The mounting point must meet the following conditions:
■
Sealing faces are clean and undamaged.
■
Sucient space for a safe electrical installation.
■
For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com.
■
Permissible ambient and medium temperatures remain within the performance limits. Consider possible restrictions
on the ambient temperature range caused by mating connector used.
→ For performance limits see chapter 9 “Specications”

10 WIKA operating instructions, pressure sensor, models D-20-9, D-21-9
EN
2059064.05 EN/DE/FR/ES 01/2019
5. Commissioning, operation
Sealing variants
The max. torque depends on the mounting point (e.g. material and shape). If you have any questions,
please contact our application consultant.
→ For contact details see chapter 1 “General information” or the back page of the operating instructions.
1. Seal the sealing face (→ see “Sealing variants”).
2
.
At the mounting point, screw the pressure sensor in hand-tight.
3
.
Tighten with a torque spanner using the spanner ats.
5.2 Electrical mounting
Requirements for voltage supply
→ For power supply see product label
The power supply for the pressure sensor must be made via an energy-limited electric circuit in accordance with
section 9.4 of UL/EN/IEC 61010-1 or an LPS to UL/EN/IEC 60950-1 or class 2 in accordance with UL1310/UL1585
(NEC or CEC).
Parallel threads
Seal the sealing face with flat gasket, lens-type
sealing ring or WIKA profile sealing.
per EN 837 per DIN 3852-E
Tapered threads
Wrap threads with sealing material
(e.g. PTFE tape).
NPT, R and PT
Other manuals for D-20-9
1
This manual suits for next models
1
Table of contents
Languages:
Other WIKA Accessories manuals

WIKA
WIKA LF-1 User manual

WIKA
WIKA CPT62I0 User manual

WIKA
WIKA GD-20 Series User manual

WIKA
WIKA MH-4-CAN Operator's manual

WIKA
WIKA air2guide A2G-85 User manual

WIKA
WIKA MH-4-CAN User manual

WIKA
WIKA SENSeOR AMS01 User manual

WIKA
WIKA P-30 User manual

WIKA
WIKA TR31-3 User manual

WIKA
WIKA FLR Series User manual