ETC310-FS, ETC319-FS, EVC310-FS, EVC319-FS:
No minimum distance.
3
Installation
The product must be installed and maintained by a
suitably qualified person in compliance with the latest
applicable regulations and relevant legislation.
Ensure the luminaire frame and lens are clear of dirt
and debris.
Claims based on defects attributable to improper
installation, application, operation and/or any modifi-
cation carried out by the purchaser or third parties,
and the consequences thereof, are excluded.
Installation Methods
Attention: The luminaire is factory-sealed and does
not need to be opened during installation.
For proper installation, use the supplied installation
blockout.
Ensure that proper drainage is provided for the shown
installation methods:
In landscape areas, sand with gravel base (Fig. I).
In paved areas, concrete with gravel base (Fig. II).
Fig. II
Fig. I
Phase One
Blockout Installation Procedure
(during earth or masonry work)
1) Ensure a suitable recess is provided to accommo-
date installation blockout/mounting ring assembly
B/M.
2) Set installation blockout/mounting ring assembly
B/M in position and ensure that:
a) Arrow Ron mounting ring Mis pointed towards
the object to be illuminated (wall, tree, column).
b) Mounting ring Mis flush with surface F. If the
floor will be tiled or paved afterwards, leave an
appropriate gap.
c) Mains supply cable(s) Ois of sufficient length to
connect sealable junction box Jwith cable Efrom
luminaire.
3) During ongoing earth and/or masonry works, do
not remove stickers on fixing thread holes D.
Ensure that installation blockout/mounting ring
assembly B/M is not damaged and has maintained
its original shape.
Minimum Distance