Vega VEGAPULS WL 61 User manual

Quick setup guide
Radar sensor for continuous level
measurement of water and wastewater
VEGAPULS WL 61
Foundation Fieldbus
Document ID: 47097

2
Contents
VEGAPULS WL 61 • Foundation Fieldbus
47097-EN-170126
Contents
1 For your safety
1.1 Authorised personnel ....................................................................................................... 3
1.2 Appropriate use................................................................................................................ 3
1.3 Warning about incorrect use............................................................................................. 3
1.4 General safety instructions............................................................................................... 3
1.5 EU conformity................................................................................................................... 4
1.6 NAMUR recommendations .............................................................................................. 4
1.7 Radio licenses for Europe ................................................................................................ 4
1.8 Restrictions for the USA and Canada............................................................................... 5
1.9 Radio license for USA/Canada......................................................................................... 5
1.10 Environmental instructions ............................................................................................... 6
2 Product description
2.1 Conguration.................................................................................................................... 7
2.2 Adjustment ....................................................................................................................... 8
3 Mounting
3.1 Mounting versions.......................................................................................................... 10
3.2 Mounting preparations, mounting strap.......................................................................... 13
4 Connecting to power supply
4.1 Wiring plan - version IP 66/IP 68, 2 bar........................................................................... 14
5 Setup with smartphone/tablet (Bluetooth)
5.1 Connecting..................................................................................................................... 15
5.2 Sensor parameter adjustment........................................................................................ 16
5.3 Adjustment ..................................................................................................................... 16
6 Set up with other systems
6.1 DD adjustment programs ............................................................................................... 18
6.2 Field Communicator 375, 475 ........................................................................................ 18
7 Supplement
7.1 Technical data ................................................................................................................ 19
Information:
This quick setup guide enables quick setup and commissioning of
your instrument.
Youcanndsupplementaryinformationinthecorresponding,more
detailed Operating Instructions Manual as well as the Safety Manual
thatcomeswithinstrumentswithSILqualication.Thesemanualsare
available in the download area of "www.vega.com".
Operating instructions VEGAPULS WL 61 - Foundation Field-
bus: Document-ID 38063
Editing status of the quick setup guide: 2017-01-24

3
1 For your safety
VEGAPULS WL 61 • Foundation Fieldbus
47097-EN-170126
1 For your safety
1.1 Authorised personnel
All operations described in this operating instructions manual must
be carried out only by trained specialist personnel authorised by the
plant operator.
During work on and with the device the required personal protective
equipment must always be worn.
1.2 Appropriate use
VEGAPULS WL 61 is a sensor for continuous level measurement.
Youcannddetailedinformationabouttheareaofapplicationin
chapter "Product description".
Operational reliability is ensured only if the instrument is properly
usedaccordingtothespecicationsintheoperatinginstructions
manual as well as possible supplementary instructions.
1.3 Warning about incorrect use
Inappropriate or incorrect use of the instrument can give rise to
application-specichazards,e.g.vesseloverllordamagetosystem
components through incorrect mounting or adjustment. Also the pro-
tectivecharacteristicsoftheinstrumentcanbeinuenced.
1.4 General safety instructions
This is a state-of-the-art instrument complying with all prevailing
regulations and guidelines. The instrument must only be operated in a
technicallyawlessandreliablecondition.Theoperatorisresponsible
for the trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the
compliance of the necessary occupational safety measures with the
current valid rules and regulations and also take note of new regula-
tions.
The safety instructions in this operating instructions manual, the na-
tional installation standards as well as the valid safety regulations and
accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbi-
traryconversionsormodicationsareexplicitlyforbidden.
The safety approval markings and safety tips on the device must also
be observed.
Depending on the instrument version, the emitting frequencies are in
the C, K or W band range. The low emitting frequencies are far below
the internationally approved limit values. When used correctly, the
device poses no danger to health.

4
1 For your safety
VEGAPULS WL 61 • Foundation Fieldbus
47097-EN-170126
1.5 EU conformity
ThedevicefullsthelegalrequirementsoftheapplicableEUguide-
lines.ByaxingtheCEmarking,weconrmtheconformityofthe
instrument with these guidelines.
YoucanndtheEUconformitydeclarationonourwebsiteunder
www.vega.com/downloads.
1.6 NAMUR recommendations
NAMUR is the automation technology user association in the process
industry in Germany.The published NAMUR recommendations are
acceptedasthestandardineldinstrumentation.
ThedevicefullstherequirementsofthefollowingNAMURrecom-
mendations:
• NE 43 – Signal level for fault information from measuring transduc-
ers
• NE53–Compatibilityofelddevicesanddisplay/adjustment
components
• NE107-Self-monitoringanddiagnosisofelddevices
For further information see www.namur.de.
1.7 Radio licenses for Europe
VEGAPULS WL 61
The instrument was tested according to the latest issues of the har-
monizedstandards:
• EN 302372 - Tank Level Probing Radar
• EN 302729 - Level Probing Radar
It is hence approved for use inside and outside closed vessels in
countries of the EU.
Use is also approved in EFTA countries, provided these standards
have been implemented.
For operation inside of closed vessels, the following conditions must
befullled:
• The instrument must be permanently mounted on a closed vessel
made of metal, reinforced concrete, or comparable attenuating
materials
• Flanges,processttingsandmountingaccessoriesmustensure
the microwave impermeability of the vessel and not let the radar
signal escape to the outside
• Ifnecessary,existingviewingwindowsinthevesselmustbe
coated with a microwave impermeable material (e.g. electrically
conductive coating)
• Manholesandangesonthevesselmustbeclosedandsealedto
avoid penetration of the radar signal
• The instrument should be preferably mounted on top of the vessel
with antenna orientation downward
• The instrument must only be installed and maintained by appropri-
atelyqualiedsta

5
1 For your safety
VEGAPULS WL 61 • Foundation Fieldbus
47097-EN-170126
For operation outside of closed vessels, the following conditions must
befullled:
• Theinstallationmustbecarriedoutbytrainedqualiedpersonnel
• The instrument must be stationary mounted and the antenna
directed vertically downward
• The mounting location must be at least 4 km away from radio
astronomy stations, unless special permission was granted by the
responsible national approval authority
• When installed within 4 to 40 km of a radio astronomy station,
the instrument must not be mounted higher than 15 m above the
ground.
Youcanndalistoftherespectiveradioastronomystationsinchap-
ter "Supplement".
Bluetooth radio module
The radio module used in the instrument for wireless Bluetooth com-
munication was tested by the manufacturer according to the latest
edition of the following standard:
• EN 300328 – Wideband transmission systems
It is hence for use inside closed vessels in countries of the EU and
EFTA.
1.8 Restrictions for the USA and Canada
The VEGAPULS WL 61 with wireless Bluetooth communication must
neitherbeoperatedintheUSAorCanadanorimportedorexported.
1.9 Radio license for USA/Canada
This approval is only valid for USA and Canada. Hence the following
textsareonlyavailableinEnglish/Frenchlanguage.
The instrument is in conformity with part 15 of the FCC regulations.
Operation is subject to the following two conditions:
• this device may not cause harmful interference, and
• this device must accept any interference received, including inter-
ference that may cause undesired operation.
• the antenna must be directed vertically downward
FCCrequirementslimitthisdevicetobeusedonlyinaxedinstal-
lation, never in a portable installation or in installations that are in
motion (i.e. cement trucks, etc.).
Changesormodicationsnotexpresslyapprovedbythemanufac-
turer could void the user’s authority to operate the equipment.
ThisdevicecomplieswithIndustryCanadalicense-exemptRSS
standard(s). Operation is subject to the following two conditions:
• this device may not cause interference, and
• this device must accept any interference, including interference
that may cause undesired operation of the device

6
1 For your safety
VEGAPULS WL 61 • Foundation Fieldbus
47097-EN-170126
LeprésentappareilestconformeauxCNRd'IndustrieCanadaap-
plicablesauxappareilsradioexemptsdelicence.L'exploitationest
autoriséeauxdeuxconditionssuivantes:
• l'appareilnedoitpasproduiredebrouillage,et
• l'utilisateurdel'appareildoitacceptertoutbrouillageradioélect-
riquesubi,mêmesilebrouillageestsusceptibled'encompromet-
tre le fonctionnement
1.10 Environmental instructions
Protection of the environment is one of our most important duties.
That is why we have introduced an environment management system
with the goal of continuously improving company environmental pro-
tection.Theenvironmentmanagementsystemiscertiedaccording
to DIN EN ISO 14001.
Pleasehelpusfullthisobligationbyobservingtheenvironmental
instructions in this manual:
• Chapter "Packaging, transport and storage"
• Chapter "Disposal"

7
2 Product description
VEGAPULS WL 61 • Foundation Fieldbus
47097-EN-170126
2 Product description
2.1 Conguration
Youcanndthetypelabelonthesensorhousingaswellasonthe
type label support on the connection cable.
Itcontainsthemostimportantdataforidenticationanduseofthe
instrument.
2
1
15
16
13
14
12
11
5
3
6
4
7
8
10
9
Fig. 1: Layout of the type label (example)
1 Instrument type
2 Product code
3 Approvals
4 Power supply and signal output, electronics
5 Protection rating
6 Measuring range
7 Process and ambient temperature, process pressure
8 Material, wetted parts
9 Hardware and software version
10 Order number
11 Serial number of the instrument
12 Data matrix code for smartphone app
13 Symbol of the device protection class
14 ID number, instrument documentation
15 Reminder to observe the instrument documentation
16 Symbol for Bluetooth
The 4-digit PIN is necessary for the Bluetooth connection to the sen-
sor.The PIN is unique and is only valid of this sensor.
YoucanndthePINasalabelonasupplementarysheetinthesen-
sorpackagingandnexttothetypelabel.
Fig. 2: Bluetooth PIN
Type label
Sensor PIN

8
2 Product description
VEGAPULS WL 61 • Foundation Fieldbus
47097-EN-170126
The type label contains the serial number of the instrument. With it
youcanndthefollowinginstrumentdataonourhomepage:
• Product code (HTML)
• Delivery date (HTML)
• Order-specicinstrumentfeatures(HTML)
• Operating instructions and quick setup guide at the time of ship-
ment (PDF)
• Order-specicsensordataforanelectronicsexchange(XML)
• Testcerticate(PDF)-optional
Go to "www.vega.com", "VEGA Tools" and "Instrument search". Enter
the serial number.
Alternatively, you can access the data via your smartphone:
• Download the smartphone app "VEGA Tools" from the "Apple App
Store" or the "Google Play Store"
• ScantheDataMatrixcodeonthetypelabeloftheinstrumentor
• Enter the serial number manually in the app
2.2 Adjustment
Adjustment via the signal cable
As a standard feature, VEGAPULS WL 61 allows an adjustment via:
• DD adjustment programs
• Field Communicator 375, 475
Wireless adjustment
VEGAPULS WL 61 with integrated Bluetooth module enables the
wireless adjustment via standard adjustment instruments:
• Smartphone/tablet (iOS or Android operating system)
• PC/notebook with Bluetooth USB adapter (Windows operating
system)
Serial number - Instru-
ment search

9
2 Product description
VEGAPULS WL 61 • Foundation Fieldbus
47097-EN-170126
1
4
2
3
Fig. 3: Wireless connection to standard operating devices
1 Display and adjustment module
2 Sensor
3 Smartphone/Tablet
4 Bluetooth USB adapter
5 PC/Notebook

10
3 Mounting
VEGAPULS WL 61 • Foundation Fieldbus
47097-EN-170126
3 Mounting
3.1 Mounting versions
Most simply mount the instrument via the straining clamp. For this
purpose, the connection cable is provided with a strain relief wire of
Kevlar.
In order to avoid faulty measured values, make sure that the sensor
does not oscillate.
> 200 mm
(7.87")
Fig. 4: Mounting via a straining clamp
For a rigid mounting, a mounting bracket with opening for thread
G1½, e.g. from the VEGA product range, is recommended. The
mounting of the sensor in the bracket is carried out via a G1½ counter
nut of plastic.Take note of chapter "Mounting instructions" for the
distance to the wall.
Straining clamp
Mounting bracket
Other manuals for VEGAPULS WL 61
10
Table of contents
Other Vega Accessories manuals

Vega
Vega VEGAPULS 62 User manual

Vega
Vega VEGAPULS 69 User manual

Vega
Vega VEGASON 61 User manual

Vega
Vega VEGAFLEX 86 User manual

Vega
Vega VEGAPULS 69 User manual

Vega
Vega VEGABAR 28 User manual

Vega
Vega VEGABAR 65 User manual

Vega
Vega VEGASON 61 User manual

Vega
Vega VEGAFLEX 82 User manual

Vega
Vega VEGAPULS WL 61 User manual

Vega
Vega VEGAFLEX 86 User manual

Vega
Vega VEGAFLEX 65 User manual

Vega
Vega SMART-SS0102 User manual

Vega
Vega vegaflex 83 User manual

Vega
Vega VEGAPULS 61 User manual

Vega
Vega VEGAFLEX 81 User manual

Vega
Vega VEGAPULS 69 User manual

Vega
Vega FIBERTRAC 31 User manual

Vega
Vega VEGABAR 29 User manual

Vega
Vega VEGAPULS C 22 User manual