Turbotech A91030159 User manual

Non-Contact Infrared Thermometers
Operating Manual
3p
06/08-62B

2

3
TABLE OF CONTENTS
INTRODUCTION………………………………………4
FEATURES……………………………………………4
WIDER ANGE APPLICATION ……………………..….5
SAFETY……………………………………………….5
DISTANCE&SPOTSIZE………………………………..6
SPECIFICATIONS……………………………………..6
FRONT PANEL DESCRIPTION………………..………8
INDICATOR……………………………………………8
BUTTONS……………………………………………..9
MEASURMENT OPERATION……………..…………..11
BATTER YREPLACEMENT……..…………………….13
NOTES………………………………………………. 14
MAINTENANCE ………………………………………17

4
INTRODUCTION
Thank you for purchase of the IR Thermometer. This is
capable of non-contact(infrared) temperature measurements
at the touch of a button. The built-in laser pointer increases
target accuracy while the backlight LCD and handy
push-buttons combine for convenient, ergonomic operation.
The Non-contact Infrared Thermometers can be used to
measure the temperature of objects’ surface that is improper
to be measured by traditional (contact) thermometer (such
as moving object, the surface with electricity current or the
objects which are uneasy to be touched.)
Proper use and care of this meter will provide years of
reliable service.
FEATURES:
Rapid detection function
Precise non-contact measurements
Dual laser sighting
Unique flat surface, modern housing design
Automatic Data Hold
°C/°F switch
Emissivity Digitally adjustable from 0.10 to 1.0
MAX temperature displays

5
Backlight LCD display
Automatic selection range and Display Resolution
0.1ºC(0.1ºF)
Trigger lock
Set high and low alarms
WIDE RANGE APPLICATION:
Food preparation, Safety and Fire inspectors, Plastic
molding, Asphalt, Marine and Screen printing, measure ink
and Dryer temperature, HVAC/R, Diesel and Fleet
maintenance.
SAFETY
Use extreme caution when the laser beam is turned on.
Do not let the beam enter your eye, another person’s
eye or the eye of an animal.
Be careful no to let the beam on a reflective surface
strike your eye.
Do not allow the laser light beam impinge on any gas
which can explode.

6
Distance & Spot Size
As the distance (D) from the object increases, the spot size
(S) of the area measured by the unit becomes larger. The
relationship between distance and spot size for each unit is
listed below. The focal point for each unit is 914mm (36”).
The spot sizes indicate 90% encircled energy.
D:S= 12:1
D
S
12in.
1in @
6in.
0.5in @
25mm @300mm
150mm
12.5mm @
1. SPECIFICATIONS
Temperature range D: S
-50 to 650 °C(-58°F ~ 1202°F) 12:1
Display resolution 0.1 °C(0.1°F) <1000
1°F >1000
Accuracy for targets:

7
Assumes ambient operating temperature of 23 to 25°C(73 to
77°F)
-50 ~ 20°C (-58°F ~ 68°F) ±2.5°C (4.5°F)
20°C ~300°C (68°F ~572°F) ±1.0% ±1.0°C (1.8°F)
300°C ~650°C (572°F ~ 1202°F) ±1.5%
Repeatability
-50~20°C (-58~68°F) : ±1.3°C (2.3°F)
20~650°C (68~1202°F): ±0.5% or ±0.5°C (0.9°F)
Response time 150ms
Spectral response 8~14um
Emissivity Digitally adjustable from 0.10 to 1.0
Over range indication LCD will show “----”
Polarity Automatic (no indication for positive polarity);
Minus (-) sign for negative polarity
Diode laser output <1mW,Wavelength 630~670nm,
Class 2 laser product
Operating temp. 0 to 50°C (32 to 122°F)
Storage temp. –10 to 60°C (14 to 140°F)
Relative humidity 10%~90%RH operating,
<80%RH storage
Power supply 9V battery, NEDA 1604A or IEC 6LR61,
or equivalent
Safety “ CE ” Comply with EMC

8
Note:
Field of View: Make sure that the target is larger than
the unit’s spot size. The smaller the target, the closer
you should be to it. When accuracy is critical, make
sure the target is at least twice as large as the spot
size.
2. FRONT PANEL DESCRIPTION
①IR sensor
②LCD Display Laser
pointer beam
③up button
④down button
⑤mode button
⑥Measurement Trigger
⑦Battery Cover
⑧Handle Grip
3. INDICATOR
①Data hold
②Laser ” on” symbols
③Lock symbol
④High alarm and low alarm symbol
⑤°C/°F symbol

9
⑥Low power symbols
⑦Emissivity symbol and value
⑧Temperature values for the MAX
⑨Symbols for MAX
⑩Current temperature value
4. Buttons
①Up button (for EMS,HAL,LAL)
②Down button (for EMS,HAL,LAL)
③MODE button (for cycling
through the mode
loop)
Functional Design
1.the switches of C/F sat in a cell switching
2.In the measuring time up, down keys to adjust the
Emissivity.
3.IN the hold time, up keys to turn on or off the laser Down
keys to turn on or off the backlight
4. To set values for the High Alarm (HAL), Low Alarm (LAL)
and Emissivity (EMS), press the MODE button until the
appropriate code appears in the display, press the
UP and down buttons to adjust the desired values.

10
MODE Button Function
Press the mode button also
allows you to access the
setstate,Emissivity(EMS),
Lock on/off,HAL on/off, HAL
adjustment LOW on/ off,
LOW adjustment,Each time
you press set you advance
through the mode cycle.The
diagram shows the
sequence of functions in the
mode cycle.
EMS adjustment. The
Emissivity(EMS) digitally
adjustable from 0.10 to 1.0,
LOCK on/off. The lock mode
is particularly useful for
continuous monitoring of temperatures. Press the up
button or down button to turn on or off . Press the
Measurement Trigger to confirm the lock measurement
mode. The IR Thermometer will continuously display the
temperaure until press again the Measurement Trigger.
LOCK on/off
HAL on/off
HAL adjustment
LOW on/off
LOW adjustment
EMS adjustment
Table of contents