Trotec TTK 72E User manual

TRT-BA-TTK53E-TTK72E-TC2016-09-004-EN
TTK 53 E / TTK 72 E
EN
OPERATING MANUAL
DEHUMIDIFIER

2 EN
dehumidifier TTK 53 E / TTK 72 E
Table of contents
Notes regarding the operating manual.................................2
Safety .....................................................................................2
Information about the device................................................4
Transport and storage...........................................................6
Assembly and installation.....................................................6
Operation ...............................................................................8
Errors and faults..................................................................12
Maintenance ........................................................................13
Technical annex...................................................................17
Disposal ...............................................................................17
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
TTK 53 E
https://hub.trotec.com/?id=42189
TTK 72 E
https://hub.trotec.com/?id=41804
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Set the device up in an upright and stable position.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.

EN 3
dehumidifier TTK 53 E / TTK 72 E
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The electrical connection must correspond to the
specifications in chapter Technical data.
• Insert the mains plug into a properly secured mains
socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Only transport the device in an upright position with an
emptied condensation tank or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
Intended use comprises:
• dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements
– laundries, holiday homes, camper vans, boats
• maintaining the dryness of:
– storage spaces, archives, laboratories, garages
– bathrooms, wash rooms, changing rooms etc.
Improper use
The device is not intended for industrial use.
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device outdoors.
• Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
• Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the operating manual, especially
the Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.

4 EN
dehumidifier TTK 53 E / TTK 72 E
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Description of the device
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
The device has a control panel for operating and controlling the
functions.
Once the maximum filling level of the condensation tank is
reached or in case the condensation tank is not installed
correctly, the condensation tank indicator light (see chapter
Operating elements) on the control panel is illuminated. The
device switches off. The condensation tank indicator light only
goes out again once the emptied condensation tank is
reinserted.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
The device can reduce the relative humidity of a room to approx.
30%.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.

EN 5
dehumidifier TTK 53 E / TTK 72 E
Device depiction
1
2
3
4
5
6
7
8
9
2
3
10
No. Designation
1 Control panel
2 Transport handle
3 Wheels
4 Air inlet with air filter
5 Condensation drain hose connection
6 Condensation tank
7 Air filter
8 Condensation drain hose
9 Air outlet
10 Colour LED for current room humidity

6 EN
dehumidifier TTK 53 E / TTK 72 E
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
To make the device easier to transport, it is fitted with wheels.
Before transporting the device, observe the following:
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Do not use the power cable to drag the device.
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
• Set up the device in an upright position after transport.
• Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor. Wait
12to24hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
Storage
Before storing the device, proceed as follows:
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Empty and clean the condensation tank prior to storage.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain any possibly remaining condensate.
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust if necessary
• Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and installation
Scope of delivery
• 1x Device
• 1x Condensation drain hose, length: 0.3 m,
diameter: 10 mm
• 1x Air filter
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the Technical data
chapter.
A
B
C
C
D
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Set the device up in an upright and stable position.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.

EN 7
dehumidifier TTK 53 E / TTK 72 E
• When positioning the device, keep a sufficient distance to
heat sources.
• Make sure that no curtains or other objects interfere with
the air flow.
• When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
Inserting the condensation tank
• Ensure that the float inside the condensation tank is
inserted correctly.
• Ensure that the condensation tank is empty and inserted
correctly.
Connecting the power cable
• Insert the mains plug into a properly secured mains
socket.

8 EN
dehumidifier TTK 53 E / TTK 72 E
Operation
Notes:
• Avoid open doors and windows.
• After being switched on, the device operates fully
automatically.
• The fan permanently runs in dehumidification mode until
the set nominal value is reached. The fan keeps running
for approx. 3minutes and then switches off.
Operating elements
12 13 14 16 17
24 23 22 21 20
15
18
11
19
No. Designation Meaning
11 TIMER button Starts programming for the timer
function
12 Plus arrow button Setting the relative room humidity
Setting the number of hours for
the timer function
13 Segment display Indicates the relative room
humidity level
Indicates the desired relative
room humidity during setting
Indicates continuous operation
CO in dehumidification mode
Indicates the number of hours
during timer programming
14 Minus arrow button Setting the relative room humidity
Setting the number of hours for
the timer function
15 Operating modes
indication
Indication of active operating
mode:
Automatic = Automatic mode
Continuous = Dehumidification
(additionally continuous
operation)
Dry Clothes = Laundry drying
function
Air Clean = Ventilation
No. Designation Meaning
16 MODE button Selection button for operating
modes:
Automatic mode
Dehumidification (additionally
continuous operation)
Laundry drying function
Ventilation
17 STAND-BY button Power button:
Switches the device on or off
18 OPERATION indication Illuminated when the device is
switched on
19 AUTOMATIC indication Automatic mode is active
20 CONTINUOUS indication Dehumidification mode is active
Continuous operation is active
21 DRY CLOTHES
indication
Laundry drying mode is active
22 AIR CLEAN indication Ventilation mode is active
23 TANK FULL indication Illuminated when the
condensation tank is full
24 TIMER indication Illuminated when the timer is
programmed
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Press the STAND-BY button(17).
ðThe device starts in automatic mode.
Setting the operating mode
Setting the relative room humidity
You can only change the relative room humidity in
dehumidification mode.
1. Press the arrow buttons(12, 14) to adjust the relative room
humidity. Setting is possible in the range between 30%
and 80% in increments of 5%.
ðThe desired relative room humidity is indicated in the
segment display(13) for approx.5seconds. Then the
current relative room humidity is displayed again.

EN 9
dehumidifier TTK 53 E / TTK 72 E
Dehumidification
The device keeps running until reaching the preselected relative
room humidity. Then the compressor switches off and the fan
keeps running and switches off with a delay. Once the
preselected relative room humidity is exceeded, the compressor
and ventilation switch back on.
The relative room humidity can be preselected in this operating
mode. Setting is possible in the range between 30% and 80%
in increments of 5%.
The fan runs at low speed and the fan speed cannot be
changed.
1. Press the MODE button(16).
ðThe indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the CONTINUOUS
indication(20) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ðDehumidification mode is selected.
ðThe CONTINUOUSindication (20) is illuminated.
4. Press the arrow buttons(12, 14) to adjust the relative room
humidity.
5. Wait for approx. 5seconds in order to save the setting.
Automatic mode
The relative room humidity is preset to 55 % and cannot be
changed.
If the relative room humidity lies between 55 % and 70 %, the
fan automatically switches over to low speed.
Below a relative room humidity of 55%, the compressor
switches off.
Above a relative room humidity of 70 %, the fan runs at the
highest level.
1. Press the MODE button(16).
ðThe indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the AUTOMATIC
indication(19) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ðAutomatic mode is selected.
ðThe AUTOMATICindication (19) is illuminated.
Laundry drying function
The device may be used to dry clothes in a more timely manner.
When positioning the device or a clothes horse, please observe
the minimum distances specified in the technical data.
The device dehumidifies the air constantly and regardless of the
relative room humidity. The fan runs at the highest speed.
The relative room humidity and the fan speed cannot be set in
this operating mode.
1. Press the MODE button(16).
ðThe indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the DRY CLOTHES
indication(21) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ðThe laundry drying function is selected.
ðThe DRY CLOTHESindication (21) is illuminated.
Ventilation
The fan runs at low speed. The compressor does not run.
1. Press the MODE button(16).
ðThe indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the AIR CLEAN
indication(22) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ðVentilation mode is selected.
ðThe AIR CLEANindication (22) is illuminated.
Continuous operation
The device dehumidifies the air constantly and regardless of the
relative room humidity.
The fan runs at low speed and the fan speed cannot be
changed.
1. Press the MODE button(16).
ðThe indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the CONTINUOUS
indication(20) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ðThe CONTINUOUSindication (20) is illuminated.
4. Press the arrow buttons(12, 14) until CO is indicated in the
segment display(13).
5. Wait for approx. 5seconds in order to save the setting.
ðContinuous operation(20) is selected.

10 EN
dehumidifier TTK 53 E / TTK 72 E
Colour LED for current room humidity
Regardless of the operating mode, the colour LED indicates the
current relative room humidity by means of 3 different colours.
LED colour Meaning
Blue Relative room humidity below 55%
Green Optimal relative room humidity between 55%
and 70%
Red Illuminated: relative room humidity above 70%
Flashes: water tank full or not inserted correctly
(accompanied by an acoustic signal)
Setting the timer
Using the timer function, the device can be switched off
automatically after a preset number of hours.
The number of hours can range from 1 to 24 and can be
adjusted in increments of 1h.
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-off
üThe device is switched on.
1. Press the TIMER button(11).
ðThe segment display(13) flashes.
2. Press the arrow buttons(12, 14) to set the desired number
of hours.
3. Wait for approx. 5seconds in order to save the setting.
ðThe TIMERindication (24) is illuminated.
ðThe relative room humidity is indicated in the segment
display(13) again.
ðThe device switches off after the set period of time.
Memory function
The device memorizes the last selected operating mode, and in
dehumidification mode(20) also the set room humidity during
short power failures. If the timer was programmed, this setting
will not be saved.
If the device was disconnected from the mains for a longer time,
the device starts in automatic mode when it is switched back
on.
Auto stop function
If the water tank is full, not inserted correctly or the relative
room humidity has been reached, the compressor will stop
automatically. The fan keeps running and then switches off.
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.
üA suitable hose (diameter: 10mm) is ready for use.
üThe device is switched off.
1. Take the condensation tank out of the device.
2. Push one end of the hose onto the hose connection.
This manual suits for next models
1
Table of contents
Other Trotec Dehumidifier manuals

Trotec
Trotec TTK165ECO User manual

Trotec
Trotec TTR 160 User manual

Trotec
Trotec TTK 75 E User manual

Trotec
Trotec TTK 120 E User manual

Trotec
Trotec TTR 56 E User manual

Trotec
Trotec TTR 400 User manual

Trotec
Trotec TTK 655 S User manual

Trotec
Trotec TTK 90 E User manual

Trotec
Trotec TTK 96 E User manual

Trotec
Trotec 1120001110 User manual

Trotec
Trotec TTK 400 User manual

Trotec
Trotec TTK 75 E User manual

Trotec
Trotec TTK 96 E User manual

Trotec
Trotec TTK 140 S User manual

Trotec
Trotec TTR6600 User manual

Trotec
Trotec TTK 25 E User manual

Trotec
Trotec TTK 175 S User manual

Trotec
Trotec DH 145 S User manual

Trotec
Trotec TTR 160 User manual

Trotec
Trotec TTK 24 E User manual