Trotec TTK 90 E User manual

TRT-BA-TTK90E-TC-004-EN
TTK 90 E
EN
OPERATING MANUAL
DEHUMIDIFIER

1 EN
Operating manual – dehumidifier TTK 90 E
Table of contents
Notes regarding the operating manual.................................1
Safety .....................................................................................1
Information about the device................................................3
Transport and storage...........................................................5
Assembly and installation.....................................................5
Operation ...............................................................................7
Errors and faults..................................................................10
Maintenance ........................................................................11
Technical annex...................................................................15
Disposal ...............................................................................15
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Notice
This signal word indicates important information
(e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
TTK 90 E
https://hub.trotec.com/?id=41398
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Set the device up in an upright and stable position.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

EN 2
Operating manual – dehumidifier TTK 90 E
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The electrical connection must correspond to the
specifications in chapter Technical data.
• Insert the mains plug into a properly secured mains
socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk.
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.
• Ensure that the air inlet and outlet are not obstructed.
• Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.
• Only transport the device in an upright position with an
emptied condensation tank or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
Intended use comprises:
• dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements
– laundries, holiday homes, camper vans, boats
• maintaining the dryness of:
– storage spaces, archives, laboratories, garages
– bathrooms, wash rooms, changing rooms etc.
Improper use
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device outdoors.
• Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
• Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the operating manual, especially
the Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.

3 EN
Operating manual – dehumidifier TTK 90 E
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Notice
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch the device off.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Description of the device
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
The device has a control panel for operating and controlling the
functions.
Once the maximum filling level of the condensation tank is
reached or in case the condensation tank is not installed
correctly, the condensation tank indicator light (see chapter
Operating elements) on the control panel is illuminated. The
device switches off. The condensation tank indicator light only
goes out again once the emptied condensation tank is
reinserted.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
The device can reduce the relative humidity of a room to approx.
30 %.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.

EN 4
Operating manual – dehumidifier TTK 90 E
Device depiction
1
2
6
7
8
5
3
4
No. Designation
1 Air outlet
2 Wheels
3 Condensation drain hose connection
4 Air filter
5 Transport handle
6 Condensation tank
7 Air inlet
8 Control panel

5 EN
Operating manual – dehumidifier TTK 90 E
Transport and storage
Notice
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
To make the device easier to transport, it is fitted with wheels.
To make the device easier to transport, it is fitted with a carry
handle.
Before transporting the device, observe the following:
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Do not use the power cable to drag the device.
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
• Set up the device in an upright position after transport.
• Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor. Wait
12to24hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
Storage
Before storing the device, proceed as follows:
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Empty and clean the condensation tank prior to storage.
Drain any possibly remaining condensate.
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust if necessary
• Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and installation
Scope of delivery
• 1x Device
• 1x Air filter
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the Technical data
chapter.
A
B
C
C
D

EN 6
Operating manual – dehumidifier TTK 90 E
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Set the device up in an upright and stable position.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• When positioning the device, keep a sufficient distance to
heat sources.
• Make sure that no curtains or other objects interfere with
the air flow.
• When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
Inserting the air filter
Notice
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
Inserting the condensation tank
• Ensure that the float inside the condensation tank is
inserted correctly.
• Ensure that the condensation tank is empty and inserted
correctly.
Connecting the power cable
• Insert the mains plug into a properly secured mains
socket.

7 EN
Operating manual – dehumidifier TTK 90 E
Operation
• Avoid open doors and windows.
• After being switched on, the device operates fully
automatically.
• The fan permanently runs in dehumidification mode even
after the set nominal value has been reached until the
device is switched off.
Operating elements
910 11 12 13 14 15 16
1718
19
20
21
No. Designation Meaning
9 Condensation tank full
LED
Illuminated when the
condensation tank is full or not
installed correctly
10 Automatic defrost LED Illuminated during automatic
defrosting
11 High fan speed LED Illuminated when a high fan
speed is set (function for
drying laundry)
12 Low fan speed LED Illuminated when a low fan
speed is set
13 Timer LED Illuminated when the timer is
programmed
14 Arrow button up Setting the relative humidity
level (30 to 90 %RH in
increments of 5%)
15 Arrow button down
16 °C/°F button Setting the temperature unit
(°C or °F)
17 Humidity level segment
display
Indicates the current relative
room humidity
Indicates the desired relative
room humidity during setting
18 Temperature/hours
segment display
Indicates the current
temperature in °C or in °F
Indicates the number of hours
during timer programming
19 Timer button Switching the timer function on
or off
Setting the number of hours for
the timer (1 to 12h)
No. Designation Meaning
20 Fan speed button Setting a low or high fan speed
(function for drying laundry)
21 Power button Switching the device on or off
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Press the Power button(21).
ðThe device will start up.
Setting the operating mode
Setting the desired relative room humidity
Setting is possible in the range between 30% and 90 % in
increments of 5%.
1. Press the arrow buttons(14, 15) to adjust the relative room
humidity.
ðThe desired relative room humidity will be indicated on the
humidity level segment display(17).
Setting the fan speed
Using this function you can choose between a low and a high
fan speed (function for drying laundry).
1. Press the fan speed button(20) to select either high or low
fan speed.
ðThe LED for high(11) or low(12) fan speed lights up
depending on the selected setting.
Dehumidification
The device keeps running until reaching the desired relative
room humidity. Once the desired relative room humidity is
exceeded, the compressor switches back on.
The desired relative room humidity can be set within a setting
range from 30 % to 90 % in steps of 5% at any time.
Setting the timer
For the device to switch on or off automatically after a
predefined number of hours (1 to 24h) you can programme the
timer.
The timer can be programmed in increments of 1hour (1to
24h).
Notice
Do not leave the operating device unattended in a
freely accessible room with an activated timer.

EN 8
Operating manual – dehumidifier TTK 90 E
Automatic switch-on
1. Switch off the device.
2. Press the timer button(19) to activate the timer.
ðThe timer LED(13) is illuminated.
ðThe number of hours is shown on the segment
display(18).
3. Press the arrow buttons(14, 15) to set the number of
hours.
ðThe number of hours flashes on the segment
display(18).
4. Wait for approx. 5seconds in order to save the setting.
ðAfter the predefined time, the device switches itself on.
ðThe set operating time will be indicated for a few seconds
on the segment display(18). Afterwards, the current
temperature is displayed again.
Note regarding automatic switch-on:
• Pressing the power button(21) deactivates the automatic
switch-on function.
Automatic switch-off
üThe device is switched on.
1. Press the timer button(19) to activate the timer.
ðThe timer LED(13) is illuminated.
ðThe number of hours is shown on the segment
display(18).
2. Press the arrow buttons(14, 15) to set the number of
hours.
ðThe number of hours flashes on the segment
display(18).
ðAfter the predefined time, the device switches itself off.
ðThe set operating time will be indicated for a few seconds
on the segment display(18). Afterwards, the current
temperature is displayed again.
Note regarding automatic switch-off:
• Pressing the power button(21) deactivates the automatic
switch-off function.
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.
üA suitable hose (diameter= 1/2inch) is ready for use.
üThe device is switched off.
1. Unscrew the cover from the condensation drain hose
connection(3).
2. Remove the rubber plug.
3. Keep the cover and rubber stopper for later use.
4. Push one end of the hose onto the hose connection.
1/2''

9 EN
Operating manual – dehumidifier TTK 90 E
5. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. Please observe that the
hose must not be kinked.
Remove the hose if you want to collect the condensate in the
condensation tank again. Allow the hose to dry prior to storage.
The hose can be connected in any operating mode for
continuous operation.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting. The fan keeps running.
The automatic defrost LED(10) is illuminated throughout the
defrost process.
The duration of the defrost process can vary. Do not switch the
device off during automatic defrost. Do not remove the mains
plug from the mains socket.
Drying laundry
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe
the minimum distances specified in the technical data.
For drying laundry the following values should be selected:
• cupboard dry = 46 % relative humidity
• iron dry = 58 % relative humidity
• slightly dried = 65 % relative humidity
If necessary, use a measuring device to determine the humidity
level.
1. Press the fan speed button(20) to set the high fan speed.
ðThe LED for high fan speed(11) will be illuminated.
ðThe function for drying laundry is activated.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• If necessary, remove the condensation drain hose and any
residual fluid from it.
• Empty the condensation tank, if need be.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Storage chapter.
Other manuals for TTK 90 E
1
Table of contents
Other Trotec Dehumidifier manuals

Trotec
Trotec TTP 5 E User manual

Trotec
Trotec TTK 100 S User manual

Trotec
Trotec TTR 55 S User manual

Trotec
Trotec TTK 70 S User manual

Trotec
Trotec TTK 96 E User manual

Trotec
Trotec TTK 125 S User manual

Trotec
Trotec TTK 100 S User manual

Trotec
Trotec TTK 27 HEPA User manual

Trotec
Trotec TTK 30 S User manual

Trotec
Trotec TTR 2800 User manual

Trotec
Trotec TTK 400 User manual

Trotec
Trotec TTK 68 E User manual

Trotec
Trotec TTR 160 User manual

Trotec
Trotec TTR 50 E User manual

Trotec
Trotec TTK 500 User manual

Trotec
Trotec TTK 125 S User manual

Trotec
Trotec TTK 70 HEPA User manual

Trotec
Trotec TTK 140 S User manual

Trotec
Trotec DH 15 User manual

Trotec
Trotec TTK 50 E User manual