Trotec TTK 400 User manual

TRT-BA-TTK400-TC2018-63-005-EN
TTK 400
EN
ORIGINAL INSTRUCTIONS
DEHUMIDIFIER

2 EN
dehumidifier TTK 400
Table of contents
Notes regarding the instructions ..........................................2
Safety .....................................................................................2
Information about the device................................................6
Transport and storage...........................................................7
Assembly and installation.....................................................8
Operation .............................................................................10
Available accessories..........................................................11
Errors and faults..................................................................11
Maintenance ........................................................................12
Technical annex...................................................................16
Disposal ...............................................................................22
Declaration of conformity ...................................................22
Notes regarding the instructions
Symbols
Danger
This symbol indicates dangers to life and health of
persons due to the flammable substanceR454C.
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
You can download the current version of the instructions and
the EUdeclaration of conformity via the following link:
TTK 400
https://hub.trotec.com/?id=40698
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Set the device up in an upright and stable position.
• Let the device dry out after a wet clean. Do not operate it
when wet or when in moist surroundings.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device and never
use it as source of ignition.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

EN 3
dehumidifier TTK 400
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The electrical connection must correspond to the
specifications in chapter Technical data.
• Insert the mains plug into a properly secured mains
socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Only transport the device in an upright position with an
emptied condensation tank or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Safety warnings for devices containing flammable
refrigerants
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Please note that the refrigerant is odourless.
• Only install the device in compliance with the national
installation regulations.
• Observe the national gas regulations.
• Only install, operate and store the device TTK 400 in a
room measuring more than 4m2.
• Store the device in a way that no mechanical damage can
occur.
• Please note that the connected ducts must not contain any
sources of ignition.
• R454C comes with a low GWP factor (Global Warning
Potential) of146 and an ODP (ozone depletion potential)
of0.
• Observe the maximum refrigerant capacity in the technical
data.
• Do not drill through or burn.
• Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
• Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
• Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
• Unventilated rooms, in which the device is installed,
operated or stored, must be built in a way to ensure that
potentially leaking refrigerant cannot accumulate. This
serves to avoid fire or explosion hazards resulting from an
ignition of the refrigerant by an electric furnace, cooking
stove or another ignition source.
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Intended use
Only use the device as mobile construction dryer for drying and
dehumidifying room air (e.g. after water damages from burst
pipes or flooding) whilst adhering to the technical data. The
construction dryer can be used at low temperatures of about
5°C.
Intended use comprises:
• drying and dehumidifying:
– production plants, underground rooms
– store rooms, archives, laboratories
– rooms and areas after water damages from burst pipes
or flooding

4 EN
dehumidifier TTK 400
• maintaining the dryness of:
– instruments, devices, files
– electric control devices, boiler plants, turbines and pipe
systems in power plants
– moisture-sensitive loads etc.
Improper use
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device outdoors.
• Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
• Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the instructions, especially the
Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
The following label is attached to the device in German, English
and French.
Operating manual
1.The dehumidifier is designed for 1/N/PEN 230V/ 50Hz
single-phase current with earth connector. 16Afuse.
2.If cable drums etc. are used, they always have to be
completely unrolled during operation! When connecting several
dehumidifiers to a cable drum, always observe total power and
fusing specifications!
3.Socket CEE 7/7:
The dehumidifier must only be operated with ground
connection!
4. The device must be positioned in a way that the air inlet and
outlet grids are not being blocked.
5. The condensate can be permanently discharged from the
dehumidifier via the hose connection. To do so, the condensate
discharge line must be laid with a continuous decline all the
way to the drain.
Alternatively, you can set up a water collection container next
to the device. Due to the high dehumidification performance,
we recommend using a container with a volume of at
least90litres. Once the water collection container is full, the
dehumidifier does not switch off automatically. For this reason,
always make sure to empty the container in time.
To do so, the condensate discharge line must be laid with a
continuous decline all the way to the drain.
If you use a separate water collection container, cut the
condensation drain hose connected to the dehumidifier right
below the upper part of the container (or above the maximum
water level inside the container). If the hose end is positioned
below the water level in the collection container, it may affect
the condensate discharging properly from the dehumidifier,
which will lead to water leaking out uncontrollably from the
dehumidifier.
See operating manual when operating with integrated
condensate pump.
6. Room temperatures below approx.18°C may cause the
(extensive) formation of ice at the dehumidifier's cooling
element(air intake side). The ice will quickly defrost
automatically and regularly. The fan in the dehumidifier
switches off during the defrosting process. The defrosting time
depends on the temperature.
7. After switching the dehumidifier off, wait at least5minutes
until switching it on again. Otherwise damages on the device
may occur.
8. Cleaning: In order to guarantee a high dehumidification
performance, clean the device regularly. Always disconnect the
mains plug prior to cleaning! Clean the cooling grids of the
dehumidifier's air inlet every4-6weeks depending on their
degree of contamination (see instructions).

EN 5
dehumidifier TTK 400
The connection of the condensate discharge and the attached
condensation hose should be disconnected after each use. In
addition, they should be cleaned with compressed air in the
opposite direction of the water current direction. Otherwise,
contaminations and blockage may occur inside the condensate
discharge line, and water may uncontrollably leak out of the
lower part of the dehumidifier.
It is best to use air filters which also have to be cleaned with
compressed air and/or water on a regular basis, depending on
their degree of contamination.
Transport and storage
The device can be transported and stored in vertical and
horizontal position. Operation must only be carried out in a
vertical position! Other operating positions will lead to a
complete device failure!
Note1 for operation: Optimal room temperatures
At room temperatures below12°C, the room should be heated
in order to optimise energy efficiency and to reduce drying
periods. For this purpose, preferably use an electric heater. Do
not under any circumstances use direct oil or gas heaters
(devices without flue pipe connection) as these release large
amounts of water vapour into the room air. This will extremely
extend the drying periods and increase energy costs. The ideal
operating temperature for efficient drying is between15–
25°C. In order to carry out a proper dehumidification process
and to optimise flowrates, position the electric heater as far
away from the dryer as possible.
Note2 for operation: Air distribution with fans
If the areas to be dehumidified are in several different rooms,
we recommend using one fan per room in rooms where no
dehumidifier has been set up. This will significantly reduce the
drying period. Always keep the doors between the individual
rooms open. Otherwise, a dehumidifier has to be installed in
each room. All windows and exterior doors must to be shut
during the drying process!
TTK400
Follow the manual
This symbol indicates that the operating manual must
be observed.
Follow the repair manual
Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification. A
corresponding repair manual is available from the
manufacturer upon request.
Residual risks
Danger
RefrigerantR454C!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames
and other ignition sources. No smoking.
P381– Eliminate all ignition sources if safe to do so.
P403 – Store in a well-ventilated place.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

6 EN
dehumidifier TTK 400
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Description of the device
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
The condensate is discharged through a pressure-resistant pipe
connection by means of a condensation drain hose. For the
collection you can for instance place a sufficiently dimensioned
collection container beside the construction dryer.
Optionally, the condensed water can also be discharged from
the device by means of a retrofitted condensate pump (see
chapter Installing the condensate pump).
For easy operation and transport, the device is fitted with an
on/ off switch, an operating hours counter, a transport handle
and wheels. Two feet with rubber buffers prevent the device
from rolling away.
The device can reduce the relative humidity of a room to approx.
35%.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.

EN 7
dehumidifier TTK 400
Device depiction
TTK 400
TTK 400
1
2
3
12
11
10
TTK 400
ON
80% 20%
60% 30%
40%
TTK 400
4
5
6
78
9
No. Designation
1 Transport handle
2 Carrying handle
3 Wheels
4 On/off switch
5 Air filter
6 Mains power cable
7 Power cable holder
8 Operating hours counter
(optionally: dual counter for operating and kilowatt hours)
9 Air outlet
10 Feet with rubber buffers
11 Condensation drain hose connection
12 Air inlet with slot for air filter
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
To make the device easier to transport, it is fitted with a
transport handle and two wheels.
Before transporting the device, observe the following:
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Do not use the power cable to drag the device.
• Do not incline the device by more than 45°, for otherwise
the device could be damaged.
• Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
• Set up the device in an upright position after transport.
• After having transported the device in horizontal position,
leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor. Wait
12to24hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. Any warranty claims will be voided
in this case.
Storage
Before storing the device, observe the following:
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain any possibly remaining condensate.
When the device is not being used, observe the following
storage conditions:
• Only store the device in a room measuring more than 4m2.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust, if necessary
• Place no further devices or objects on top of the device to
prevent it from being damaged.

8 EN
dehumidifier TTK 400
Assembly and installation
Scope of delivery
• 1x Device
• 1x Air filter
• 1x Condensation drain hose, 19mm diameter
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the Technical data
chapter.
A
B
C
C
D
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Set the device up in an upright and stable position.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• When positioning the device, keep a sufficient distance to
heat sources.
• Make sure that no curtains or other objects interfere with
the air flow.
• When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
Relocating the transport handle
Depending on your requirements, the transport handle can be
installed horizontally or vertically. To adjust the position of the
transport handle, carry out the following steps on both sides of
the device:
1. Loosen and remove the screws marked at positions(13),
(15) and(16).
2. Turn the transport handle by 90° and attach it to the
device in the desired position.
3. Insert the screws from positions(13) and(15) into the
openings of position(13) and(16) and tighten them.
4. Insert the screw from position(16) into the opening of
position(15) and tighten it.
TTK 400
TTK 400
13
14
15
16
TTK 400
TTK 400

EN 9
dehumidifier TTK 400
Inserting the air filter
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
TTK 400
TTK 400
Positioning the condensation drain hose
For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.
üA suitable hose (diameter: 19mm) is ready for use.
üThe device is switched off.
1. Connect the condensation drain hose to the condensation
hose connection(11) at the device.
2. Make sure that the condensation drain hose is properly
connected to the device and free of damage.
3. Depending on the application, position the end of the
condensation drain hose as follows:
ðPlace a sufficiently dimensioned container (at least
90litres) beside the device and insert the hose end.
Check the filling level of the container regularly.
TTK 400
TTK 400
ðPosition the end of the condensation drain hose above a
water drain. For larger distances, a longer hose of the
same type can also be used.
TTK 400
TTK 400
ðThe device can also be operated with a condensate
pump. Contact your Trotec customer service.

10 EN
dehumidifier TTK 400
4. Make sure that the condensation drain hose is installed
with a continuous decline.
TTK 400
TTK 400
Operation
• Avoid open doors and windows.
• After being switched on, the device operates fully
automatically.
• During operation with an external hygrostat (optional) the
fan continues to run in dehumidification mode until the
device is switched off even after having reached the set
target value.
Operating elements
16
18
19
4
17
No. Designation Meaning
4 On/off switch For switching the device on or off
16 OFF position Device switched off
17 ON position Device switched on
18 Operating hours
counter
Indication of operating hours
(optionally: dual counter for
operating and kilowatt hours)
19 Hygrostat (optional) For setting the desired humidity
level
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Make sure that the condensation drain hose has been
properly laid and connected. Do not create tripping
hazards.
2. Make sure that the condensation drain hose is neither
kinked nor jammed and that there are no objects on the
condensation drain hose.
3. Make sure that the condensate can run off properly.
4. Turn the on/ off switch(4) to the ONposition(17).
ðThe device is switched on.
ðThe compressor always starts with a delay of approx. 7s.
ðThe fan starts approx.10s after that.
Continuous operation mode
In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity.
Hygrostat operation mode (optional)
The device can also be operated with a hygrostat. The hygrostat
switches the device on or off depending on the relative
humidity.
If you choose to operate the device with an optional hygrostat,
set the desired relative humidity at the hygrostat (see
instructions of the optional hygrostat).
In doing so, observe the switching point. Provided the external
hygrostat activates the compressor via the set humidity value,
then hygrostat and drying unit operate correctly. You can tell the
incorrect operation of the external hygrostat if the compressor of
the device operates below the set value and switches off above
it. In this case you need to open the hygrostat and reconnect the
connections.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting. The fan keeps running.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.
Other manuals for TTK 400
4
Table of contents
Other Trotec Dehumidifier manuals

Trotec
Trotec TTK 1500 User manual

Trotec
Trotec TTK 128 E User manual

Trotec
Trotec TTR 56 E User manual

Trotec
Trotec TTK 75 E User manual

Trotec
Trotec TTR 160 User manual

Trotec
Trotec ttk 71 e User manual

Trotec
Trotec TTR 55 S User manual

Trotec
Trotec TTK 125 S User manual

Trotec
Trotec TTK 170 S User manual

Trotec
Trotec TTK 65 E User manual

Trotec
Trotec TTK 655 S User manual

Trotec
Trotec TTR 56 E User manual

Trotec
Trotec TTK 120 E User manual

Trotec
Trotec TTR 400 D User manual

Trotec
Trotec TTK 400 User manual

Trotec
Trotec TTK 125 S User manual

Trotec
Trotec TTR 200 User manual

Trotec
Trotec TTK 67 E User manual

Trotec
Trotec MD 05-30 User manual

Trotec
Trotec TTR6600 User manual