Table of contents
Notes regarding the operating manual.................................2
Safety .....................................................................................2
Information about the device................................................5
Transport and storage...........................................................6
Assembly and start-up..........................................................6
Operation ...............................................................................8
Errors and faults..................................................................11
Maintenance ........................................................................12
Technical annex...................................................................15
Disposal ...............................................................................18
Notes regarding the operating manual
Symbols
Danger
This symbol indicates dangers to the life and health of
persons due to extremely flammable gas.
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
TTK 60 E
https://hub.trotec.com/?id=44217
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Only put up the device in an upright, stable position on firm
ground.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover the device during operation.
• Do not sit on the device.
• This appliance is not a toy. Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

EN 3
dehumidifier TTK 60 E
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The mains connection must correspond to the
specifications in the Technical annex.
• Insert the mains plug into a properly fused mains socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Only transport the device in an upright position with an
emptied condensation tank or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Safety warnings for devices containing flammable
refrigerants
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Please note that the refrigerant is odourless.
• Only install the device in compliance with the national
installation regulations.
• Observe the national gas regulations.
• Only install, operate and store the device TTK 60 E in a
room measuring more than 4m2.
• Store the device in a way that no mechanical damage can
occur.
• Please note that the connected pipelines must not contain
any sources of ignition.
• R290 is a refrigerant that complies with European
environmental regulations. No part of the cooling circuit
may be perforated.
• Observe the maximum refrigerant capacity in the technical
data.
• Do not drill through or burn.
• Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
• Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
• Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
• Unventilated rooms, in which the device is installed,
operated or stored, must be built in a way to ensure that
potentially leaking refrigerant cannot accumulate. This
serves to avoid fire or explosion hazards resulting from an
ignition of the refrigerant by an electric furnace, cooking
stove or another ignition source.
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
Intended use comprises:
• dehumidifying and drying:
– living rooms, bedrooms and basements
– holiday homes, camper vans
• maintaining the dryness of:
– storage spaces, archives, laboratories, garages
– changing rooms etc.

4 EN
dehumidifier TTK 60 E
Foreseeable misuse
The device is not intended for industrial use.
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device out of doors.
• Do not make any unauthorised modifications, alterations or
structural changes to the device.
• Any use other than the intended use is regarded as a
reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the operating manual, especially
the Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
TTK60E
Follow the manual
This symbol indicates that the operating manual must
be observed.
Follow the repair manual
Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification. A
corresponding repair manual is available from the
manufacturer upon request.
Residual risks
Danger
Natural refrigerant propane (R290)!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P410+P403 – Protect from sunlight. Store in a well-
ventilated place.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch the device off.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.

EN 5
dehumidifier TTK 60 E
Information about the device
Device description
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
The device has a control panel for operating and controlling the
functions.
Once the maximum filling level of the condensation tank is
reached or in case the condensation tank is not installed
correctly, the condensation tank indicator light (see chapter
Operation) on the control panel is illuminated. The device
switches off. The condensation tank indicator light only goes out
again once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
The device can reduce the relative humidity of a room to
approx. 35 %.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.
Device depiction
1
2
8
3
4
5
6
2
7
3
No. Designation
1 Control panel
2 Transport handle
3 Air outlet
4 Wheels
5 Condensation hose connection with sealing cap
6 Power cable holder
7 Air inlet with air filter
8 Condensation tank with filling level indicator

6 EN
dehumidifier TTK 60 E
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
Please note that additional transport regulations might apply to
devices containing flammable refrigerants. The equipment's
arrangement and the maximum number of components to be
transported together can be gathered from the applicable
transport regulations.
To make the device easier to transport, it is fitted with a carry
handle.
To make the device easier to transport, it is fitted with wheels.
Before transporting the device, observe the following:
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Do not use the power cable to drag the device.
• Only wheel the device on a level and smooth surface.
After transporting the device, proceed as follows:
• Set up the device in an upright position after transport.
• Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor. Wait
12to24hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
Storage
Before storing the device, proceed as follows:
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
When the device is not being used, observe the following
storage conditions:
• Only store the device in a room measuring more than 4m2.
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust, if necessary
• Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and start-up
Scope of delivery
• 1x Device
• 1x Air filter
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.
A
B
C
C
D
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Only put up the device in an upright, stable position on firm
ground.

EN 7
dehumidifier TTK 60 E
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• When positioning the device, keep a sufficient distance to
heat sources.
• Make sure that no curtains or other objects interfere with
the air flow.
• When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
Inserting the condensation tank
• Ensure that the float inside the condensation tank is
inserted correctly.
• Ensure that the condensation tank is empty and inserted
correctly.
Connecting the power cable
• Insert the mains plug into a properly secured mains
socket.

8 EN
dehumidifier TTK 60 E
Operation
Notes:
• Avoid open doors and windows.
• After being switched on, the device operates fully
automatically.
• The fan permanently runs in dehumidification mode even
after the set nominal value has been reached until the
device is switched off.
Operating elements
910 11
15
12
13
14
16
17
18
19
20
21
No. Designation Meaning
9 Plusbutton For increasing the desired relative
room humidity value in a range
between 35% and 80%
10 Segment display Indicates the current relative room
humidity.
Indicates the desired relative room
humidity during setting.
11 Minus button For reducing the desired relative
room humidity value in a range
between 35% and 80%
12 TANK FULL LED Illuminated in red when the
condensation tank is full or not
installed correctly.
13 CONTINUOUS LED Illuminated in green when continuous
operation mode is activated.
14 FILTER RESET LED Lights up after 250 operating hours
to remind you to clean the filter.
15 FILTER button Resets the FILTER RESET LED.
16 ON/OFF button For switching the device on or off
17 POWER LED Illuminated in green when the device
is switched on.
18 FAN SPEED button For setting the fan speed
No. Designation Meaning
19 Fan speed
indication
HIGH: high fan speed (laundry drying
function)
LOW: low fan speed
20 TIMER button For activating the timer (2 or 4hours)
21 Timer indication Indicates the number of hours for the
timer (2 or 4hours).
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
1. Press the ON/OFF button(16).
ðThe unit starts to dehumidify.
Setting the operating mode
Setting the desired relative room humidity
You can change the desired relative room humidity at any time.
1. Use the plus(9) or minus(11) buttons to select the desired
relative humidity value. Setting is possible in the range
between 35% and 80%.
ðThe desired relative room humidity is indicated on the
segment display(10) for approx.5s. Then the current
relative room humidity will again be displayed.
Setting the fan speed
You can choose between low and high fan speed (laundry drying
function) at any time.
1. Press the FAN SPEED button(18) to select either low or
high fan speed (function for drying laundry).
ðThe selected fan speed is indicated by the fan speed
indication(19).
Dehumidification
The device keeps running until reaching the desired relative
room humidity. Then the compressor switches off and the fan
keeps running. Once the desired relative room humidity is
exceeded, the compressor switches back on.
The desired relative room humidity can be set at any time within
a setting range of 35% to 80%.
You can choose between low and high fan speed (laundry drying
function).

EN 9
dehumidifier TTK 60 E
Continuous operation
The device dehumidifies the air constantly and regardless of the
current humidity level.
1. Press the minus button(11) until CO is indicated on the
segment display(10).
ðThe CONTINUOUS LED(13) is illuminated in green.
ðThe dehumidifier now works in continuous operation
mode.
Setting the timer
The timer has the following functionality:
• automatic switch-off upon expiry of a preset number of
hours (2h or 4h).
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-off
üThe device is switched on.
1. Press the TIMER button(20) until the LED for the desired
number of hours (2h or 4h) is illuminated.
2. Wait for approx. 5seconds in order to save the setting.
ðThe timer setting equals the desired number of hours.
ðThe device switches off after the set period of time.
Note regarding automatic switch-off:
• Pressing the ON/OFF button(16) deactivates the automatic
switch-off function.
Auto stop function
If the water tank is full, not inserted correctly or the desired
relative room humidity has been reached, the device will stop
automatically.
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect a suitable condensation drain hose to the device.
üA suitable hose (diameter= 1/2") is ready for use.
üThe device is switched off.
1. Take the condensation tank out of the device.
2. Remove the sealing cap from the hose connection.
3. Remove the rubber plug.
4. Attach the rubber plug to the drain located within the
device.

10 EN
dehumidifier TTK 60 E
5. Put the condensation tank back in.
6. Screw the adapter for the condensation drain hose onto
the hose connection.
7. Push one end of the hose onto the adapter.
8. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. Please note that the
hose must not be kinked.
Remove the hose if you want to collect the condensate in the
condensation tank again. Allow the hose to dry prior to storage.
Automatic defrost
At low ambient temperatures (below 15°C), ice may form at the
evaporator during dehumidification. The device will then carry
out an automatic defrost. Dehumidification is briefly interrupted
during defrosting.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.
Drying laundry
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe
the minimum distances specified in the technical data.
The following humidity values are suitable for drying laundry:
• cupboard dry= 46% relative humidity
• iron dry= 58% relative humidity
• slightly dried= 65% relative humidity
Adjust the settings for the relative humidity level to the device
(e.g. 60% relative humidity for iron dry laundry). If necessary,
use a measuring device to determine the humidity level.
1. Select the highest fan speed using the FAN SPEED
button(18).
ðThe function for drying laundry is activated.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• If necessary, remove the condensation drain hose and any
residual fluid from it.
• Empty the condensation tank, if need be.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Transport and storage
chapter.
Table of contents
Other Trotec Dehumidifier manuals

Trotec
Trotec ttk 71 e User manual

Trotec
Trotec TTR 55 S User manual

Trotec
Trotec TTK 170 S User manual

Trotec
Trotec TTK 54 E User manual

Trotec
Trotec TTK 165 ECO User manual

Trotec
Trotec TTK 53 E User manual

Trotec
Trotec TTK 65 E User manual

Trotec
Trotec TTR 56 E User manual

Trotec
Trotec TTK 800 User manual

Trotec
Trotec TTP 1 E User manual

Trotec
Trotec TTR 2000 User manual

Trotec
Trotec TTK 95 E User manual

Trotec
Trotec TTK 25 E User manual

Trotec
Trotec TTK 50 S User manual

Trotec
Trotec TTK 40 E User manual

Trotec
Trotec TTK 166 ECO User manual

Trotec
Trotec TTK 30 S User manual

Trotec
Trotec TTR 55 E User manual

Trotec
Trotec TTR 10000 User manual

Trotec
Trotec TTK 120 E User manual