Trotec TTK QUBE User manual

TRT-BA-TTK-QUBE-TC2021-07-002-EN
TTK QUBE
EN
ORIGINAL INSTRUCTIONS
DEHUMIDIFIER

2 EN
dehumidifier TTK Qube
Table of contents
Notes regarding the instructions ..........................................2
Safety .....................................................................................2
Information about the device................................................5
Transport and storage...........................................................6
Assembly and installation.....................................................7
Operation ...............................................................................9
Available accessories..........................................................10
Errors and faults..................................................................11
Maintenance ........................................................................12
Technical annex...................................................................15
Disposal ...............................................................................18
Declaration of conformity ...................................................18
Notes regarding the instructions
Symbols
Danger
This symbol indicates dangers to the life and health of
persons due to flammable refrigerants.
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information
(e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of the instructions and
the EUdeclaration of conformity via the following link:
TTK Qube
https://hub.trotec.com/?id=44931
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Only put up the device in an upright, stable position on firm
ground.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

EN 3
dehumidifier TTK Qube
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The mains connection must correspond to the
specifications in the Technical annex.
• Insert the mains plug into a properly secured mains
socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Only transport the device in an upright position with an
emptied condensation tank or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Safety warnings for devices containing flammable
refrigerants
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Please note that the refrigerant is odourless.
• Only install the device in compliance with the national
installation regulations.
• Observe the national gas regulations.
• Only install, operate and store the device TTK Qube in a
room measuring more than 4m2.
• Store the device in a way that no mechanical damage can
occur.
• Please note that the connected pipelines must not contain
any sources of ignition.
• No part of the cooling circuit may be perforated.
• Observe the maximum refrigerant capacity in the technical
data.
• Do not drill through or burn.
• Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
• Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
• Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
• Unventilated rooms, in which the device is installed,
operated or stored, must be built in a way to ensure that
potentially leaking refrigerant cannot accumulate. This
serves to avoid fire or explosion hazards resulting from an
ignition of the refrigerant by an electric furnace, cooking
stove or another ignition source.
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.

4 EN
dehumidifier TTK Qube
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
Intended use comprises:
• dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements
– laundries, holiday homes, camper vans, boats
• maintaining the dryness of:
– storage spaces, archives, laboratories, garages
– bathrooms, wash rooms, changing rooms etc.
Foreseeable misuse
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device outdoors.
• Do not make any unauthorised modifications, alterations or
structural changes to the device.
• Any use other than the intended use is regarded as a
reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the instructions, especially the
Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
TTKQube
Follow the manual
This symbol indicates that the operating manual must
be observed.
Follow the repair manual
Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification. A
corresponding repair manual is available from the
manufacturer upon request.

EN 5
dehumidifier TTK Qube
Residual risks
Danger
Refrigerant 2,3,3,3-Tetrafluoropropene (R1234yf)!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P381– Eliminate all ignition sources if safe to do so.
P403 – Store in a well-ventilated place.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Description of the device
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
The device comes with a hot gas automatic defrost system.
Here, the hot gas of the refrigerant circuit is used actively for
fast and effective defrosting. This makes the device operate
effectively even at temperatures below 15°C.
The comfort function allows the device to operate particularly
quietly and thus makes it suitable for the use in inhabited
surroundings.
To discharge the condensate, the device is equipped with an
integrated condensate pump with automatic switch-off function
that is able to operate up to a height of max.10m.
The device can reduce the relative humidity of a room to
approx. 30%.
The device has a control panel for operating and controlling the
functions.

6 EN
dehumidifier TTK Qube
Device depiction
1
2
4
5
3
6
7
8
No. Designation
1Control panel
2Cable holder
3Power cable
4Air outlet
5Carrying handle
6Condensation drain hose connection
7Air inlet
8Air filter
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
Please note that additional transport regulations might apply to
devices containing flammable refrigerants. The equipment's
arrangement and the maximum number of components to be
transported together can be gathered from the applicable
transport regulations.
To make the device easier to transport, it is fitted with a
transport handle.
Before transporting the device, observe the following:
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Do not use the power cable to drag the device.
After transporting the device, proceed as follows:
• Set up the device in an upright position after transport.
Storage
Before storing the device, proceed as follows:
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain any possibly remaining condensate.
When the device is not being used, observe the following
storage conditions:
• Only store the device in a room measuring more than 4m2.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust, if necessary
• stackable: up to 4devices may be stacked on top of one
another
• Place no further devices or objects on top of the device to
prevent it from being damaged.

EN 7
dehumidifier TTK Qube
Assembly and installation
Scope of delivery
• 1x Device
• 1x Air filter
• 1x Condensation drain hose, length: 5m,
diameter: 8mm
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.
A
B
C
C
D
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Only put up the device in an upright, stable position on firm
ground.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• When positioning the device, keep a sufficient distance to
heat sources.
• Make sure that no curtains or other objects interfere with
the air flow.
• When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.

8 EN
dehumidifier TTK Qube
Inserting the air filter
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
Positioning the condensation drain hose
Note
Do not use the device without the condensation drain
hose connected!
üA suitable hose (diameter: 8mm) is ready for use.
üThe device is switched off.
1. Connect the condensation drain hose to the hose
connection.
2. Make sure that the condensation drain hose is properly
connected to the device and free of damage.
3. Depending on the application, position the end of the
condensation drain hose as follows:
ðPlace a sufficiently dimensioned container (at least
90litres) near the device and insert the hose end. The
device is equipped with a pump and is able to pump the
water up to a height of10m. Check the filling level of
the container regularly.
ðCompletely unwind the hose and guide the hose end to
a water drain. Avoid kinking or pinching the hose. The
hose end must not lay in the water!
Connecting the power cable
• Insert the mains plug into a properly secured mains
socket.

EN 9
dehumidifier TTK Qube
Operation
Notes:
• Avoid open doors and windows.
• After being switched on, the device operates fully
automatically.
• The compressor switches on approx.3minutes after the
device has been switched on.
Control panel
9
10
11
12
13
14
No. Designation Meaning
9Dual counter Indication of operating hours and
energy consumption
10 Rotary switch Selection of relative room humidity
(hygrostat)
11 Mains switch Switching the device on and off;
Is illuminated when the device is
switched on
12 Status lamp Flashes slowly during operation;
Flashes quickly in the event of a fault
13 Condensate outlet
button
Manual activation of the condensate
pump
Is illuminated if the condensate pump
is in operation
14 FUNCTION flip
switch
Selecting the comfort or power
function
The device comes equipped with a dual counter. The dual
counter registers both the operating hours and the energy
consumption and is certified according to the MID (Measuring
Instruments Directive 2004/22/EC). The kWh display is
factory-calibrated and may be used for accounting purposes.
Contact your Trotec customer service.
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
1. Switch the device on by setting the mains switch(11) to
positionI.
2. Make sure that the mains switch button(11) is illuminated
and that the status lamp(12) flashes slowly.
3. Adjust the room humidity level with the rotary switch (10).
4. Once condensate forms, the condensate pump is activated
automatically. To activate the condensate pump manually,
press the condensate outlet button(13). When the
condensate pump is activated, the condensate outlet
button(13) is illuminated.
Continuous operation
In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity. To start continuous
operation mode, set the rotary switch(10) to Max.
Adjusting the room humidity level
1. Set the desired humidity level via the rotary switch(10) of
the hygrostat.
2. After approx. 24hours, check the humidity with a
thermohygrometer.
ðIf the air is too dry (insufficient humidity level), turn the
rotary switch (10) slightly towards MIN.
ðIf the air is too humid, turn the rotary switch (10) slightly
towards MAX.
3. Wait 24hours every time you have changed the hygrostat
setting and repeat the process until the desired room
humidity is reached.
ðOnce the set room humidity is reached, the compressor
and the fan of the device switch off automatically.
ðIf the set room humidity is exceeded, the compressor
and the fan switch back on automatically. The room air
is dehumidified.

10 EN
dehumidifier TTK Qube
Comfort function
The device operates particularly quietly in comfort mode. To
activate the comfort function, set the FUNCTION flip switch(14)
to I. To return to the power function, set the FUNCTION flip
switch(14) to II.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device carries out an automatic
defrost by means of the hot gas feed. Here, a hot cooling agent
is led into the iced evaporator for its surfaces to defrost.
The hot gas automatic defrost system integrated in the device
automatically switches on the defrost cycle at regular intervals.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.
Temperature limitation (overheating protection)
The device comes with a temperature limitation. It serves to
protect e.g. the compressor from overheating.
• Upper temperature limit: +35°C +/- 2°C
• Lower temperature limit: -3°C +/- 2°C
If the ambient temperature exceeds or falls below these limits,
the device automatically switches off the compressor; only the
fan will keep running. This feature protects the device from
overloading since high temperatures and high humidity levels
expose the device to extreme stresses. Moreover, drying is no
longer economical at such high temperatures and also poses
dangers for the inventory of the room to be dried. Please note
that the switch-off function works with a switch-on hysteresis
of -2°C.
Info
The compressor always starts with a delay. This
protects the compressor and thus increases its
lifetime. When you switch on the device, the
compressor will switch on with a delay of
approx.3min. This delay is also enabled in hygrostat
operation. If the room humidity exceeds the setting of
the selection switch, the compressor will only switch
back on after a delay.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Press the condensate outlet button(13) to drain the
residual water.
• Switch the device off by setting the mains switch to
position0.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• If necessary, remove the condensation drain hose and any
residual fluid from it.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Transport and storage
chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Designation Article number
Air filter for TTK Qube 7.160.000.014
Condensation drain hose 7.331.000.474
Table of contents
Other Trotec Dehumidifier manuals

Trotec
Trotec TTR 2800 User manual

Trotec
Trotec TTK 120 S User manual

Trotec
Trotec TTK 655 S User manual

Trotec
Trotec TTR 200 User manual

Trotec
Trotec TTR 160 User manual

Trotec
Trotec TTK 125 S User manual

Trotec
Trotec TTR 56 E User manual

Trotec
Trotec TTK 400 User manual

Trotec
Trotec TTK 54 E User manual

Trotec
Trotec TTK 40 E User manual

Trotec
Trotec TTK 52 E User manual

Trotec
Trotec MD 05-30 User manual

Trotec
Trotec TTK 400 User manual

Trotec
Trotec TTK 25 E User manual

Trotec
Trotec TTK 165 ECO User manual

Trotec
Trotec DH 30 VPR+ User manual

Trotec
Trotec TTK 99 HEPA User manual

Trotec
Trotec TTR 250 EX User manual

Trotec
Trotec TTR 400 User manual

Trotec
Trotec 1120001110 User manual