Trotec TTK 500 User manual

TRT-BA-TTK500-TC220617TTRT04-005-EN
TTK 500
EN
ORIGINAL INSTRUCTIONS
DEHUMIDIFIER

2 EN
dehumidifier TTK 500
Table of contents
Notes regarding the instructions ..........................................2
Safety .....................................................................................2
Information about the device................................................5
Transport and storage...........................................................6
Assembly and start-up..........................................................7
Operation .............................................................................11
Available accessories..........................................................12
Errors and faults..................................................................13
Maintenance ........................................................................14
Technical annex...................................................................18
Disposal ...............................................................................25
Declaration of conformity ...................................................25
Notes regarding the instructions
Symbols
Danger
This symbol indicates dangers to the life and health of
persons due to flammable refrigerants.
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information
(e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of these instructions via
the following link:
TTK 500
https://hub.trotec.com/?id=42346
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
• In the scope of European normative requirements
(EN 60335-1):
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be
made by children without supervision.
• In the scope of International normative requirements
(IEC 60335-1):
This appliance is not intended for use by persons
(including children) with reduced physical sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety. Children should be supervised to ensure
that they do not play with the appliance.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Only put up the device in an upright, stable position on firm
ground.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.

EN 3
dehumidifier TTK 500
• Do not cover the device during operation.
• Do not sit on the device.
• This appliance is not a toy. Keep away from children and
animals.
• Occasionally observe the device during operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The mains connection must correspond to the
specifications in the Technical annex.
• Insert the mains plug into a properly fused mains socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Never insert any objects or limbs into the device.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Only transport the device in an upright position with an
emptied condensation tank or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
• Only use original spare parts, for otherwise safe and
functional operation cannot be ensured.
Safety warnings for devices containing flammable
refrigerants
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate. Unventilated rooms, in
which the device is installed, operated or stored, must be
built in a way to ensure that potentially leaking refrigerant
cannot accumulate. This serves to avoid fire or explosion
hazards resulting from an ignition of the refrigerant by an
electric furnace, cooking stove or another ignition source.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Please note that the refrigerant is odourless.
• Only install the device in compliance with the national
installation regulations.
• Please observe the local regulations.
• Observe the national gas regulations.
• Only install, operate and store the device in a room
measuring more than 4m2.
• Store the device in a way that no mechanical damage can
occur.
• Please note that the connected pipelines must not contain
any sources of ignition.
• R454C comes with a low GWP factor (Global Warning
Potential) of146 and an ODP (ozone depletion potential)
of0.
• Observe the maximum refrigerant capacity in the technical
data.
• Do not drill through or burn.
• Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
• Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
• Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and
air-conditioning or by Trotec.

4 EN
dehumidifier TTK 500
Intended use
Only use the device as mobile construction dryer for drying and
dehumidifying room air (e.g. after water damages from burst
pipes or flooding) whilst adhering to the technical data.
The construction dryer can be used at low temperatures of
about 5°C.
Intended use comprises:
• drying and dehumidifying:
– production plants, underground rooms
– store rooms, archives, laboratories
– rooms and areas after water damages from burst pipes
or flooding
• maintaining the dryness of:
– instruments, devices, files
– electric control devices, boiler plants, turbines and pipe
systems in power plants
– moisture-sensitive loads etc.
Foreseeable misuse
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device out of doors.
• This device must not be used in wet rooms (e.g. laundry
rooms).
• Never immerse the device in water.
• Do not make any unauthorised modifications, alterations or
structural changes to the device.
• Any use other than the intended use is regarded as a
reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the instructions, especially the
Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
Follow the manual
This symbol indicates that the instructions must be
observed.
Follow the repair manual
Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification.
A corresponding repair manual is available from the
manufacturer upon request.
Residual risks
Danger
RefrigerantR454C!
H221 – Flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P381– Eliminate all ignition sources if safe to do so.
P403 – Store in a well-ventilated place.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Risk of electric shock!
The device does not have the appropriate protection
class for use in wet rooms.
There is a risk of electric shock!
Never use the device in wet rooms (e.g. in bathrooms
and laundry rooms) and never immerse the device in
water!

EN 5
dehumidifier TTK 500
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch the device off.
2. Disconnect the device from the mains feed-in: Hold onto
the mains plug while pulling the power cable out of the
mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Device description
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
The condensate is discharged through a pressure-resistant pipe
connection by means of a condensation drain hose. For the
collection you can for instance place a sufficiently dimensioned
collection container beside the construction dryer.
Optionally, the condensed water can also be discharged from
the device by means of a retrofitted condensate pump (see
chapter Installing the condensate pump).
For easy operation and transport, the device is fitted with an
on/ off switch, an operating hours counter, a transport handle
and wheels. Two feet with rubber buffers prevent the device
from rolling away.
The device can reduce the relative humidity of a room to
approx.35%.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.

6 EN
dehumidifier TTK 500
Device depiction
TTK 500
1
2
3
10
11
12
4
6
7
8
9
TTK 500
2
5
No. Designation
1 Transport handle
2 Carrying handle
3 Wheels
4 On/off switch
5 Air filter
6 Mains power cable
7 Power cable holder
8 Operating hours counter (optionally energy meter and
operating hours counter)
9 Air outlet
10 Foot with rubber buffers
11 Condensation hose connection
12 Air inlet with slot for air filter
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
Please note that additional transport regulations might apply to
devices containing flammable refrigerants. The equipment's
arrangement and the maximum number of components to be
transported together can be gathered from the applicable
transport regulations.
To make the device easier to transport, it is fitted with a
transport handle and wheels.
Before transporting the device, observe the following:
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Do not use the power cable to drag the device.
• Only wheel the device on firm and level surfaces.
• On uneven surfaces, carry the device by lifting it by the
carry handles. Ask another person to help you.
• To carry the device up or down stairs, lift it by the transport
handle and by the foot. Ask another person to help you.
After transporting the device, proceed as follows:
• Set up the device in an upright position after transport.

EN 7
dehumidifier TTK 500
Storage
Before storing the device, proceed as follows:
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain any possibly remaining condensate.
When the device is not being used, observe the following
storage conditions:
• Only store the device in a room measuring more than 4m2.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Store the device in a dry location and protected from frost
and heat.
• Store the device in an upright position where it is protected
from dust and direct sunlight.
• If required, use a cover to protect the device from invasive
dust.
• Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and start-up
Scope of delivery
• 1x device
• 1x air filter
• 1x Condensation drain hose, 14mm diameter
• 1x manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.
A
B
C
C
D
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Only put up the device in an upright, stable position on firm
ground.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• When positioning the device, keep a sufficient distance to
heat sources.
• Make sure that no curtains or other objects interfere with
the air flow.
• When positioning the device, secure the device locally with
an RCD(Residual Current Device) which complies with the
appropriate regulations.

8 EN
dehumidifier TTK 500
Relocating the transport handle
Depending on your requirements, the transport handle can be
installed horizontally or vertically. To adjust the position of the
transport handle, carry out the following steps on both sides of
the device:
1. Unscrew or loosen the screw(14).
2. Remove the screw(13).
TTK 500
13
14
15
3. Turn the transport handle by 90°.
TTK 500
14
13
4. Insert the screw(13) in the rivet(15).
5. Tighten the screws(13,14).
Inserting the air filter
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
TTK 500

EN 9
dehumidifier TTK 500
Positioning the condensation drain hose
1. Connect the condensation drain hose to the condensation
hose connection(11) at the device.
2. Make sure that the condensation drain hose is properly
connected to the device and free of damage.
3. Depending on the application, position the end of the
condensation drain hose as follows:
ðPlace a sufficiently dimensioned container (at least
90litres) beside the device and insert the hose end.
Check the filling level of the container regularly.
TTK 500
ðPosition the end of the condensation drain hose above a
water drain. For larger distances, a longer hose of the
same type can also be used.
TTK 500
ðThe device can also be operated with a condensate
pump. Contact your Trotec customer service.
4. Make sure that the condensation drain hose is installed
with a continuous decline.
TTK 500

10 EN
dehumidifier TTK 500
Installing the condensate pump (optional)
1.
TTK 500
2.
TTK 500
3.
TTK 500
4.
TTK 500
5.
TTK 500
6.
TTK 500
Table of contents
Other Trotec Dehumidifier manuals

Trotec
Trotec TTK 75 E User manual

Trotec
Trotec TTK 25 E User manual

Trotec
Trotec TTK 175 S User manual

Trotec
Trotec TTK 54 E User manual

Trotec
Trotec TTR 160 User manual

Trotec
Trotec TTR 55 E User manual

Trotec
Trotec TTR 57 E User manual

Trotec
Trotec TTK 70 HEPA User manual

Trotec
Trotec TTK 105 S HC User manual

Trotec
Trotec TTR 400 User manual

Trotec
Trotec TTR 800 User manual

Trotec
Trotec TTK 120 S User manual

Trotec
Trotec TTK 120 E User manual

Trotec
Trotec TTK 65 E User manual

Trotec
Trotec TTK QUBE User manual

Trotec
Trotec TTK 110 HEPA User manual

Trotec
Trotec TTR 400 D User manual

Trotec
Trotec TTK 90 E User manual

Trotec
Trotec TTK 125 S User manual

Trotec
Trotec TTK 26 E User manual