Application Note: Security, Alarm System www.topkodas.lt 2 | EN
GTalarm2 is a user-friendly security system that monitors your site’s
detectors and alarms. Fully programmable, the module GTalarm2
allows you to control hundreds of critical security functions from one
menu-driven interface.
The system consists of a central control unit, an operating panel, and
up to 32 protection points. While monitoring protection points 24 hours
a day the controller itself is electronically monitored by trained central
monitoring station personnel. If a hazard or security breach occurs, the
appropriate authorities (police, fire) are alerted.
All functions are accessed through the system operating panels or
through card/key readers.
Attractive, easy-to-use operating panel.
Control of up to 32 protection points from one central location.
Manual activation or deactivation of any function.
Ability to on in either the AWAY or STAY mode.
Ability to bypass points for maintenance or service.
Capacity of up to 800 individual operating panel users, each
having various security privileges.
Capacity of up to 800 individual card/key reader users, each
having various levels of access.
Control and recording of employee access to workplace
areas.
Recording of security-related activities.
Ability to send messages to up to 8 users.
The GTalarm2 module –the brains of your security system –is a
powerful microcomputer that manages every function of your security
system. All information about your site’s security is stored in this unit or
in the server.
Features of the module GTalarm2
Communication via SIA IP DC09 protocol
6 on-board zones. Input EOL/NO/NC and Tamper
Tamper supervision available, ensuring product is always secure
Built-in access control features
Automatic Daylight Savings Time feature
I/O1 and I/O2 can be used as a 2-wire smoke input
4 Analog inputs (pull up 5.1K) 0-10V
2 Analog Input/ Output , 0-10V , 0-20mA
3 Digital Inputs/Outputs 3.3V , 20mA,
Wiegand interface for Keypad and RFID card reader
4 PGM outputs 24V/1000mA. Open Drain.
Digital expansion module BUS.
In-field firmware upgrade via USB, SERA, Cloud Remote
Service
Events log buffer. 2048 events
Program remote controls using the master or installer codes
Up to 800 users remote controls with mob phone,
Up to 800 users remote controls with iButton or RFID keycard
Up to 800 user code. To control with Wiegand keyboard.
Built-in-real-time clock backup battery
Unlimited control via SMS.
The meaning of icons in the manual:
Contents
1.1 General view of the module.............................................................................................................................................................................3
1.2 Meaning of LEDs and contacts........................................................................................................................................................................3
1.3 First steps to prepare GTalarm2 module and Sera2 software..........................................................................................................................3
2Power supply, Battery Wiring..................................................................................................................................................................................4
3Application examples..............................................................................................................................................................................................5
3.1 Home security system.....................................................................................................................................................................................5
4System Monitoring and Remote Cloud Service.......................................................................................................................................................5
4.1 Monitoring, control via mobile phone, web browser. ARM/DISARM via mobile app. ........................................................................................6
4.2 Monitoring via SERA2 software. Zone status...................................................................................................................................................6
4.3 Reporting to the central monitoring station......................................................................................................................................................8
4.4 Local alarm .....................................................................................................................................................................................................8
4.5 Alarm, remote monitoring system....................................................................................................................................................................8
5Inputs. Zones..........................................................................................................................................................................................................9
5.1 NC, NO, EOL detectors wiring.........................................................................................................................................................................9
5.2 NC, NO, EOL detectors programming...........................................................................................................................................................10
5.3 Smoke detector Wiring..................................................................................................................................................................................12
5.4 Smoke detectors programming. ....................................................................................................................................................................12
6Outputs. Wiring & Programming............................................................................................................................................................................12
7Arming/ disarming, system control methods..........................................................................................................................................................15
8Wiegand Keypad & RFID Card Reader. Wiring & Programming............................................................................................................................17
9iButton keys. Wiring & Programming.....................................................................................................................................................................18
9.1 Enter iButton keys with Sera2 software.........................................................................................................................................................18
9.2 Enter iButton keys by sending SMS message...............................................................................................................................................18
9.3 ARM/DISARM with mobile phone..................................................................................................................................................................18
10 DISARM /ARM/SLEEP/STAY the security system ................................................................................................................................................19
11 System Fault/ Troubles Programming...................................................................................................................................................................20
12 Custom SMS Text.................................................................................................................................................................................................21
13 Reporting SMS&Dial in Case of Alarm Events ......................................................................................................................................................21
14 Reporting to the user‘s mobile phone....................................................................................................................................................................22
15 Reporting to the Central Monitoring Station...........................................................................................................................................................23
15.1.1 GPRS/ IP/ TCP/ UDP details programming .........................................................................................................................................23
15.1.2 Central Monitoring Station details programming ..................................................................................................................................23
16 General system options programming...................................................................................................................................................................24
17 RT Testing & Monitoring. Hardware......................................................................................................................................................................26
18 RT Testing & Monitoring Security Alarm Panel/ Access........................................................................................................................................27
19 Event Summary (Events)......................................................................................................................................................................................28
20 Software updates..................................................................................................................................................................................................28
21 Recommendations to the installer.........................................................................................................................................................................28
21.1 Glass break, shock sensors ..........................................................................................................................................................................28
21.2 Smoke, CO Detectors ...................................................................................................................................................................................30
22 Warning! The limitations of this alarm system. ......................................................................................................................................................30