Sharp KC-A60E User manual

R
Device of this mark is a trademark
of Sharp Corporation.
“Plasmacluster” and “Device of a cluster of
grapes” are registered trademarks of Sharp
Corporation in Japan, USA and elsewhere.
“High-Density 7000” is a trademark of
Sharp Corporation.
KC-A60E
KC-A50E
KC-A40E
Free standing type
Jenis berdiri sendiri
AIR PURIFIER
with Humidifying Function
OPERATION MANUAL
PEMBERSIH UDARA
dengan Fungsi Pelembapan
BUKU PANDUAN OPERASI
加湿空气净化器
使用说明书
ENGLISHMALAYSIA
直立式
中文
* The number in this technology mark indicates an
approximate number of ions supplied into air of 1 cm3,
which is measured around the center of a room with
the “high-density plasmacluser 7000” applicable floor
area (at 1.2 m height above the floor) at the maximum
wind volume in humidifying & air purifying mode, or
in air purifying mode, when a humidifier/air purifier or
an air purifier using the high-density plasmacluster
ion evolving device is placed close to a wall.
This product is equipped with a device corresponding to
this capacity.
KC-A60EA50EA40E-en.indd1 2011/05/1714:46:51

NOTE
The air purier draws in room air from the air intake, passes the air through a
Pre-Filter, a Washable Deodorizing Filter and a HEPA Filter inside of the unit, then
discharges the air through the air outlet. The HEPA Filter can remove 99.97% of dust
particles as small as 0.3 microns that pass through the lter and also helps absorb
odours.
The Washable Deodorizing Filter gradually absorbs odours as they pass through the
lter.
Some odours absorbed by the lters may break down over time, resulting in additional
odour. Depending on the usage environment, especially when the product is used in
extreme environments (significantly more severe than normal household use), this
odour may become strong in a shorter period than expected. If the odour persists, the
lters should be replaced.
• The air purier is designed to remove air-suspended dust and odour, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke). If the source of the odour still exists, the
air purier may not completely remove the odour.
(Common illustration has used “KC-A60E”.)
Please read before operating your new Air Purier
Pre-Filter
Deodorizing Filter
HEPA Filter
KC-A60E_A50E_A40E.indd 2 11.5.11 2:41:34 PM

E-1
ENGLISH
(Common illustration has used “KC-A60E”.)
ENGLISH
Thank you for purchasing this SHARP Air
Purifier. Please read this manual carefully
before using the air purier.
After reading, keep the manual in a conven-
ient location for future reference.
FEATURES CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
...E-2
• WARNING
• CAUTIONS CONCERNING OPERATION
• INSTALLATION GUIDELINES
• FILTER GUIDELINES
PART NAMES.............................................E-4
• FRONT / BACK
• MAIN UNIT DISPLAY
• ILLUSTRATIVE DIAGRAM
PREPARATION.............................................E-6
• FILTER INSTALLATION
• REFILLING THE WATER TANK
OPERATION...............................................E-8
• CLEAN AIR & HUMIDIFY
• CLEAN AIR
• CLEAN ION SHOWER
• FAN SPEED
• PLASMACLUSTER ION ON/OFF
USEFUL FUNCTION...............................E-10
• LIGHTS CONTROL
• CHILD LOCK
• SOUND INDICATOR SETTING
• ADJUSTMENT OF SENSOR
DETECTION SENSITIVITY
CARE AND MAINTENANCE .................E-11
• FILTER INDICATOR
• CARE INDEX
• HUMIDIFYING DISINSTALLATION
• WATER TANK
• HUMIDIFYING FILTER
• HUMIDIFYING TRAY AND COVER
• BACK PANEL
• DEODORIZING FILTER
• UNIT
• FILTER REPLACEMENT
TROUBLESHOOTING............................E-16
SPECIFICATIONS....................................E-19
Unique Combination of Air Treatment
Technologies
Triple Filtration System + Plasmacluster
+ Humidication
TRAPS DUST*
Washable pre-filter traps dust and other
large airborne particles.
DECREASES ODOURS
Washable deodorizing lter absorbs many
common household odours.
REDUCES POLLEN & MOLD*
HEPA filter traps 99.97% of particles as
small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to the
way nature cleans the environment by
emitting a balance of positive and negative
ions.
HUMIDIFIES
Runs up to 10 hours per lling.**
*When air is drawn through the filter sys-
tem.
**Room size:
up to 48 m2 (KC-A60E)
up to 38 m2 (KC-A50E)
up to 26 m2 (KC-A40E)
Sensor Technology continuously monitors
air quality, and automatically adjusting op-
eration based on detected air purity and
humidity.
KC-A60E_A50E_A40E.indd 1 11.5.11 2:41:34 PM

E-2
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the
following:
WARNING – To reduce the risk of electrical shock, re or injury to persons:
• Read all instructions before using the unit.
• Use only a 220~240 volt outlet.
•Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet
is loosened.
• Periodically remove dust from the plug.
• Do not insert ngers or foreign objects into the air intake or air outlet.
•When removing the power plug, always hold the plug and never pull on the cord.
Electrical shock and/or re from a short circuit may result.
•Do not damage the power cord by caster when moving the main unit.
(It may cause electric shock, heat generation or re.)
•Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
•When relling the Water Tank, cleaning the unit, or when the unit is not in use, be sure to unplug
the unit. Electrical shock and/or re from a short circuit may result
•If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a
Sharp authorized Service Centre or similarly qualied person in order to avoid a hazard.
• Only a Sharp Authorized Service Centre should service this air purier. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet,
such as a bathroom.
• Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior.
• When carrying the unit, remove the Water Tank and Humidifying Tray rst and hold the unit by han-
dles on both sides.
• Do not drink the water in the Humidifying Tray or Water Tank.
• Change the water in the Water Tank daily with fresh tap water and regularly clean the Water Tank
and Humidifying Tray. (See E-12 and E-13). When unit is not in use, dispose of the water in the
Water Tank and Humidifying Tray. Leaving water in the Water Tank and/or Humidifying Tray may
result in mold, bacteria, and bad odours.
In rare cases, this bacteria may cause harmful physical effects.
• This appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-
pervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
NOTE – Radio or TV Interference
If this air purier should cause interference to radio or television reception, try to correct the interfer-
ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation distance between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-
nected.
• Consult the dealer or an experienced radio/TV technician for help.
KC-A60E_A50E_A40E.indd 2 11.5.11 2:41:35 PM

E-3
ENGLISH
CAUTIONS CONCERNING OPERATION
• Do not block the intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters, or where it may come into
contact with steam.
• Always operate the unit in an upright position.
• Hold the unit by using the handles on both sides when moving.
Do not move when the unit is in operation.
• Do not move or change the direction of the main unit while dragging the casters.
• Lift it up and move such as a tatami mat, a oor which gets damaged easily, an uneven place, and
thick-poled carpet.
• When moving by the caster, move it slowly to horizontal direction.
• When moving, make sure to stop operation and remove the water tank and Humidifying Tray by
holding the side handle of the unit.
• When remove the water tank, be careful not to get your nger caught in.
• Do not operate the unit without the lters, Water Tank, and Humidifying Tray properly
installed.
• Do not wash and reuse the HEPA lter.
Not only does it not improve lter performance, it may cause electric shock or malfunction.
• Clean the exterior with a soft cloth only.
Do not use volatile uids and/or detergents.
The unit surface may be damaged or cracked.
In addition, the sensors may malfunction as a result.
• Frequency of maintenance required (descaling) will depend on the hardness or the
impurities of the water that you use; the harder the water the more often descaling will be
necessary.
• Keep the unit away from water.
INSTALLATION GUIDELINES
•When using the unit, place at least 2m away from equipment utilizing electric waves such
as televisions or radios to avoid electrical interference.
• Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
• Avoid use in locations where furniture, fabrics or other items may come in contact with and
restrict the air intake and/or air outlet.
• Avoid use in locations where the unit is exposed to condensation or drastic temperature
changes. Appropriate conditions are when room temperature is between 5 – 35 ºC.
• Place on a stable surface with sufcient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly.
Place the unit on an even surface to avoid water leakage from the Water Tank and/or Humidifying
Tray.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack or the sensor may malfunction as a result.
• Place the unit about 30 cm(1 ft) away from the wall in order to ensure proper airow.
The wall directly behind the air outlet may become dirty over time. When using the unit for an ex-
tended period of time in the same location, periodically clean the wall and protect the wall with a
vinyl sheet, etc. to prevent the wall from becoming dirty.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the lters.
KC-A60E_A50E_A40E.indd 3 11.5.11 2:41:35 PM

E-4
PART NAMES
FRONT / BACK
1 Main Unit Display (Ref.E-5)
2Front Monitor
3Main Unit
1
3
1 Air Outlet 6 Float
2 Handle (2 Locations) 7 Humidifying Tray
3 Sensor (Internal)
•Dust Senser
•Temperture / Humidity Senser
•Odour Senser
(KC-A60E•KC-A50E ONLY)
8 Caster (4 Locations)
9 HEPA Filter (white)
10 Deodorizing Filter (black)
11 Back Panel (Pre-Filter)
12 Air Inlet
4Water Tank 13 Power Cord / Plug
5 Humidifying Filter
1
2
3
4
5
7
2
8
9
10
11
1 POWER ON Button
aCLEAN AIR MODE Button /INDICATOR LIGHT (green)
bCLEAN AIR & HUMIDIFY MODE Button / INDICATOR LIGHT (green)
cCLEAN ION SHOWER MODE Button / INDICATOR LIGHT (green)
2 LIGHT CONTROL Button 5 CHILD-LOCK Button /
INDICATOR LIGHT (green)
3Plasmacluster Ion ON / OFF Button /
INDICATOR LIGHT (green)
6 Plasmacluster Sign
4FILTER RESET Button /
INDICATOR LIGHT (red)
7FAN SPEED Button /
INDICATOR LIGHT (green)
8 POWER OFF Button
6
13
(Shape of plug depends on country.)
12
INCLUDED
• Operation manual
• Slipper ×4
KC-A60E_A50E_A40E.indd 4 11.5.11 2:41:35 PM

E-5
ENGLISH
MAIN UNIT DISPLAY
1 POWER ON Button
aCLEAN AIR MODE Button /INDICATOR LIGHT (green)
bCLEAN AIR & HUMIDIFY MODE Button / INDICATOR LIGHT (green)
cCLEAN ION SHOWER MODE Button / INDICATOR LIGHT (green)
2 LIGHT CONTROL Button 5 CHILD-LOCK Button /
INDICATOR LIGHT (green)
3Plasmacluster Ion ON / OFF Button /
INDICATOR LIGHT (green)
6 Plasmacluster Sign
4FILTER RESET Button /
INDICATOR LIGHT (red)
7FAN SPEED Button /
INDICATOR LIGHT (green)
8 POWER OFF Button
23
45
1
ILLSTRARATIVE DIAGRAM
green
off
red
(Flash
ing)
Humidity ON
Humidity OFF
need to supply water
green
red
Clean
Impure
a
Humidity Monitor
Indicates approximate humidity level
in the room.
Humidity setting cannot be adjusted.
Humidify Light
Odour Monitor*
Indicates the odour intensity of the
room in 3 stages colours.
green red
Faint Strong
Dust Moniter
Indicates the air purity of the room
in 5 stages colours.
* KC-A60E, KC-A50E ONLY
bc
6 7 8
KC-A60E_A50E_A40E.indd 5 11.5.11 2:41:36 PM

1
2
E-6
1
Remove the Back Panel.
PREPARATION
FILTER INSTALLATION
2
Remove the Filters from the
plastic bag.
3
Install the Filters in the correct
order as shown.
4
Install the Back Panel.
5
Fill in the usage start date on the
Date Label.
HEPA lter (White)
Deodorizing lter (Black)
Be sure to remove the power
plug from the wall outlet.
Click
HEPA lter (White) Deodorizing lter (Black)
KC-A60E_A50E_A40E.indd 6 11.5.11 2:41:38 PM

1
2
3
1
2
MAX
E-7
ENGLISH
3
Install the Water Tank.
CAUTION
REFILLING THE WATER TANK
1
Remove the Water Tank.
2
Fill the Water Tank with tap water.
•
Check to see that there is no water leaking.
• Be sure to wipe off any excess water on
the outside of the Water Tank.
• When carrying the Water Tank, hold it
with both hands so that the Water Tank
opening is facing up.
When using the Clean Air & Humidify Mode, or the Clean ION Shower Mode.
• Do not expose the unit to water. Short circuit and/or electrical shock may occur as a result.
• Do not use hot water (40 ºC), chemical agents, aromatic substances, dirty water, or other damag-
ing substances, deformation and/or malfunction may occur.
• Use only fresh tap water. Use of other water sources may promote the growth of mold, fungus and/
or bacteria.
Tighten
CAUTION
Click
KC-A60E_A50E_A40E.indd 7 11.5.11 2:41:38 PM

E-8
OPERATION
STOP
About Automatic Humidify Mode
The Temperature/Humidity sensors automatically detect and adjust
humidity according to changes in room temperature. Depending on
the size and humidity of the room, humidity may not reach 55~65 %.
In such cases, it is recommended that CLEAN AIR & HUMIDIFY/
MAX MODE be used.
CLEAN AIR & HUMIDIFY
Temperature Humidity
~18 ºC 65 %
18 ºC~24 ºC 60 %
24 ºC~ 55 %
Using to quickly clean the air, reduce odours and to humidify.
• Select the desired fan speed.(Ref. E-9)
• Unless the power cord has been un-
plugged, the operations starts in the pre-
vious mode it was operated in.
NOTE
• Fill the Water Tank.(Ref. E-7)
• When the Water Tank is empty, the unit will operation “CLEAN AIR MODE”and is
ashing(red).
START
STOP
CLEAN AIR
Using when additinal humidity is not required.
• Select the desired fan speed.(Ref. E-9)
• Unless the power cord has been un-
plugged, the operations starts in the pre-
vious mode it was operated in.
START
KC-A60E_A50E_A40E.indd 8 11.5.11 2:41:39 PM
This manual suits for next models
2
Table of contents
Languages:
Other Sharp Air Cleaner manuals

Sharp
Sharp KC-G60SA User manual

Sharp
Sharp IG-BC2UB User manual

Sharp
Sharp FP-A28UW User manual

Sharp
Sharp FU-28H-A User manual

Sharp
Sharp FZ-28SEF User manual

Sharp
Sharp UA-KIL80E User manual

Sharp
Sharp EH-HS41 User manual

Sharp
Sharp KI-A60Y User manual

Sharp
Sharp IG-CM1A User manual

Sharp
Sharp FU-S25E User manual

Sharp
Sharp KI-N50TA User manual

Sharp
Sharp IG-DM1Y User manual

Sharp
Sharp Plasmacluster FP-P30U User manual

Sharp
Sharp UA-HG50E User manual

Sharp
Sharp IG-CL15A User manual

Sharp
Sharp KC-G60Y User manual

Sharp
Sharp FP-J50J-W User manual

Sharp
Sharp FU-40SE-K User manual

Sharp
Sharp FP-J80E User manual

Sharp
Sharp Plasmacluster FP-A28C User manual





















