Sharp IG-NX2B User manual

“Plasmacluster” and “Device of a cluster
of grapes” are trademarks of Sharp
Corporation.
* 1 The number on this technical mark
indicates more than 50,000 ions
supplied into air of 1 cm3, which is
measured near the center of space
(0.5 m height from floor) when the air
volume is “MED” by placing the
product in an appropriate place such
as a cup holder beside the driver's
seat.
IG-NX2B
IG-NX2Y
PLASMACLUSTER ION
GENERATOR OPERATION
MANUAL
ENGLISH
เครื่องพนอนุภาค
พลาสมาคลัสเตอร
คูมือการใชงาน
ภาษาไทย
PETUNJUK
PENGOPERASIAN UNIT
PENGHASIL ION
PLASMACLUSTER
INDONESIA
01_IG-NX2B_IG-NX2Y-EN.indd 101_IG-NX2B_IG-NX2Y-EN.indd 1 2/6/2564 BE 20:522/6/2564 BE 20:52

ENGLISH
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS............................. 1
PART NAMES...................................................................... 4
INSTALLATION GUIDANCE ............................................... 6
OPERATION........................................................................ 8
CLEANING AND MAINTENANCE..................................... 10
REPLACEMENT................................................................ 14
TROUBLESHOOTING ...................................................... 15
SPECIFICATIONS............................................................. 17
Thank you for purchasing this SHARP Plasmacluster Ion Generator.
Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.
• While the product can remove suspended viruses and other
contaminants, it cannot create a completely sterile environment.
SHARP does not guarantee its ability to prevent microbial
infection.
• To enable stable emission of high-density Plasmacluster ions,
the Plasmacluster Ion Generating Unit mounted in the product
will need to be replaced periodically*.
• The product is designed for ordinary passenger cars with DC 12
V batteries. It cannot be used in vehicles with DC 24 V batteries
(buses, trucks, etc.).
* Replacement is required approximately every 6 years (17,500 hours) when
operated 8 hours a day. the product will stop operating after about 6 years
and 6 months (19,000 hours) if the Plasmacluster Ion Generating Unit is
not replaced.
01_IG-NX2B_IG-NX2Y-EN.indd 201_IG-NX2B_IG-NX2Y-EN.indd 2 2/6/2564 BE 20:522/6/2564 BE 20:52

EN-1
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
Please read these instructions carefully before using this product.
When using electrical appliances, basic safety precautions should
be followed, including the following:
WARNING - To reduce the risk of electric shock, fire or injury :
• Do not operate switches while driving. (Doing so could lead to
accidents.)
• Do not install the product in places where it could hamper visibility
to the front, driving operations, or in places where it could be
dangerous to passengers. (Doing so could lead to accidents or
injury.)
• Do not put in places exposed to direct sunlight. (Doing so could
cause warping or malfunction.)
• This product is designed exclusively for use in vehicles with 12 V
batteries. Do not use it in other vehicles. Do not use the product in
large trucks, buses or other vehicles with 24 V batteries. (Doing so
could lead to fire or electric shock.)
• Do not damage or modify the cord. Also, do not use the cord if it is
damaged. (The damaged section could cause short-circuiting and
the cord could melt, leading to fire.) If the cord is damaged, contact
your store of purchase or SHARP authorized service center.
• Do not pull on the cord when unplugging the Car Adapter or the
Micro USB Plug. (Doing so could damage the cord, leading to fire
or electric shock.)
• Do not plug in or unplug the Car Adapter or the Micro USB Plug
with wet hands. (Doing so could cause electric shock.)
• When transporting, be careful not to drop the product or subject it
to shocks. (Doing so could cause injury or damage.)
If the product should drop or be damaged, contact your store of
purchase or SHARP authorized service center.
Continued usage of damaged product could lead to fire or electric
shock.
01_IG-NX2B_IG-NX2Y-EN.indd EN-101_IG-NX2B_IG-NX2Y-EN.indd EN-1 2/6/2564 BE 20:522/6/2564 BE 20:52

EN-2
• Do not modify the product. Also, no one other than an authorized
repairman should take apart or repair the product. (Doing so could
lead to fire, electric shock or injury.) Contact your store of purchase
or SHARP authorized service center for repairs.
• Do not spill beverages or drop cigarette ashes, metal objects,
easily burnable objects, etc., into the product through the Air Outlet
or Air Inlet. Be particularly careful if there are small children in your
family. If water or foreign substances should get inside the product,
unplug the Car Adapter from the accessory socket. (Continued
usage could lead to fire or electric shock.) Contact your store of
purchase or SHARP authorized service center.
• Do not wipe the product with oils, alcohol, benzine or thinners, or
spray hairspray or insecticides on the product. If such substances
should get on the product, wipe them off immediately. (Such
substances could lead to cracking or electric shock or could catch
fire.)
• Do not place the product in a place where it is exposed to oil
smoke or moisture such as kitchen counter or humidifying device.
(Doing so could lead to electric shock.)
• Do not place the product near heating equipment such as the
outlet of hot-air type heater. (Doing so could cause warping or
malfunction.)
• Use the Car Adapter designed exclusively for this product, and
insert the Car Adapter securely all the way in until it stops. (If the
Car Adapter is not inserted securely until it stops, it could heat up,
deforming the accessory socket, and this could lead to fire.)
• Be sure to unplug the Car Adapter from the accessory socket when
cleaning. (Failure to do so could cause electric shock or injury.)
• Be sure to unplug the Car Adapter from the accessory socket when
not in use for long periods of time. (Failure to do so could lead to
electric shock or fire caused by short-circuiting.)
• If the accessory socket is integrated into the ashtray, be sure that
cigarettes are completely extinguished before using the product.
• When leaving the vehicle, unplug the Car Adapter and close the
ashtray’s lid. (Failure to do so could lead to fire caused by the
smoldering cigarettes.)
01_IG-NX2B_IG-NX2Y-EN.indd EN-201_IG-NX2B_IG-NX2Y-EN.indd EN-2 2/6/2564 BE 20:522/6/2564 BE 20:52

EN-3
ENGLISH
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.
CAUTIONS CONCERNING OPERATION :
• Do not touch the metal parts of the Car Adapter (or of the
accessory socket).
(The metal parts of the Car Adapter could be hot directly after the
car is stopped, and could cause burns if touched.)
• Do not use the product in external cup holders, on shaky or
non-level surfaces or in other unstable places. (The product could
fall, resulting in injury or damage.)
• Move the product out of the car when using room fumigating type
insecticides or deodorizers. If not, the chemicals could get inside
the product and later be ejected from the Air Outlet, possibly
harming your health.
• If the product risks falling out of the cup holder (when driving on
rough roads, over bumps, etc.), either slow down or remove the
product from the cup holder beforehand. (Failure to do so could
cause injury or damage to the product.)
• Do not use silicone-based items* near the product.
The fluororesin or silicone could get stuck inside the product,
preventing it from producing Plasmacluster ions.
If this happens, remove the dust from the electrode section of the
Plasmacluster Ion Generating Unit. (Page 13)
* Hair care items (split end coatings, hair mousses, hair treatments, etc.),
cosmetics, antiperspirants, antistatic agents, waterproofing sprays, polishes,
glass cleaners, chemical-impregnated clothes, wax, etc.
01_IG-NX2B_IG-NX2Y-EN.indd EN-301_IG-NX2B_IG-NX2Y-EN.indd EN-3 2/6/2564 BE 20:522/6/2564 BE 20:52

EN-4
PART NAMES
Note
NOTE
• Please use the official Car Adapter and power cord.
(Failure to do so could lead to fire / electric shock / failure)
1
2
3
4
5
13
14
15
16
7
9
8
10
6
11
12
01_IG-NX2B_IG-NX2Y-EN.indd EN-401_IG-NX2B_IG-NX2Y-EN.indd EN-4 2/6/2564 BE 20:522/6/2564 BE 20:52

EN-5
ENGLISH
1Main Unit
2Air Outlet
3Operation Button
(Page 8)
4Operation Lamp
(Blue, Purple)
5Unit Replacing Lamp
(Red) (Page 9)
6Power Supply Port
7Unit* Holder
8Plasmacluster Ion
Generating Unit*
9Unit* Cleaning Brush
10 Main Unit Cover
11 PM10 Filter
12 Filter Cover
13 Micro USB Plug
14 Cord (length 1.5 m)
15
USB Plug
• Do not use with voltages
other than the rated
voltage of DC 5 V.
16 Car Adapter
(with 2 ports)
* The Unit refers to Plasmacluster Ion
Generating Unit. (The same as
below.)
01_IG-NX2B_IG-NX2Y-EN.indd EN-501_IG-NX2B_IG-NX2Y-EN.indd EN-5 2/6/2564 BE 20:532/6/2564 BE 20:53

EN-6
INSTALLATION GUIDANCE
Insert the Car Adapter into the accessory socket and
connect the USB plug to the Car Adapter.
• You can use the product by inserting the
included USB cable into USB connector of
PC, etc.
NOTE
• Be sure to remove any dirt from the accessory socket. Failure to
do so could cause faultily contact or fire.
• The Car Adapter (accessory) for the product has 2 USB ports.
It is possible to connect another equipment of 1.5 A or lower
while the product is connected. However, in this case, the normal
operation of the additional equipment is not guaranteed.
• The Car Adapter and/or connecting section could be hot while in
use and/or right after use.
01_IG-NX2B_IG-NX2Y-EN.indd EN-601_IG-NX2B_IG-NX2Y-EN.indd EN-6 2/6/2564 BE 20:532/6/2564 BE 20:53

EN-7
ENGLISH
Cautions on wiring the Car Adapter
• Do not let the cord touch or get caught in the seat rails, shift lever
or other moving parts.
• Wire in such a way that the cord does not get in the way of the
driver.
• Consider the movement of the seats (forward / backward, swiveling
or reclining) when wiring.
• Do not bend the cord extremely or compress it.
Cautions on installation
• Separate the product from
electronic key of vehicle by 30 cm
or more. Otherwise, it may
interfere with electronic wave of
product and the electronic key may
not be recognized.
• Be sure to place in a stable
location. (Do not put in a external
cup holder or other unstable
place.)
• Do not obstruct the air inlet or outlet.
• Keep the product away from the vehicle’s in-glass antenna. Failure
to do so could cause interference on the radio.
• If there should be interference on a TV or radio located in the same
car, or if an atomic clock in the car should not display the time
properly, move the product away from the TV, radio, atomic clock,
etc.
• If the product is installed directly in front of the car climate control’s
outlets, the product could get hot when the climate control is
operating in the heating mode.
• The product could get scratched by the vibrations of the vehicle,
etc.
• It might be impossible to use for some types of cars.
01_IG-NX2B_IG-NX2Y-EN.indd EN-701_IG-NX2B_IG-NX2Y-EN.indd EN-7 2/6/2564 BE 20:532/6/2564 BE 20:53

EN-8
OPERATION
SELECT MODE
LOW MED TURBO
QUICK CLEANOFF
LOW Release high-density Plasmacluster
ions quietly.
MED Release Plasmacluster ions
approximately 2 times as much as
“LOW” at standard air flow.
TURBO Release Plasmacluster ions
approximately 3.6 times as much as
“LOW” at a strong air flow.
QUICK CLEAN If you want to remove odors quickly.
Releases Plasmacluster ions with
TURBO mode for 25 minutes, After that,
the mode is switches “MED”.
• After smoking
• After eating in a vehicle
• When you are conscious about odor of air
conditioner
01_IG-NX2B_IG-NX2Y-EN.indd EN-801_IG-NX2B_IG-NX2Y-EN.indd EN-8 2/6/2564 BE 20:532/6/2564 BE 20:53
This manual suits for next models
1
Table of contents
Languages:
Other Sharp Air Cleaner manuals

Sharp
Sharp IG-CL15A User manual

Sharp
Sharp FU-60SE-TA User manual

Sharp
Sharp KC-F32EU User manual

Sharp
Sharp FU-A28TA User manual

Sharp
Sharp KC-G60EU User manual

Sharp
Sharp FX-J80U Instruction Manual

Sharp
Sharp Plasmacluster FP-P30U User manual

Sharp
Sharp QNET FP-E50E User manual

Sharp
Sharp IG-BC2A User manual

Sharp
Sharp FP-F40A User manual

Sharp
Sharp KI-L80 User manual

Sharp
Sharp IG-A10EK-W Manual

Sharp
Sharp FP-J50J-W User manual

Sharp
Sharp FP-H50A User manual

Sharp
Sharp FP-A80M User manual

Sharp
Sharp UA-HD60E User manual

Sharp
Sharp FU-28H User manual

Sharp
Sharp KI-G75EU User manual

Sharp
Sharp FP-J30E User manual

Sharp
Sharp FU-W40A User manual