Sharp FP-H50A User manual

ENGLISH
中文
FP-H50A
R
AIR PURIFIER
OPERATION MANUAL
空氣清新機
使用說明書
Free standing type
直立型號
“Plasmacluster” and “Device of a cluster of grapes” are
trademarks of Sharp Corporation.
*The number in this technology mark indicates an
approximate number of ions supplied into air of 1 cm3,
which is measured around the center of a room with
the “high-density plasmacluster 7000” applicable oor
area (at 1.2 m height above the oor) when the device
is placed close to a wall at the MED mode setting.
OM_FP-H50A.indd 1 2017/04/05 10:01:08

NOTE
The air purier draws in room air from the air intake, passes the air through a Pre-
Filter, a Active Carbon Deodorizing Filter and a HEPA Filter inside of the unit, then
discharges the air through the air outlet. The HEPA Filter can remove 99.97% of dust
particles as small as 0.3 microns that pass through the lter.
The Active Carbon Deodorizing Filter gradually absorbs odors as they pass through
the lter.
Some odors absorbed by the lters may break down over time, resulting in additional
odor. Depending on the usage environment, especially when the product is used in
extreme environments (significantly more severe than normal household use), this
odor may become strong in a shorter period than expected. If the odor persists, the
lters should be replaced.
• The air purier is designed to remove air-suspended dust and odor, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke).
Please read before operating your new Air Purier
HEPA Filter
Active Carbon
Deodorizing Filter
Back Panel
(Pre-Filter)
OM_FP-H50A.indd 2 2017/04/05 10:01:09

ENGLISH
E-1
ENGLISH
Thank you for purchasing the SHARP
Air Purier. Please read this manual carefully.
Before using this product, be sure to read the
section: “Important Safety Instructions.”
After reading this manual, keep it in a
convenient location for future reference.
For your reference, we recommend to keep
this manual in the place where you can read
at any time.
IMPORTANT SAFETY INSTRUCTIONS
..... E-2
PARTS NAME...............................................E-4
FILTER INSTALLATION ............................. E-5
OPERATION .................................................E-6
CARE AND MAINTENANCE ..................... E-8
TROUBLESHOOTING ..............................E-10
SPECIFICATIONS...................................... E-11
CONTENTS
FEATURES
Unique Combination of Air Treatment
Technologies
Triple Filtration System + Plasmacluster
Ions
TRAPS DUST*
Pre-lter traps dust and other large
airborne particles.
REDUCES ODORS
Active Carbon Deodorizing lter absorbs
many common household odors.
REDUCES POLLEN & MOLD*
HEPA lter traps 99.97% of particles as
small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to the
way nature cleans the environment by
emitting a balance of positive and negative
ions.
*When air is drawn through the lter
system.
Sensor Technology continuously monitors
air quality, and automatically adjusting
airow based on detected air purity.
OM_FP-H50A.indd 1 2017/04/05 10:01:10

E-2
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed,
including the following:
WARNING - To reduce the risk of electric shock, re or injury to persons:
• Read all instructions before using the unit.
• Use only a 220 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the
wall outlet is loosened.
• Periodically remove dust from the power plug.
• Do not insert ngers or foreign objects into the intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electric shock and/or re from short circuit may occur as a result.
• Be careful not to damage the power cord, it may cause electric shock, excess heat or
res.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not
using the unit.
Electric shock from bad insulation and/or re from short circuit may occur as a result.
•When cleaning the unit, or when the unit is not in use, be sure to unplug the unit. Electric
shock and/or re from a short circuit may result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service
agent, Sharp Authorized Service Centre or similarly qualified person in order to
avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue,
incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity
conditions, such as a bathroom.
• Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
• Only a Sharp Authorized Service Centre should service this air purifier. Contact the
nearest Service Centre for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
NOTE - Radio or TV Interference
If this air purier should cause interference to radio or television reception, try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
OM_FP-H50A.indd 2 2017/04/05 10:01:10

ENGLISH
E-3
CAUTIONS CONCERNING OPERATION
• Do not block the air intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may
come into contact with steam.
• Do not lay the unit down when using.
• Always hold the handle on the back of the unit when moving it.
• Do not use without the lters installed inside the unit.
• Do not wash and reuse the HEPA lter and the Active Carbon Deodorizing lter.
Not only does it not improve lter performance, it may cause electric shock or malfunction.
INSTALLATION GUIDELINES
•When using the unit, place it away from equipment utilizing electric waves such as
televisions or radios to avoid electrical interference.
• Avoid using in locations where furniture, fabrics or other items may come in
contact with and restrict the air intake and/or air outlet.
• Avoid using in locations where the unit is exposed to condensation or drastic
temperature changes. Appropriate condition is at room temperature 0 – 35 ºC.
• Place on a stable surface with sufcient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack as a result.
•Place the unit about 30 cm(1 ft) away from the wall in order to ensure proper
airow.
The dust collecting performance will be the same even if using the unit 3cm away from
the wall, but place it as far as possible(30cm away recommended) because it may dirty
the wall or oor around.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the lter.
OM_FP-H50A.indd 3 2017/04/05 10:01:10

E-4
PARTS NAME
19
18
1Main Unit 10 Handle
2Air Outlet 11 Dust sensor/
Dust Sensor Filter
3OFF TIMER Button / OFF TIMER indicator Light (green)
LIGHT ON/OFF Button (Press 3 sec.) 12 HEPA Filter
4MODE Button / MODE Indicator Light (green)
Plasmacluster Ion ON/OFF Button(Press 3 sec.) 13 Active Carbon
Deodorizing Filter
5CLEAN ION SHOWER Button /
CLEAN ION SHOWER indicator Light (green)
14 Upper Tabs
15 Back Panel (Pre-Filter)
6POWER ON/OFF Button 16 Bottom Tabs
7ODOR Sensor 17 Power Cord
8DUST AND ODOR SIGN 18 Plug
9PLASMACLUSTER SIGN 19 Date Label
BACK
17
14
15
10
11
12
13
16
2
1
FRONT
PLASMACLUSTER SIGN
blue Plasmacluster ON
off Plasmacluster OFF
9
8
Clean
Impure
Red
Orange
Green
3 4 5 6
DUST AND ODOR SIGN
Indicates the air purity of the room
in 3 levels with color changes.
7
OM_FP-H50A.indd 4 2017/04/05 10:01:14

ENGLISH
E-5
FILTER INSTALLATION
To maintain the quality of the lter, it is installed in the main unit and packed in plastic
bag. Be sure to remove the lter from the plastic bag before using the unit.
1
Remove the Back Panel.
2Remove the plastic bag and
take out the Filter.
3
Place the Filter inside the main
unit.
Do not install the lter backwards or the
unit will not operate properly.
Upper Tabs
• Do not operate the unit without the lter.
Date Label
Pull Push
Push
Be sure to remove the power plug
from the wall outlet.
Starting Date Of Filters
. .. .
HEPA過濾網&
活性碳除臭過濾網
MODEL
FZ-F45SFA
HEPA Filter & Active Carbon
Deodorizing Filter
約10年
~10 years
The actual replacement period
depends on operation hours and
installation location. If dust or
odor cannot be removed easily,
please replace the filters.
4Replace the Back Panel to the
main unit.
5Fill in the usage start date on the
Date Label.
Use the date as a guide for the lter
replacement schedule.
Bottom Tabs
HEPA Filter
Active Carbon
Deodorizing Filter
OM_FP-H50A.indd 5 2017/04/05 10:01:20

E-6
OPERATION
AUTO SLEEP MED MAX
CLEAN AIR
START
• Select the desired fan speed.
• Unless the power cord has been unplugged,
the operation starts in the previous mode it
was operated in.
STOP
FAN SPEED
SLEEP
• The unit will operate very quietly, and the fan speed
is automatically switched depending on the amount of
impurities in the air.
DUST AND ODOR /PLASMACLUSTER SIGN go off
automatically.
Even though the indicator is off, Plasmacluster Ion is
released into air unless Plasmacluster Ion is turned off by
NOTE
AUTO
• The fan speed is automatically switched depending on the
amount of impurities in the air. The sensors detect impurities
for efcient air purcation.
Releases high-density Plasmacluster ions and discharges strong air ow for 60 minutes.
CLEAN ION SHOWER
START
• If Plasmacluster Ion is OFF, Plasmacluster Ion will not be
released.
• When the operation nishes, the unit will return to the prior
operation mode.
It is able to change the other mode or turn off during this
mode.
NOTE
OM_FP-H50A.indd 6 2017/04/05 10:01:37

ENGLISH
E-7
Light Control
Plasmacluster Ion ON/OFF
You can turn OFF the DUST AND ODOR /PLASMACLUSTER SIGN when they are lighting up.
● 2h ● 4h ● 8h CANCEL
ON
more than 3 sec.
OFF
• When the unit restarts its
operation, Light Control
resumes its setting set before
turning off.
• At Sleep Mode, Light Control
is available.
NOTE
When Plasmacluster Ion is ON, the PLASMACLUSTER SIGN will turn on. (blue)
(In operation)
ON OFF
ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
Set to “Low” if the DUST AND ODOR SIGN is constantly red to reduce sensitivity,
and set to “High” if the DUST AND ODOR SIGN is constantly green to increase sensitivity.
OFF TIMER
Select the time turning off the unit during operation. The unit automatically stops once the selected
time is reached.
• If the Power ON/OFF Button is
not pressed within 8 seconds of
adjusting sensor sensitivity, the
setting will be saved automatically.
• The sensor sensitivity setting
will be saved even if the unit is
unplugged.
NOTE
1
2
3
(with the unit OFF)
High
Standard
Low
more than 3 sec.
more than 3 sec. more than 3 sec.
more than 3 sec.
Select the
sensor detection
sensitivity.
OM_FP-H50A.indd 7 2017/04/05 10:01:47

E-8
CARE AND MAINTENANCE
Gently remove dust from the back panel by using a
vacuum cleaner attachment or similar tool.
BACK PANEL (Pre-lter)
To maintain optimum performance of this air purier, please clean the unit including the lter
periodically.
Be sure to disconnect the power cord from the wall outlet before performing any maintenance.
Back Panel
CAUTION
Back Panel
Do not apply excessive pressure, when scrubbing the back
panel.
NOTE How to clean hard to remove dirt
1. Add a small amount of kitchen detergent to water and soak
for about 10 minutes.
2. Rinse off the kitchen detergent with clean water.
3. Completely dry the lter in a well-ventilated area.
FILTERS
Tag
HEPA Filter
Active Carbon Deodorizing Filter
CAUTION
Gently remove dust from HEPA Filter and Active Carbon Deodorizing
Filter with a vacuum cleaner attachment or similar tool.
Do not WASH in water and DRY in the sun.
The lters are fragile, be careful not to apply too much force.
• HEPA Filter
Apply the maintenance only on the side with the tag.
Do not clean the opposite side; otherwise, the lter will be
damaged.
• Active Carbon Deodorizing Filter
The maintenance can be applied to the both sides.
UNIT
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
•Do not use volatile uids
Benzine, paint thinner, polishing powder, etc., may damage the surface.
•Do not use detergents
Detergent ingredients may damage the unit.
CAUTION
OM_FP-H50A.indd 8 2017/04/05 10:01:52
Table of contents
Other Sharp Air Cleaner manuals

Sharp
Sharp FU-21SE User manual

Sharp
Sharp Plasmacluster KC-840E User manual

Sharp
Sharp KI-L80 User manual

Sharp
Sharp FP-J60TA User manual

Sharp
Sharp FP-F30A User manual

Sharp
Sharp KI-G75EU User manual

Sharp
Sharp UA-HG40E-T User manual

Sharp
Sharp UA-PM50E User manual

Sharp
Sharp IG-A10EU-W Manual

Sharp
Sharp Plasmacluster KC-850U User manual

Sharp
Sharp IG-A20EK-W Manual

Sharp
Sharp FX-S120 User manual

Sharp
Sharp UA-KCP100E User manual

Sharp
Sharp FP-JM30B User manual

Sharp
Sharp KC-D51R User manual

Sharp
Sharp KI-L80 Manual

Sharp
Sharp FP-J80E User manual

Sharp
Sharp Plasmacluster IG-A10J-B User manual

Sharp
Sharp IG-CL15B User manual

Sharp
Sharp FU-P60S-E User manual