Securacom SEC8 User manual

SEC8
Security System
User Manual
Securacom

2 P0031-LU-01.00
Contents
1.About your Alarm System .................................................................. 4
Introduction................................................................................................................ 4
About this Manual...................................................................................................... 4
Fire Detection............................................................................................................. 4
Monitoring .................................................................................................................. 4
Zones.......................................................................................................................... 5
Access Codes ............................................................................................................. 5
Remote Keypads........................................................................................................ 5
LED Keypad.......................................................................................................... 5
LCD Keypad ......................................................................................................... 6
LED Status Indicators.......................................................................................... 6
Function Keys ...................................................................................................... 7
Emergency Keys .................................................................................................. 7
2.Operating the Alarm System ............................................................. 8
Introduction................................................................................................................ 8
User Menus ................................................................................................................ 8
Before Arming the System......................................................................................... 9
Away Arm - A............................................................................................................. 9
Stay Arm 1 - S......................................................................................................... 10
Stay Arm 2 - 2* ..................................................................................................... 10
Stay Arm 3 - 3* ..................................................................................................... 10
Disarming the System ............................................................................................. 11
Bypassing Zones - B............................................................................................... 12
Walk Test - 11* ................................................................................................... 13
Test Bell & Outputs - 12*.................................................................................... 14
Do Test Call13* .............................................................................................. 15
View Event Log21*......................................................................................... 16
Log Event Codes and Descriptions ......................................................................... 17
Print Event Log22*......................................................................................... 20
Call UDL23*.................................................................................................... 21
Change Code81*............................................................................................ 22
Program Mode91* ......................................................................................... 22
Exit Menu99* ................................................................................................. 22

P0031-LU-01.00 3
3.User Programming Menu................................................................. 23
Introduction.............................................................................................................. 23
Text Entry (LCD Only) ............................................................................................... 24
Stay Arm Banner Text .............................................................................................. 25
Speech Dialler Telephone Numbers ....................................................................... 26
User Setup................................................................................................................ 27
User Access Code .............................................................................................. 27
User Type ........................................................................................................... 28
User Locked By .................................................................................................. 29
User Name ......................................................................................................... 31
Time and Date.......................................................................................................... 32
4.Touch-Tone Remote Control ............................................................ 33
Introduction.............................................................................................................. 33
Remote Control Menu ............................................................................................. 33
Remote Access ........................................................................................................ 33
Away Arm.................................................................................................................. 34
Stay Arm ................................................................................................................... 34
Disarm ...................................................................................................................... 34
Turn Remote Controlled Outputs On and Off.......................................................... 34
Record and Playback Speech Messages................................................................ 35
5.Fire Safety and System Maintenance ............................................ 36
Fire Safety ................................................................................................................ 36
Household Fire Safety Audit.............................................................................. 36
Fire Escape Planning ......................................................................................... 36
Fire Alarm Operation.......................................................................................... 37
System Maintenance............................................................................................... 37
6.Installation Information .................................................................. 38
Remote Keypads...................................................................................................... 38
Users......................................................................................................................... 38
Zones........................................................................................................................ 38
Installer Information ................................................................................................ 39
Alarm Receiving Centre Information ....................................................................... 39

4 P0031-LU-01.00
1. About your Alarm System
Introduction
Your alarm system consists of a control panel which is connected to the mains power supply,
one or more remote keypads and various detection devices that are wired back to the
control panel. The control panel will normally be installed out of sight in a utility room or
under stairs cupboard etc. The control panel houses the system’s electronics and stand-by
battery. There is normally no reason for anyone except an installer or service person to have
access to the control panel.
The remote keypad provides the user interface for the system and is used to send
commands to the system and to display the current system status via the various coloured
lights (LED’s) and/or LCD display. The remote keypad also provides audible feedback
annunciation of fault and alarm tones. Each remote keypad should be mounted in
convenient locations inside the protected premises, near to the points of entry and exit.
Please read this manual carefully and have your installer instruct you on your system’s
operation. Become familiar with the features that have been implemented on your system.
All users of this system should be equally instructed in its use.
About this Manual
This manual provides a thorough explanation of all system functions that are available to the
master user, including troubleshooting and programming user access codes in addition to
performing basic system functions. Standard users of the system will not need to know all of
this information. The section “Operating your Alarm System” explains general operating
procedures for arming and disarming the system. The remaining sections of the manual are
reserved for more detailed system information.
Fire Detection
This equipment is capable of monitoring fire detection devices such as smoke detectors and
providing a warning alarm if a fire condition is detected. Good fire detection depends on
having adequate numbers of smoke and heat detectors placed in appropriate locations. This
equipment should be installed in accordance with the relevant local authority fire
regulations. Carefully review the “Fire Escape Planning” guidelines in this manual.
Your installer must enable the fire detection feature before it will work.
Monitoring
This system is capable of transmitting alarms, troubles and emergency information over
telephone lines to an Alarm Receiving Centre (ARC). If you inadvertently initiate an alarm,
immediately call the ARC to prevent an unnecessary response.
Your installer must enable the monitoring function before it will work.

P0031-LU-01.00 5
Zones
A zone is an area of protection that has one or more detection devices connected to it
(motion detectors, glass-break detectors, door contacts or shock sensors). A single zone
might be a room, a hallway or a door or window.
Access Codes
The SEC8 control panel can have up to a total of 9 users. User 00 is the engineer and
cannot be accessed by the normal users. User 01 is the master user and has access to all
user menus. Users 02 to 08 default to “not in use” and can be assigned to the system either
by the engineer or master user.
As a user of the alarm system, you will be assigned a 4, 5 or 6 digit access code. Access
codes are used to arm and disarm the system. Some access codes can perform additional
system functions, such as programming system options, bypassing zones and performing
system tests.
Your access code may not allow you to access certain system functions. For instance, if your
code is only allowed to arm the system you will not be able to disarm the system, once the
system is armed.
Remote Keypads
One or more remote keypads will be installed throughout the protected premises, usually
close to the entry and exit door.
LED Keypad
The LED keypad features a dual 7 segment display for displaying zone status and system
fault messages. A set of dedicated system status LED’s for AC, Ready, Armed, Trouble,
Bypass, Alert and Alarm are also provided.
--
1
2
34

6 P0031-LU-01.00
LCD Keypad
The LCD keypad features a 2 x 20 character blue display for showing all zone status and
system fault messages. A set of dedicated system status LED’s for AC, Trouble and Alert are
also provided.
34
10:45 21/04/2011
Securacom SEC8
12
No Description
Display (LED or LCD)
LED Status Indicators
Number keys, start and hash
Function keys
LED Status Indicators
The LED status indicators are described below:
Icon Name LED Description
Power Green Mains AC power is present.
Ready Green The system is ready for arming.
Armed Green The system is armed (Away or Stay).
Fault Yellow
The system has one or more faults.
Bypass Yellow
One or more zones are bypassed.
Alert Red One or more faults/alarms require attention.
Alarm Red One or more alarms have occurred.

P0031-LU-01.00 7
Function Keys
The function keys are described below:
Key Description
A Away Arm
S Stay Arm 1
B Bypass
R Reset
Emergency Keys
The alarm system can provide three immediate emergency alarms by pressing and holding
the following keys for three seconds:
Event Press Keys
1and 3
4and 6
7and 9
The emergency keys can be individually enabled or disabled for each remote
keypad on your alarm system by the installer.
The Panic alarm (Police) can be individually programmed for either an audible or
silent operation for each remote keypad.

8 P0031-LU-01.00
2. Operating the Alarm System
Introduction
Before attempting to operate the alarm system ensure you have familiarised yourself with all
the procedures covered in this section.
User Menus
Once a valid user access code has been entered at any remote keypad, the user menu is
selected. The table below shows the user menu options and the command numbers used to
access them. All command with exception to the “Away Arm”, “Stay Arm 1” and “Reset” are
selected by entering their command number followed by *.
Group Command Function
Arming
A
S/1
2
3
Away Arm
Stay Arm 1
Stay Arm 2
Stay Arm 3
Reset R Reset alarm or fault
System Tests
11
12
13
Walk Test
Test Bell & Outputs
Do Test Call
Event Log & UDL
21
22
23
View Log
Print Log
Call UDL
Users 81 Chang code
Menus 91
99
Program Mode
Exit Menu
When using the LCD keypad the menu options and their command numbers are
scrolled on the bottom line of the LCD. If the *key is pressed, the menu option
that is currently being displayed is selected.
Only the Master user can access all options in the user menu.

P0031-LU-01.00 9
Before Arming the System
Before attempting to arm the system, ensure that all protected areas are secure by closing
any windows etc. If the system is not ready for arming the remote keypads scroll the zones
that are active. The “Ready” indicator on the LED remote keypad will also be off:
Zone 01: Active
Front Door
Zone 04: Active
Lounge Detector
Active zones are scrolled in sequence.
01
04
Ready off
Away Arm - A
The away arming mode is used for protecting all detection zones and is normally used when
leaving the premises unoccupied. Before arming the system check that the system is ready
for arming. To away arm your alarm system, please proceed as follows:
Ur
U er Menu
01: Stay Arm 1
Exit Now: 010
18:30 28/04/2011
Enter your access code .????
Press the Akey.
The display shows the remaining time
before the system is armed.
Sy tem Armed
18:31 28/04/2011
10
--
The system is now away armed.
Armed on
If the Quick Away Arm feature is enabled at the selected remote keypad, you may
omit step 1 from the above procedure.

10 P0031-LU-01.00
Stay Arm 1 - S
The stay arming mode is used for protecting some of the detection zones and is normally
used when the premises remain occupied. The system has three stay arm modes which
allow the system to be setup for three different protection scenarios. For example “Stay Arm
1” could be configured to provide perimeter protection only, whilst “Stay Arm 2” provides
perimeter and downstairs protection.
To stay arm your alarm system, please proceed as follows:
Ur
U er Menu
01: Stay Arm 1
Exit Now: 010
18:30 28/04/2011
Enter your access code .????
Press the Skey.
The display shows the remaining time
before the system is armed.
Perimeter Only
18:38 28/04/2011
10
--
The system is now stay armed.
Armed on
Bypass on
If the Quick Stay Arm feature is enabled at the selected remote keypad, you may
omit step 1 when performing a Stay Arm 1 from the above procedure.
Stay Arm 2 - 2*
This option allows you to select the second stay arm mode. Follow the procedure for stay
arm 1 (above), and enter 2* at step 2.
Stay Arm 3 - 3*
This option allows you to select the third stay arm mode. Follow the procedure for stay arm 1
(above), and enter 3* at step 2.
Other manuals for SEC8
1
Table of contents
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual