Seca 745 Instruction Manual

seca 745
seca 725

Bedienungsanleitung und Garantieerklärung . . . . . . . . . . 3
Instruction manual and guarantee . . . . . . . . . . . . . . . . . . 25
Mode d’emploi et garantie. . . . . . . . . . . . . . . . . . . . . . . . . 45
Manuale di istruzioni e garanzia . . . . . . . . . . . . . . . . . . . . 67
Manual de instrucciones y garantia . . . . . . . . . . . . . . . . . 89
Instruções de utilização e declaração de garantia . . . . . 111
Instrukcja obsługi i gwarancja . . . . . . . . . . . . . . . . . . . . 133
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . 155
D
GB
FR
IT
ES
P
PL

• 25
English
CONTENTS
English
1. Full certification . . . . . . . . . . . . . 26
2. Description of device . . . . . . . . . 26
2.1 Congratulations! . . . . . . . . . . . 26
2.2 Intended use . . . . . . . . . . . . . . 27
2.3 Description of function . . . . . . 27
2.4 User qualification . . . . . . . . . . 27
3. Safety information . . . . . . . . . . . . 28
3.1 Safety information in these
instructions for use . . . . . . . . . 28
3.2 Basic safety precautions . . . . . 28
Handling the device . . . . . . . . 28
Avoiding infections . . . . . . . . . 29
Avoiding injury . . . . . . . . . . . . 29
Avoiding damage to the
device . . . . . . . . . . . . . . . . . . . 29
Handling the measurement
results . . . . . . . . . . . . . . . . . . . 30
Handling the packaging
material . . . . . . . . . . . . . . . . . . 30
4. Overview . . . . . . . . . . . . . . . . . . . 31
4.1 Controls . . . . . . . . . . . . . . . . . 31
4.2 Information on device and
on rating plate . . . . . . . . . . . . . 32
4.3 Information on the
packaging . . . . . . . . . . . . . . . . 32
5. Before you get started … . . . . . . 33
5.1 Scope of supply . . . . . . . . . . . 33
5.2 Remove transport lock . . . . . . 33
5.3 Put on tray . . . . . . . . . . . . . . . 34
5.4 Set up and align scale . . . . . . . 34
6. Operation . . . . . . . . . . . . . . . . . . . 35
6.1 Rendering the scale
operational . . . . . . . . . . . . . . . 35
Releasing/locking the beam . . 35
Checking the position of
the beam . . . . . . . . . . . . . . . . 35
Balancing the beam . . . . . . . . 36
6.2 Weighing . . . . . . . . . . . . . . . . 37
Performing a weighing
operation . . . . . . . . . . . . . . . . 37
Taring additional weight . . . . . 38
7. Hygiene treatment . . . . . . . . . . . 39
7.1 Cleaning . . . . . . . . . . . . . . . . . 39
7.2 Disinfecting . . . . . . . . . . . . . . . 39
7.3 Sterilisation . . . . . . . . . . . . . . . 39
8. Function check . . . . . . . . . . . . . . 40
9. What do I do if …? . . . . . . . . . . . 41
10. Servicing/subsequent
verification . . . . . . . . . . . . . . . . . 41
10.1 Information on servicing
(seca 725) . . . . . . . . . . . . . . 41
10.2 Information on servicing and
subsequent verification
(seca 745) . . . . . . . . . . . . . . 42
11. Technical data . . . . . . . . . . . . . . 42
11.1 General technical data . . . . . 42
11.2 Weighing data . . . . . . . . . . . 43
12. Disposal . . . . . . . . . . . . . . . . . . . 43
13. Warranty . . . . . . . . . . . . . . . . . . 44

26 •
1. FULL CERTIFICATION
With seca products, you are not only purchasing tech-
nology which has been perfected over 100 years, but
also quality with official legal certification confirmed by
institutions. seca products comply with European
directives, standards and national laws. When you buy
seca, you buy the future.
seca’s professionalism is also recognized by official
testing agencies. TÜV SÜD Product Service, the
appointed office for medical devices, confirms with this
certificate that as a medical devices manufacturer,
seca consistently complies with the strict legal require-
ments. seca’s quality assurance system includes the
areas of design, development, production, sales and
service of medical scales and length measuring sys-
tems as well as software and measuring systems for
assessing state of health and nutrition.
seca helps the environment. Saving natural resources
is very important to us. We therefore make every effort
to save on packaging materials wherever it makes
sense and whatever is left over can be conveniently
disposed of on site via the recycling system.
2. DESCRIPTION OF DEVICE
2.1 Congratulations!
By purchasing this mechanical baby scale you are now
in possession of an extremely accurate yet robust
device.
seca has put its experience at the service of health care
for over 170 years and as a market leader in many
countries, is constantly setting new standards with its
innovative developments for weighing and measure-
ment.

Description of device • 27
English
2.2 Intended use
The seca mechanical baby scale is mainly used in hos-
pitals, doctors' surgeries and inpatient care facilities in
accordance with national regulations.
The scale is both for determining birth weight and
checking weight gain during the growth process, and it
supports the doctor supervising treatment in making a
diagnosis or deciding on a treatment.
In order to make a precise diagnosis, however, other
specific examinations must be set up by the physician
in addition to determination of weight and their results
taken into account.
2.3 Description of function
On mechanical scales, weight is determined by a load
lever system. To display the weight, the user moves
two sliding weights on a beam until the beam is
balanced. The patient's weight can then be read off at
the position of the sliding weights.
Use the scale only for the purpose quoted in the
section entitled “Intended use”.
2.4 User qualification
The device may only be operated by healthcare
professionals.

28 •
3. SAFETY INFORMATION
3.1 Safety information in these instructions for use
DANGER!
Used to identify an extremely hazardous situa-
tion. If you fail to take note of this information,
serious irreversible or fatal injuries will occur.
WARNING!
Used to identify an extremely hazardous situa-
tion. If you fail to take note of this information,
serious irreversible or fatal injuries may result.
CAUTION!
Used to identify a hazardous situation. If you fail
to take note of this information, minor to moder-
ate injuries may result.
NOTICE!
Used to identify possible incorrect usage of the
device. If you fail to take note of this information,
you may damage the device, or the measured
results may be incorrect.
NOTE
Includes additional information about use of the
device.
3.2 Basic safety precautions
Handling the device • Please take note of the information in these instruc-
tions for use.
• Keep the instructions for use in a safe place. The
instructions for use are a component of the device
and must be available at all times.
CAUTION!
Patient hazard, damage to device
• Have servicing and subsequent verification
carried out regularly as described in the rele-
vant section of this document.
• Technical modifications may not be made to
the device. The device does not contain any
parts for servicing by the user. Only have serv-
icing and repairs performed by an authorized

Safety information • 29
English
seca service partner.
• Only use original seca accessories and spare
parts, otherwise seca will not grant any
warranty.
Avoiding infections WARNING!
Risk of infection
• Hygienically reprocess the scale regularly as
described in the respective section in this
document.
• Make sure that the patient has no infectious
diseases.
• Make sure that the patient has no open
wounds or infectious skin alterations, which
may come into contact with the device.
Avoiding injury WARNING!
Risk of falling
Baby scales generally stand on raised work sur-
faces. If the baby falls from this surface, this
may result in serious irreversible or fatal injuries.
– Ensure that the device is steady and level.
– Route connecting cables (if present) in such a
way that people cannot trip over them.
– Never leave a baby unsupervised.
Avoiding damage to the
device
NOTICE!
Damage to device
• Make sure not to drop the device.
• Do not expose the device to any impact or
vibration.
• Perform function controls regularly as
described in the relevant section in this docu-
ment. Do not operate the device if it is dam-
aged or not working properly.
• Caustic detergents may damage the surfaces.
Only use a soft cloth dampened with mild
soapsuds to clean the surfaces of the device.
• Only use disinfectants suitable for sensitive
surfaces. Suitable disinfectants are available
from specialist dealers.

30 •
Handling the
measurement results
WARNING!
Patient hazard
This device is no diagnostic device. It simply
assists the treating physician in establishing a
diagnosis.
– In order to make a precise diagnosis and
initiate therapeutic measures, besides
determination of the weight, further targeted
examinations must be set up by the
physician, and their results must be
considered.
– The responsibility for diagnosis and treatment
lies with the treating physician.
NOTICE!
Inconsistent measuring results
• Before you save measurement values deter-
mined using this device and use them further
(e.g. in seca PC software or in a hospital infor-
mation system), make sure that the measure-
ment values are plausible.
• If measurement values are transmitted to seca
PC software or a hospital information system,
make sure prior to further use that the meas-
urement values are plausible and are assigned
to the correct patient.
Handling the packaging
material
WARNING!
Risk of suffocation
Packaging material made of plastic foil (bags) is
a choking hazard.
– Keep packaging material out of reach of
children.
– In the event that the original packing material
may not be available anymore, only use
plastic bags with security holes in order to
reduce the risk of suffocation.
NOTE
Keep the original packing material for future use
(e.g. returning for maintenance service).

Overview • 31
English
4. OVERVIEW
4.1 Controls
seca 745/725:
1
3
7
8
9
10 11
6
4
2
5
No. Control Function
1Large sliding weight
Can be moved to set the weight display roughly
• Pull forward: release sliding weight
• Release: lock sliding weight in position
2Small sliding weight Can be moved to set the weight display
accurately
3Tare weight with
knurled screw
Can be moved to balance the beam
• On initial use and before every weighing
operation
• To tare off an additional weight
4Fine-tare screw
Can be adjusted to balance the beam exactly
• On initial use and before every weighing
operation
• To tare off an additional weight
5Tray Where the baby is placed
6Locking lever
•2pcs
• For locking the tray in position on the scale
housing
7Pointer and counter-
pointer Indicate whether the beam is balanced
8Beam with scale For reading off the weight
9Locking lever
For locking/releasing the beam
• Push down: lock in position
• Raise: release

32 •
4.2 Information on device and on rating plate
4.3 Information on the packaging
10 Spirit level Indicates whether the device is horizontal
(verified models)
11 Device feet
•4pcs
• Adjustable to align the scale accurately
(verified models)
No. Control Function
Text/symbol Meaning
Model Model number
Ser. No. Serial number
Follow instructions for use
Conformity label according to Directive 2009/23/EC gov-
erning non-automatic weighing instruments (verified
models)
eValue in mass units used for classifying and for verifying
the scale (verified models)
dValue in mass units indicating the difference between the
values of two adjacent increments
TMarks the zero position of the tare weight. Visible when
tare weight is moved out of zero position.
Scale of verification class III as per Directive 2009/23/EC
Device complies with EC standards and directives.
•xx: Year in which EC verification was carried out and
the CE label was affixed (verified models)
• 0109: Notified body, metrology: Hessen Weights &
Measures Office [Hessische Eichdirektion, Germany]
(verified models)
•0123: Notified body, medical devices:
TÜV SÜD Product Service
xx
0109
0123
Protect from moisture
Arrows indicate top of product.
Transport and store in an upright position.
Fragile
Do not throw or drop.
Other manuals for 745
3
This manual suits for next models
1
Table of contents
Other Seca Scale manuals