Sagitter HYP006WW User manual

1
LIGHT( C+W)
USER MANUAL
LED WASH

2
1.BEFORE YOU BEGIN
What is included
Ø1 x Fixture
Ø1 x Powercable with plug
Ø1 x UserManua
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton; check the
contents to ensure that all parts are present, and have been received in good
condition. Notify the shipper immediately and retain packing material for
inspection if any parts appear damaged from shipping or the carton itself shows
signs of mishandling. Save the carton and all packing materials. In the event that
a fixture must be returned to the factory, it is important that the fixture be returned
in the originalfactory box andpacking.
AC POWER
This fixture hasan auto-switching switch-modepower supply thatcan
accommodate a widerange of inputvoltages. The only thing necessaryto do
before powering onthe unit isto make surethe line voltageyou are applyingis
within the rangeof accepted voltages.This fixture will accommodate between
100V and 240VAC 50-60Hz. Each lightis connected endto end bythe power
socket “POWER IN”and “POWER OUT”on the light,or use thewaterproof power
cord. Please ensurethe head andthe tail tighteningwhen connect thelights, to
prevent the powerleakage occurred bywater seepage tothe plug.
Help preserve theenvironment! Ensure thatthis product is
recycled at theend of itslife. Your supplier cangive details
of local arrangementsfor the disposalof products.

3
Safety Instructions
!
WARNING!
Please read theseinstructions carefully, which includes
important information aboutthe installation, usageand
maintenance of thisproduct..
The following symbols are used to identify important safety information on the
product and inthis manual:
!!
DANGER!
Safety hazard.
Risk of severe
injury or death
DANGER!
Hazardous
Voltage. Riskof
lethal or severe
electric shock.
WARNING!
Fire hazard
WARNING!
LED light
emission. Risk
of eye injury.
WARNING!
Refer to user
=This light belongsto grade Iprotection device, thereforethe light mustconnect
to the earthexcellently. And thepower connection mustbe operated bythe
professional technician.
=Make sure thatthe working voltagewill not higheror lower thanthe rated value.
=Make sure thatthe cable didn'tbe damage orlacerated by sharp.
=The light mustbe power off when it's standing idle or before clearing.
=The cable mustwith plug, andyou must pullout the cableby handle theplug.
=Please be carefulwhen installing thelighting. Never touchthe bared cable,or
it will causethe deadly electricshock.
=Please use thesuitable and safecable to connectthe light.
=Please never remodelthe light randomly, we willnot take theguarantee for the
faulty and damagewhich caused bydismantle repair or remodelof the
nonprofessional person.
=Maximum ambient temperature40°C. Do notoperate fixture attemperatures
higher than this.
=Never connect thedevice to adimmer pack.
=Do not daisychain power tomore than 8units @ 120Vand 15 units@ 230V.

4
2.INTRODUCTION
Specifications
lVoltage Rating: AC100V 240V 50-60Hz
lPower Rating: 90W
lLED Quantity: 36psc LEDs(18cool white+18warmwhite)
lLED: 670mA
lBeam Angle: 20°/30°/40°(option)
lIngress Protection: IP65/indoor(option)
lProduct Size: 255x 205 x290mm
lPackage Size: 315x280x345mm
lN/W:4.0Kg
Features
lColor Temperature: 2800K~5900K (Adjustable)
lCRI: >90Ra
l5 distinct dimming curves
lLED display with password protection
Operating Modes: DMX512Connection /Master &Slave...
lDMX Channels: 02CH,03CH,07CH
2 channelS:Dimmer+ whiteCT Macro
3 channels: Dimmer+coolwhite + warmwhite
7 channels:Dimmer+cool white+ warm white+whiteCT macro + strobe
+Dimmer speed +ID Address

5
Product Overview
Power in Power out
DMX IN DMX OUT
Control board
Safety
Dimensions
Hanging
bracket/ floor
stand
Bracket
adjustment
knob
290

6
3.SETUP
Installation Requirement
lThis product can be used in a variety of situations, can hang and put on
the ground.
lIf hanging the fixture for over head use,then please followthe below steps.
lPlease choose thesuitable location toput or hangthe light wheninstalling it.
Youmust use the exclusive clamp hanger and screw when hanging it, and
make sure the weight of the light is within limits of the hanger.
lPlease make sure without any flammable objects within 0.5m when
installing the light.
lThe installation should be operated by professional person; any irregular
installation will cause the body injury or equipment damage.
lBlock access belowthe work areaand use suitable and stable platform
when installing or servicing fixture.
Hanging Clamp
Note: sold
separately
Safety Cable
Note: the cablemust be
secured through the heat
sink ventilation
passageway.

7
Connection of DMX Signal Wire
1Please use the fixture controller wire specially when use the DMX512
Controller. Connectthe (male) 3pin connector side of the DMX cable to
the output (female) 3 pinconnector of the first fixture.
2Connect the endof the cable coming fromthe first fixture which willhave
a (male) 3pin connector tothe input connectorof the next fixture
consisting of a (female) 3 pin connector. Then, proceed to connect from
the output asstated above tothe input ofthe following fixture and so on.
3This product can be connected numerous lamps in series without the
need for the signal amplifier; the signal will not be weakened.
DMX IN DMXOUT DMX IN DMXOUT DMX IN DMXOUT
3-PIN TO 5-PIN CONVERSION CHART
Note! If you use a controller with a 5 pin DMX output connector, you will
need to usea 5 pinto 3 pinadapter.
Conductor
Ground/Shield
Data ( -) signal
Data ( +) signal
Do not use
Do not use
3 Pin Female(output)
Pin 1
Pin2
Pin 3
5 Pin Male(Input)
Pin 1
Pin2
Pin 3
Do not use
Do not use
3 PIN TO 5 PIN CONVERSION CHART

MAIN
FUNCTION
SUB-
FUNCTION SELECTION
000~255
(0 ~ 100%)
00~20
01~03
001~512
07CH
02CH
03CH
ON~OFF
ON~OFF
OFF
DIM1/2/3/4
Password
1.31
INSTRUCTION
Select strobe frequency
3 auto programsavailable
Set DMX startaddress
Sets the operatingmode for the
fixture:to receive signalfrom a DMX
controller (DMX) .receivesignal from
Master fixture. (Slave)
Assign ID addressfor fixtures
Enable or disableID
Enables or Disablespassword lockout
"Off" meansselect linear dimming,or
choose dimmer 1-4to control thedimming
speed, dimming 1of the fastestdimming
curves, 4 forthe most slowlydimming curve
Reset factory defaults
Version number
User can combineCool White, Warm
White to generatea custom color
7CHS: D+C+W...
2CHS: Dimmer+CCT
3CHS: Dimmer+C+W
Preset custom whites
Can choose different color
temperature
01~66
2800
3000
3200
3400
4200
4900
5600
5900
4.OPERATING INSTRUCTIONS
Menu Map
8

9
Control Panel Functions
BUTTON
MODE
ENTER
UP
DOWN
FUNCTION
Exits from thecurrent menu or function
Enables the currently displayed menu or sets the currently selected
value in tothe selected function
Navigates upwards through the menu list and increases the numeric
value when ina function
Navigates downwards through the menu list and decreases the numeric
value when ina function
Operating instructions
1 Enable password lock
Ü ÜON / OFF Ü{ENTER}
ON enable lock OFF disable lock
Enable the passwordlock, control panel in the boot or go into standby automatically
take effect, this time tooperate lamps needto enter yourpassword. { MODE UP
MODE DOWN MODE UP MODE DOWN }Ü{ENTER}
2 Factory reset
ÜÜ{UP UP DOWN DOWN}Ü{ENTER}
Note: The password is permanentlyset as {UP UP DOWN DOWN}
Then press ENTERbutton

10
DMX512 Controller Mode
1 DMX operate mode setting
Access control panelfunction by pressingMODE until is displayed.
Press ENTER, pressUP/DOWN buttons until the is displayed.
Press ENTER, PressMODE return to MENU
2 Setting DMX512 Address
Ü001--512
Access control panelfunction by pressingMODE until is displayed.
Press ENTER, addor reduce channelsby pressing UP/DOWNbetween 001 and512.
Press MODE toexit.
3 Setting Channels
Ü07CH 02CH 03CH
Access control panelfunction by prekssing MODE until is displayed.
Press ENTER button,select DMX channel by pressing UP/DOWN,
Press MODE toexit.
02 channels
Channel
1 Dimming
2 CCT
Value
000~255
~
~
~
~
~
~
~
~
000 010
011 040
041 070
071 100
101 130
131 160
161 190
191 220
221~255
Description
0-100%
No Function
White 1: 2800K
White 2: 3000K
White 3: 3200K
White 4: 3400K
White 5: 4200K
White 6: 4900K
White 7: 5600K
White 8: 5900K
NOTE: Channel 1 controls the intensity of the currently projected white color, when
the slider is at the highest position (255), then the intensity of the output is at the
maximum.