4RiLine Compact Motor Controller Assembly and operating instructions
2. Notes on documentation
The assembly instructions are aimed at personnel who are suitably trained and qualified to configure enclosures with electrical,
electronic, mechanical and pneumatic equipment in accordance with applicable standards and to erect, assemble and connect
such enclosures at the place of use.
The operating instructions are aimed at operating personnel and suitably trained electrical and mechanical maintenance special-
ists.
2.1 CE labelling
The declaration of conformity is available for downloading at www.rittal.com.
2.2 Storing the documents
The safety instructions constitute part of the product, and must be handed to the plant operator. The operator is responsible for
suitable storage of the documents so they are readily available when needed.
2.3 Symbols used
Please observe the following safety instructions and other notes in these instructions:
2.4. Associated documents
These installation and operating instructions for the busbar components described here can be downloaded from www.rittal.com.
Rittal cannot accept any liability for damages associated with the failure to observe these instructions. The instructions for any
accessories used also apply.
Danger!
Immediate danger to life and limb.
Caution!
Potential threat to the product and the environment.
Note!
Useful information and special features.
3. Safety provisions / set-up instructions
• The national safety and accident prevention regulations must be observed whenever working on the device. Failure to observe
these regulations may result in death, serious injury or considerable material damage.
• The product documentation / instructions for use must be kept in a safe place.
• If using "automatic RESET" mode, the drive will be reactivated once the cooldown period has elapsed, provided a control signal
is still present. The cooldown period is 20 minutes.
• Installation should be performed in accordance with the operating instructions provided. Access to the circuits inside the appli-
ance is inadmissible.
• Opening or modifying the appliance and carrying out repairs yourself will invalidate the warranty. The device will be replaced
under warranty with an equivalent appliance. Repairs may only be carried out by the manufacturer. The manufacturer will not be
liable for any damages caused by a contravention of this provision.
• The safety data can be taken from this documentation and the certificates.
• When the drive is switched on and/or in the deactivated state, the device performs a function diagnosis. Additionally, an electri-
cian or specialist who is familiar with the relevant standards may carry out a test of the "motor protection" safety function. For
this test, the drive must be operated in counter-clockwise or clockwise mode and the flow of electricity interrupted in one con-
ductor (e.g. by removing a fuse in phase L1 or L3). The motor controller will then switch o the drive within 1.5 .. 2 s. The LEDs
for counter-clockwise or clockwise rotation will be extinguished and the ERR-LED and checkback output will be set.
• Only power packs with reliable disconnection with SELV/PELV voltage to EN50178/ VDE 0160 (SELV/ PELV) should be used.