Rinstrum axleWEIGHr User manual

(L003-507)
Reference Manual

Copyright
All Rights Reserved. No part of this document may be
copied, reproduced, republished, uploaded, posted,
transmitted, distributed, stored in or introduced into a
retrieval system in any form, or by any means (electronic,
mechanical, photocopying, recording or otherwise)
whatsoever without prior written permission of Rinstrum
Pty Ltd.
Disclaimer
Rinstrum Pty Ltd reserves the right to make changes to
the products contained in this manual in order to improve
design,
performance or reliability.
The information in this manual is believed to be accurate
in all respects at the time of publication, but is subject to
change without notice. Rinstrum Pty Ltd assumes no
responsibility for any errors or omissions and disclaims
responsibility for any consequences resulting from the use
of the information provided herein.
SPECIAL NOTE
Trade Use of the Instrument
This manual may occasionally make reference to
Trade Use settings of the instrument.
Some individual settings may not be legal for trade use.
Please check regulations with the appropriate
Weights and Measures Authority.

Operator Manual Rev 2.01
L003-507-V1.2.1 Page 1
Table of Contents – Category Logger App L003-507
1. OVERVIEW ........................................................................................................................... 2
1.1. Overview .................................................................................................................... 2
1.4. User Interface & Display ............................................................................................. 3
1.5. Display & Annunciators .............................................................................................. 4
1.7. Keypad ....................................................................................................................... 5
1.9. Turning Instrument on ................................................................................................ 6
1.11.1 Wiring & Connections ................................................................................................. 7
1.12. Zero Key ..................................................................................................................... 8
1.13. Dynamic Scale, Creating & Setting up Trucks ............................................................ 9
1.14. Setting Time & Date ................................................................................................. 10
1.15. Stability .................................................................................................................... 11
1.16. Traffic Lights……………………………………………………………………………… 12
1.17 Clicker Operation ...................................................................................................... 13
1.18. USB Operation ......................................................................................................... 14
1.19. Printer Operation…………………………………………………………………………..
2. SETTING UP TRUCKS ....................................................................................................... 15
1.20. Truck Weighing ........................................................................................................ 16
1.21. Function Key Operations .......................................................................................... 17
1.22. Setting up CSV Data-base ................................................................................... 18-21
1.23. Data log output ......................................................................................................... 22
3. ERROR MESSAGES ........................................................................................................... 23
1.24. Overview .................................................................................................................. 23
1.25. Weighing Errors ........................................................................................................ 23
1.26. F2 Configuration Menu Defined................................................................................ 24
1.27. Definitions & Special Settings Menu .................................................................... 25-26

Operator Manual Rev 2.01
Page 2 AXLE-613-201
Overview and Safety
1.1. Overview
This precision digital indicator uses advanced firmware and the LUA module to perform
axle weighing. The category logging program records truck weights to a database for
later recovery using a USB drive. There is a soft power on/off function that retains
memory of its state. Once an instrument is turned on it will automatically start up again
if the external power is interrupted. Day-to-day settings (Clock, Trucks, and Pre-set
Tares etc.) are retained when power is removed.
The instrument provides zero, truck and re-print on the fixed function keys and supports
special functions (farm/field setup, 1 key access to configuration menu.), via function
key and remote inputs (clickers). The up/down arrow and [ok] keys are used in most
menus to make selections.
There are various features written into the LUA module that are very useful for this
specific application. The discard timer allows for weighing first then setting up the truck
id. The farm configuration data can be setup to individual trucks for unique data-basing
options.
Many of the features and functions described in this manual may not be available in all
versions of the axleWEIGHr. Due to variations in Firmware and various applications not
all features described in this manual may work as described.
1.2. Operating Environment
Temperature: 14 °F to 122 °F (–10 to +50°C ambient)
Humidity: <90% non-condensing
Storage: –20 to +50°C ambient (-4 °F to 122 °F)
IP66 panel mounted
1.3. Electrical Safety
For your protection all mains electrical hardware must be rated for environmental
conditions of use.
Pluggable equipment must be installed near an easily accessible power socket outlet.
To avoid the possibility of electric shock or damage to the instrument, always unplug or
isolate the console from the power supply before maintenance is carried out.
1.4. Cleaning
To maintain the instrument, never use harsh abrasive cleaners or solvents. Wipe the
instrument with a soft cloth slightly dampened with warm soapy water.

Operator Manual Rev 2.01
L003-507-V1.2.1 Page 3
User Interface and Display
Code Description
1 Display
2
Numeric Keypad
3
Function Keys (Fixed)
4 Power Key

Operator Manual Rev 2.01
Page 4 AXLE-613-201
1.5. Display
Code Description
1
Primary Annunciators
2
Primary Display
3 Auxiliary Display (WO or WO-PT)
4
Primary Units
5
Category prompt: example
Farm
6
Miscellaneous Annunciators
7 Secondary Units
(function not available)
8
Secondary
Display
(totalised weight of last truck)
1.6. Primary Annunciators
Symbol Name Description
HOLD Visible when the displayed reading is held.
NET Visible when the displayed reading represents Net
weight.
ZERO Visible when the gross reading is within
¼ of a
division of true zero.
MOTION Visible when the displayed reading is not stable.
ZERO BAND Visible when the displayed weight is within the zero
'dead' band setting.

Operator Manual Rev 2.01
L003-507-V1.2.1 Page 5
1.7. Keypad
See FUNCTION KEYS (pg. 13)
1.8. Strings
To enter custom names via the keypad press the number keys repeatedly and the
characters will scroll through. For example pressing the #2 key twice will produce a “B”.
If you wait 2 seconds and press the #2 key again you can enter an “A”.
Normal String Editing
Normal string editing is most useful where strings are small and contain no lowercase
or unprintable characters. The available characters are printed in orange on the
keypad.
Code Description
1 Number Buttons 0-9 (short press)
2 Black Characters Hold 2 seconds (#1 key allows time & date
configuration)
3 Orange Characters [F1]-[F3]*
Cancel Undo last command; step backwards (including
in setup menus).
Up Move cursor backwards; previous option
(use for trucks & farm/field selections)
Down Move cursor forwards; next option
(use for trucks & farm/field selections)
OK Accept this choice
Decimal Point Place decimal point

Operator Manual Rev 2.01
Page 6 AXLE-613-201
Special keys are:
<OK>: Accept changes and finish.
<Long press of cancel>: Cancel and exit without changes
<Cancel>: Delete character
<Up>, <Down>: Move cursor
<Long press of down>: Delete string after cursor
<+/->: Switch editing modes
1.9. Turn Instrument ON - Short press <Power>
1.10. Turn Instrument OFF - Long press <Power>

Operator Manual Rev 2.01
L003-507-V1.2.1 Page 7
1.11. Wiring & Connections
Make connections using the supplied AC Power cord terminating the Grey Green and
White wires as shown below. 110 VAC - 240 VAC accepted
AC POWER MAIN CONNECTIONS
Grey Terminal – Black (HOT)
Connector 1 – Scale Cable (5 pin)
White Terminal – White (Neutral) Connector 2 – Remote Display
Green Terminal – Green (Ground) Connector 3 – Clicker RF Box
Optional: Connector 4—Sensor Cable I/O
*Figure 2: Connector #4 is used in some applications for optional accessory (sensors, external
lights, etc.)

Operator Manual Rev 2.01
Page 8 AXLE-613-201
1.12. Zero Key
When an empty scale has drifted away from a true zero reading, this key is
used to perform a zero adjustment on the scale display. The zero
adjustment is stored when power is removed and is re-used when next
powered up.